background image

THREE (3) YEAR LIMITED WARRANTY

BioOx Reactor 85

 of 

4

15

For the BioOX Reactor product line only 

IMPORTANT: BY USING YOUR BIOOX REACTOR UNIT YOU ARE AGREEING TO BE BOUND BY THE 
TERMS OF THE BIOOX THREE (3) YEAR LIMITED WARRANTY (“WARRANTY”) AS SET OUT BELOW. DO 
NOT USE YOUR PRODUCT UNTIL YOU HAVE READ THE TERMS OF THE WARRANTY. IF YOU DO NOT 
AGREE TO THE TERMS OF THE WARRANTY, DO NOT USE THE PRODUCT AND RETURN IT WITHIN THE 
RETURN PERIOD STATED IN BIOOX'S RETURN POLICY TO THE AUTHORIZED DISTRIBUTOR WHERE 
YOU PURCHASED IT FOR A REFUND. 

HOW CONSUMER LAW RELATES TO THIS WARRANTY 

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY HAVE OTHER RIGHTS THAT VARY FROM STATE 
TO STATE (OR BY COUNTRY OR PROVINCE). OTHER THAN AS PERMITTED BY LAW, BIOOX DOES NOT EXCLUDE, LIMIT 
OR SUSPEND OTHER RIGHTS YOU MAY HAVE, INCLUDING THOSE THAT MAY ARISE FROM THE NONCONFORMITY OF A 
SALES CONTRACT. FOR A FULL UNDERSTANDING OF YOUR RIGHTS YOU SHOULD CONSULT THE LAWS OF YOUR 
COUNTRY, PROVINCE OR STATE. 

WARRANTY LIMITATIONS SUBJECT TO CONSUMER LAW 

TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE REMEDIES SET FORTH ARE EXCLUSIVE AND IN LIEU 
OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL, WRITTEN, STATUTORY, EXPRESS OR 
IMPLIED. BIOOX DISCLAIMS ALL STATUTORY AND IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN 
OR LATENT DEFECTS, TO THE EXTENT PERMITTED BY LAW. IN SO FAR AS SUCH WARRANTIES CANNOT BE 
DISCLAIMED, BIOOX LIMITS THE DURATION AND REMEDIES OF SUCH WARRANTIES TO THE DURATION OF THIS 
EXPRESS WARRANTY AND, AT BIOOX'S OPTION, THE REPAIR OR REPLACEMENT SERVICES DESCRIBED BELOW. SOME 
STATES (COUNTRIES AND PROVINCES) DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY (OR 
CONDITION) MAY LAST, SO THE LIMITATION DESCRIBED ABOVE MAY NOT APPLY TO YOU. 

WHAT IS COVERED BY THIS WARRANTY? 

Air & Water Solutions Inc. of P.O. Box 627, Nutley, New Jersey, U.S.A. 07110 (“Air & Water Solutions”) warrants the BioOx-
branded Reactor hardware product and the BioOx branded accessories contained in the original packaging against defects in 
materials and workmanship when used normally in accordance with BioOx's published guidelines for a period of THREE (3) 
YEARS FOR THE REACTOR HOUSING AND 90-DAYS FOR THE FANS AND PUMPS from the date of original retail purchase 
by the end-user purchaser ("Warranty Period"). BioOx's published guidelines include but are not limited to information 
contained in technical specifications, user manuals and service communications. 

Содержание Reactor 300

Страница 1: ...Reactor 85 300 650 E MANUAL Air Water Solutions Inc P O Box 627 Nutley New Jersey 07110 301 246 0151 www bioox us ...

Страница 2: ...BioOx Reactor 85 of 2 15 ...

Страница 3: ...NERAL INFORMATION 7 TECHNICAL SPECIFICATIONS 8 UNIT OVERVIEW PARTS NAMES 9 OPERATING PROCEDURE 10 DOSAGE SCHEDULE 11 ADDING BIOOX NATURAL MEDIA 12 MAINTAINING YOUR UNIT 12 TROUBLESHOOTING FOR THE BIOOX CLEAN AIR SYSTEM 14 PREPARING FOR AN EXTENDED LEAVE 14 CONTACT INFORMATION 15 BioOx Reactor 85 of 3 15 ...

Страница 4: ...ONDITIONS WHETHER ORAL WRITTEN STATUTORY EXPRESS OR IMPLIED BIOOX DISCLAIMS ALL STATUTORY AND IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS TO THE EXTENT PERMITTED BY LAW IN SO FAR AS SUCH WARRANTIES CANNOT BE DISCLAIMED BIOOX LIMITS THE DURATION AND REMEDIES OF SUCH WARRANTIES TO T...

Страница 5: ...R THIS WARRANTY NULL AND VOID Before receiving warranty service BioOx or its agents may require that you furnish proof of purchase details respond to questions designed to assist with diagnosing potential issues and follow BioOx s procedures for obtaining warranty service Before submitting your BioOx Product for warranty service please contact us at 301 246 0151 HOW DO I OBTAIN WARRANTY SERVICE Pl...

Страница 6: ...o not operate unit on wet surface Never handle the pump or fan motor plugs and cords with wet hands or when standing on wet surface 11 During operation maintain the water level of the tank Water level should not be allowed to go below water pump level If there is not enough water to circulate in the reservoir the pump may be damaged and the cleaning efficiency reduced Maintain water level between ...

Страница 7: ...ow leaks spills or floods The BioOx 85 is an air cleaning unit which biologically oxidizes organic chemicals and contaminants and removes dust and other particles from the air This unit is specially designed for the removal of indoor air pollutants The BioOx 85 has been pre loaded with BioOx Natural Media biomass which are able to eliminate a broad spectrum of organic pollutants as their carbon so...

Страница 8: ...Container Vol G 10 G Rating AC 110V 60HZ Power consumption 24 Watts Dimensions D x H 13 D x 25 H Noise levels 34 db Dry Weight 16 lbs External dimensions are approximate In extremely high altitudes or severely cold areas the product may not perform as specified Avoid using product in such areas or in other extreme conditions This product is not suitable for use in countries or regions with differen...

Страница 9: ... Reactor 85 of 9 15 Air Water Inlet Tray Fan fan assembly Water Reservoir Tank Water Pump Unit Inside Unit Tee connection Pump disconnect fitting Water recirculation tray BioStack cartridge core pipe Pump sits at bottom of reservoir ...

Страница 10: ...the fan cord into the electric outlet 120 volts Place hand near fan making sure air is flowing out The BioOx 85 should now be operating automatically 3 Maintain the water level above the water pump and between the Minimum and Maximum Water Level Lines at all times 4 Check water level daily Add water periodically to maintain water level Allowing the water level to get too low will damage the pump 5...

Страница 11: ...dia Initial Dosage BioOx Media Monthly Dosage BioOx Media Monthly COVID Dosage BioOx 85 250ml 125 ml month 250 ml month BioOx 300 600 ml 250 ml month 500 ml month BioOx 650 1250 ml 500 ml month 1000 ml month BioOx 5000 3000 ml 1000 ml month 2000 ml month Weekly Dosages Recommended WARNING Choose either WEEKLY or MONTHLY routine DO NOT USE BOTH PLEASE MAKE SURE TO ONLY FOLLOW THE SCHEDULE FOR YOUR ...

Страница 12: ...low reservoir when adding with water 4 Be sure pump and fan are running ONLINE MAINTENANCE VIDEO AVAILABLE AT https bit ly 2HkhhDZ Depending on your particular indoor air quality we recommend cleaning your BioOx Clean Air System every 2 6 months In heavily contaminated areas clean every month Accumulation of sludge and particles in the reservoir can cause damage to the pump and lower the unit s cl...

Страница 13: ...er Wipe with cloth if needed 8 Run water through the water line clearing any buildup 4 Lift out air water inlet tray by gently squeezing openings Wipe or wash with damp cloth 5 Disconnect the pump line from the tee connection fitting You may have to twist side to side as you re pulling the fitting apart 9 Remove tee connection and run under water to clean ...

Страница 14: ...in this manner When ready to use refill with water add BioOx Natural Media and startup BioOx Reactor 85 of 14 15 10 Loosen debris accumulation in water box with brush It is best to remove debris into drain or garbage so that it does not re clog the openings on the water box 11 Rinse reservoir with water and drain debris If water flow slows or ceases OR if water consumption decreases to almost noth...

Страница 15: ...RMATION BioOx Reactor 85 of 15 15 Questions or comments regarding the BioOx Clean Air System should be directed to Air Water Solutions Inc P O Box 627 Nutley New Jersey 07110 301 246 0151 info bioox us www bioox us ...

Отзывы: