2-6 Pairing VEMO 

  The VEMO sensor can connect the mobile/tablet devices with bluetooth pairing connection.   

VEMO app can scan only the VEMO sensor with pairing connection interface. 

 

 
 
 
1. Press "+Add Monitor" Button 

 
 

 

 
 

2. Press         

 
 
 
 

 
 
 

3. Press "Scan" Button 

 
 
 

 
 
 

4. Heart icon will appear 

 
 
 

 
 

Содержание VEMO

Страница 1: ...Copyright 2020 By Bionet CO LTD All rights reserved VEMO User Manual Warning This device is designed only for veterinary use and please refer to this manual before use Max Ty Roy Ivy...

Страница 2: ...manual in English or any other language except a brief review or brief excerption for scientific paper Please carefully read this user manual before using Bionet device This monitoring system is desi...

Страница 3: ...nformation 13 2 2 VEMO Application Authentication 14 2 3 Main Display Description 15 2 4 VEMO Application Monitoring Display Description 16 2 5 VEMO Wireless Wearable Sensor 16 2 6 Pairing VEMO 17 2 7...

Страница 4: ...Precautions 45 3 VEMO Link 47 3 1 General Information 47 3 2 Starting VEMO Link 48 3 3 Monitoring VEMO Link 49 3 4 VEMO Link Display Description 50 3 5 VEMO Link Setting Up the Alarm 52 3 6 VEMO Link...

Страница 5: ...cedure as well as testing protocol by Bionet The warranty of this product is 1 year for main ECG sensor Manufacturer defects under warranty will be replaced by Bionet Please contact Bionet in case of...

Страница 6: ...etUS com Service Phone 877 924 6638 Fax 714 734 1761 Email support BionetUS com Please provide model name serial number date of purchase source of purchase Sales Acc Phone 877 924 6638 E mail sales Bi...

Страница 7: ...is to prevent of critical injury death or physical damage for the patient or users when this warning is neglected by users CAUTION CAUTION is to prevent any injuries or damage shy of death for the pa...

Страница 8: ...ature 50 F 113 F Humidity 10 95 Do not place near the heat or heating device Do not place with extremely high humidity or where the area has ventilation issue Storage Logistic Condition Condition of U...

Страница 9: ...Please stop using the device immediately and replace the unit NOTE In case of using the device near electrical generator X ray radio frequency device or electric wired cable unstable connection or er...

Страница 10: ...app to operate configure and monitor NOTE VEMO hardware screenshot and system component are used for example and actual material and display can be different in minor detail Functional Description VEM...

Страница 11: ...n mobile device VEMO can monitor 4 animal patients recommended and up to 6 animal patients In addition VEMO Link and VEMO Board can monitor several centralized mobile data under same local network 1 1...

Страница 12: ...cluded 1 Paring VEMO Mobile Device or Tablet 3 Monitor the Vital Signs 2 Place Adhesive to the chest of animal Patient 1 2 Product Component Using the System 1 VEMO Wireless Wearable Sensor 1 EA 2 Hyd...

Страница 13: ...6th Generation or better Screen 8 4 or more 9 7 or more Processor Octa Core 1 8 Quad Core 2 34 RAM 3 GB 2 GB Internal Storage 32 GB 32 GB Expandable Storage MicroSD 256GB 128GB OS Android 9 iOS 11 3...

Страница 14: ...tivity between VEMO sensor and tablet mobile devices With its alarm notification mode VEMO has audible visible alarm system to notify the alarm event to caregivers when vital signs are out of configur...

Страница 15: ...modes of program Please type the hospital name first and place the VEMO sensor to finalize the authentication 1 At the authentication window type in the clinic s name 2 Place the VEMO sensor on the sc...

Страница 16: ...logo 1 Previously recorded pet patient data can be reviewed at vital chart menu 2 The number of monitoring pet patients can be configured by 1 2 2 2 2 3 with display layout menu 3 User can setup other...

Страница 17: ...Sensor The VEMO sensor can monitor Heart Rate Respiration Rate and Electrocardiography The maximum VEMO sensor monitoring is up to 6 animal patients With its alarm notification mode VEMO has audible v...

Страница 18: ...EMO The VEMO sensor can connect the mobile tablet devices with bluetooth pairing connection VEMO app can scan only the VEMO sensor with pairing connection interface 1 Press Add Monitor Button 2 Press...

Страница 19: ...eck if the sensor serial number is registered successfully Ex C740135 7 Select the type of animal and Start Monitor button CAUTION 1 Check the VEMO sensor serial number at Monitor Settings window 2 DO...

Страница 20: ...orking well try manually scanning and pairing to initiate VEMO app 1 Check the serial number at the back of the VEMO sensor Ex C740135 2 Press the arrow key to see the list of serial numbers 3 Find th...

Страница 21: ...oints Avoid wrinkled area and wipe out the alcohol with dried cotton towel 2 Take out the VEMO sensor from the charging cradle 3 Peel out adhesive No 1 side 4 Attach the VEMO sensor on the No 1 side 5...

Страница 22: ...he VEMO sensor and any other adhesive usage will void your warranty When adhesive is being used with sensitive skin for small animals please remove the edge of the adhesive to minimize the adhesive co...

Страница 23: ...ion at dressing process Skin trouble at the contact point with VEMO sensor Make sure that adhesive contains hydrogel in good condition If hydrogel adhesive is out of validity DO NOT USE dried adhesive...

Страница 24: ...nsors Shave the animal patient and sterilize the VEMO with 70 alcohol The sensor should be applied on the middle of the chest Attach the sensor as PIC 1 Place the ECG sensor with its heart icon rotate...

Страница 25: ...20 12 30 24 59 BN OP VM 1 Peel out adhesive No 1 2 Attach the VEMO Sensor on the No 1 side 3 Peel out adhesive No 2 4 Place the VEMO sensor on the heart with its heart icon 90 degrees vertical and clo...

Страница 26: ...ator 1 Check the serial number at the back of the VEMO sensor Pairing status icon ECG Lead icon LEAD sensor connected LEAD sensor not connected When the LEAD sensor is not properly attached Check how...

Страница 27: ...V2 0 2020 12 30 26 59 BN OP VM Processing pairing and registration of the animal patient s information Information registered and pairing completed...

Страница 28: ...imately 32 seconds for measuring respiration rate Monitoring after sensor attached and pairing completed CAUTION VEMO s wireless wearable sensor s BPM measurement range is between 40 to 300 For patien...

Страница 29: ...app provides monitoring animal patients up to 6 sensors 4 sensors recommended Additionally the app can expand or divide the monitors up to 6 displays in one tablet This is a screen monitoring with 6...

Страница 30: ...V2 0 2020 12 30 29 59 BN OP VM 2 1 2 Sections 2 2 4 Sections 2 3 6 Sections 2 Sections 4 Sections 6 Sections 2 Sections Orderly Rotates 2 1 2 Sections 2 2 4 Sections 2 3 6 Sections...

Страница 31: ...een When the monitor is split into 2 sections or 4 sections scroll down to view the other monitors Expanding the Screen From the divided screen extend the screen to view one monitor Tap the monitor to...

Страница 32: ...or each animal patient When the measurement is above or below the limits or when the battery is low the alarm will go off Alarm On Off and Setting the Normal Range In the monitoring display of the ani...

Страница 33: ...Alarm On Off Setting the range of Heart Rate Setting the range of Respiratory Rate After setting the range tap the OK button below to save the settings With the Default button next to the OK button se...

Страница 34: ...V2 0 2020 12 30 33 59 BN OP VM When the rate is above or below the range the bell alarm icon will appear on top of the screen 1 Description of the alarm 2 Alarm snooze 3 Delete Alarm...

Страница 35: ...arm HR RR battery For all parameters there will be a bell icon and for each of the parameters there will be an animated icon to inform the alarm To indicate the cause of the alarm the icon and value w...

Страница 36: ...Click the 3 dots button on the top right screen and select Alarm Setting 2 Turn on off the monitor s alarm 3 Adjust the HR and RR 4 If the measurement is out of range the alarm will occur 5 Tap Defaul...

Страница 37: ...he following are the type of alarms Alarm Sound Setting the sound of the alarm including mute Vibrate Activates the Vibration Mode when an alarm occurs Snooze Minutes Setting the time for SNOOZE Alarm...

Страница 38: ...des the current HR RR measurement values of the animal patient to be automatically saved in a graph and chart format In the extended screen tap the chart icon on the top right side to view the chart T...

Страница 39: ...SP value to the chart Viewing the Line Chart Click on the Line Chart tab to change the Table chart values to a line graph and show the trend The type of chart Current Table Chart The current value wil...

Страница 40: ...ing the Chart PDF file Tap the Share button on the bottom to share through email or Cloud storage and save on the device The file will be saved in PDF format Table chart can only be shared in PDF form...

Страница 41: ...the attached VEMO sensor and the monitoring display review the past chart of an animal patient which is saved in the tablet s storage The previous charts that were saved can also be shared in PDF for...

Страница 42: ...V2 0 2020 12 30 41 59 BN OP VM 1 Review the chart by searching the previous animal patient 2 Review the chart by selecting from the list below...

Страница 43: ...arged by plugging into a powered USB port or a USB charger Smartphone Charger PC 1 After checking the charging terminal of the wireless wearable sensor and the charging terminal of the charging cradle...

Страница 44: ...r the cage 2 When attaching the VEMO wireless wearable patch please use the VEMO adhesive patch When using VEMO wireless wearable sensor a VEMO specific hydrogel adhesive patch must be used 3 Do not e...

Страница 45: ...al number Be sure to check the serial number when pairing the wireless wearable sensor 5 When using a wireless wearable sensor check the status of the VEMO sensor After connecting the wireless wearabl...

Страница 46: ...ets cut off deleting the Bluetooth data will solve the problem The VEMO app provides a guide on how to delete bluetooth data to the user helping the user to resolve a Bluetooth error 1 Select the menu...

Страница 47: ...VM 3 After the guide animation is finished click on the Data Delete Start button on the bottom 4 On the guide click Storage Delete Data button and the Bluetooth data will be deleted After deleting VEM...

Страница 48: ...device VEMO Link receives data from VEMO via Wi Fi and supports real time monitoring as it is on the VEMO monitoring screen to the user Wi Fi must use the clinic s internal network It has an integrate...

Страница 49: ...e Wi Fi of the tablet PC running the VEMO app first and then connect the Wi Fi of the mobile device running VEMO Link to same Wi Fi Connect the device of the VEMO app and the device of the VEMO Link a...

Страница 50: ...o the same Wi Fi as VEMO the list of animal patients being monitored is automatically registered to VEMO When a new animal patient is added or existing animal patient is deleted the addition deletion...

Страница 51: ...O Link Display Description Connection Icon Description Animal Patient Name Animal Patient Type Connection Status ECG Signal Unfold Respiration Readings Heart Rate Readings Cheese Normal Connection Use...

Страница 52: ...V2 0 2020 12 30 51 59 BN OP VM REFERENCE When changes are not reflected or reconnection is required due to network changes please scroll down the list to refresh...

Страница 53: ...ing Up the Alarm The alarm in VEMO Link is designed to generate the same alarm when an alarm occurs in the VEMO app If you turn off the screen of the mobile device after running VEMO Link it generates...

Страница 54: ...notification alarm is shown Contents of the alarm can be checked by touching the alarm icon in the upper left corner Alarm contents are displayed in descending order from the most recent alarm REFERE...

Страница 55: ...n off the notification The alarm can be turned on off by touching the bell icon on the top center of the VEMO Link REFERENCE If VEMO Link alarm is turned off VEMO alarm will not be received on the mob...

Страница 56: ...its accessories to wireless communications capabilities may be disturbed by other devices operating at the same frequency 9 Excessive body tissue hair or dry skin can affect signal quality 10 Do not b...

Страница 57: ...gments The device does not analyze ECG traces or detect the presence of arrhythmia This device monitors ECG waveforms 23 If there is interference from other nearby equipment follow the troubleshooting...

Страница 58: ...EMO app and run it again 2 Turn off and on the tablet PC s bluetooth 3 Check the serial number to see if other devices are paired Alarm Alarm does not go off 1 Check if the alarm sound is set to silen...

Страница 59: ...ification Sample Rate Accuracy ECG 128 ADC Resolution 16 bits Heart Rate 40 300 BPM Accelerometer 3 axis 5 ADC Resolution 14 bits 4g Respiratory 5 25 BrPM 4 BrPM Packet Transmission Every 1 second Net...

Страница 60: ...EMO Thank you for purchasing VEMO This product has passed through quality management and strict inspection Compensation criteria for the repair replacement or refund of this product follow consumer da...

Отзывы: