6
2
Delivery Set
Smoke Exhauster H-0220 Delivery Set includes:
Table 2 – Smoke Exhauster Delivery Set.
Smoke Exhauster
-1 ea.
Fan R2e160-BG34-01
-1ea.
Stainless rods
-2 ea.
Heat-resistant gasket
-1 ea.
3
Operation Concept
The Smoke Exhauster H-0220 is connected to the control unit, and this
control unit controls the smoke exhauster operation process. The Smoke Exhauster
is equipped with a blower of hot air circulation of R2e160-BG34-01AC current
what allows operating the unit easily.
4
Safety Measures
Prior to carrying out of any actions associated with the smoke exhauster
clean-up or maintenance make sure that the unit is de-energized.
And in addition, turn off the heating equipment to exclude flow of flue gases
in the chimney flue.
5
Installation
The Smoke Exhauster is mounted into the chimney flue of the corresponding
diameter. A hollowing is done in the chimney flue in accordance with dimensions
described in the Operation Manual or along the outline of stencil mask indicated in
the Operation Manual (111 (across the flue) :376 mm (along the flue)). Further, the
smoke exhauster outline that has a contact with the chimney flue is treated with
heat-resistant sealant material according to the rules mentioned by the
manufacturing plant and mounted into the hole with tightening tightly and sealing
the contact with a clamp.