background image

Rinse and dry the pre-filter thoroughly before replacing

it in the inlet of the grill.

3. With the inlet grill (A) removed, remove the HEPA-type

cartridge (C) and dispose in the dustbin. DO NOT try

to wash and re-use the HEPA-type filter. Replace with

a new HEPA-type filter-BAPF30 removing the

protective plastic bag before inserting into the air

purifier.

4. Install the filter clip to the HEPA-type filters. The filter

clip can only be attached in one direction (see fig. 2).

The filter clip should easily slide onto the filter hang

tabs. Do not use force while attaching the filter clip to

the filter. Align the clip on the side of your HEPA-type

filter with the rails on the inside of the unit.

NOTE:

The pleated material and rubber gasket

should be facing towards the unit when applied.

5. Align the clips on the side of your HEPA-type filter

with the rails on the inside of the unit. Gently slide the

filter onto the rails (see fig. 3).

6. Replace the inlet grill by sliding back on to the unit.

Make sure that it snaps securely into position (the grill

only goes on one way)

NOTE:

Do not point outlet towards wall.

7. The filter life indicator light (E) should be reset once

the HEPA-type filters have been replaced. Reset the

indicator by pressing the Power button (

) on the

control panel for 2 seconds.

NOTE:

Before reading these instructions, please view the

corresponding illustrations.

DESCRIPTIONS (SEE FIG 1/4/5)

A. Inlet Grill
B. Washable Foam Pre-Filter
C. 99% HEPA/Carbon Filter
D. Filtered Air Outlet
E. Filter Indicator Light
F. Ionizer Light
G. Ionizer Control
H. Power Button
I. Speed Control
J. Power Indicator Light
K. Infrared
L. Operation Indicator Light

HOW THE AIR PURIFIER WORKS

Dirty, dust laden air is drawn through the rear of the air

purifier and through the multi-stage filtration system.
1. The carbon filter will help clear odors making the air

cleaner and fresher.

2. The HEPA-type filter entraps 99% of all smaller visible

and non-visible particles down to 2 microns in size.

PRODUCT FEATURES

Filter Life Indicator

Your air purifier has an indicator light (E) that illuminates

when its time to change the filters.

Ionizer

Your Bionaire™ Air Purifier has an independently

controlled ionizer, which when turned on, releases

AIR PURIFIER SAFETY

PLEASE READ AND SAVE
THESE IMPORTANT
SAFEGUARDS

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic safety precautions

should always be taken including the following:
1. Read all instructions before using appliance.
2. To avoid fire and shock hazard, plug the appliance

directly into an electrical outlet with the same voltage

as that indicated on the rating plate on your product.

3. If the filter is covered by a bag when shipped, remove

plastic bag before use.

4. Keep the cord out of heavy traffic areas. To avoid fire

hazard NEVER put the cord under rugs, near heat

registers, radiators, stoves or heaters.

5. To protect against electrical hazards DO NOT

immerse in water or other liquids. Do not use near

water.

6. Close supervision is necessary when any appliance is

used by, or near children or disabled persons.

7. Always unplug the air purifier before moving it, opening

the grill, changing the filters or whenever the air purifier is

not in use. Be sure to pull by the plug and not the cord.

8. NEVER drop or insert any object into any openings.
9. Do not operate any appliance with a damaged cord or

plug, if motor fan fails to rotate, after the appliance

malfunctions, or if it has been dropped or damaged in

any manner. Return appliance to manufacturer for

examination, electrical or mechanical adjustment or repair.

10.Use appliance only for the intended household use as

described in this manual. Any other use not recommended

by the manufacturer may cause fire, electric shock or injury

to persons. The use of attachments not recommended or

sold by the manuafacturer may cause hazards.

11.Do not use outdoors.
12.Never block the air openings, or place on soft surface,

such as bed or sofa, as this could cause the unit to

tip over thus blocking the air intake opening.

13.Keep unit from heated surfaces and open flames.
14.DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

the warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed

by qualified personnel only.

15.WARNING: To reduce the risk of fire or electrical

shock, DO NOT use this air purifier with any solid-

state speed control device.

16.DO NOT place anything on top of the unit.

PLEASE SAVE THESE
INSTRUCTIONS

PLEASE READ AND SAVE THESE IMPORTANT
INSTRUCTIONS.

With proper care and use, this Bionaire™ air purifier will

give you fresh, clean air for many years.

negative ions into the outgoing filtered air. Ions are tiny

particles that carry either a positive or negative charge.

These ions exist naturally all around us in the air, water

and ground. Both positive and negative ions are

colorless, odorless and completely harmless. Negative

ions help the air purification process by attaching

themselves to very small airborne particles in the room.
These particles take on a negative charge and may join

with positively charged particles, such as dust, pollen,

smoke and pet dander to form larger particles that are

then more readily captured by the filter system, or they

may be attracted to positively charged surfaces like walls

or floors.
You may also note, after extended use, that dust may

have collected around the grills or front panel.
This is from the ionization effect caused by the negative

ions exiting from the air outlet.This dust does not come

from the air output, but is drawn out of the uncleaned air

going past the air outlet.
This is additional evidence of the air cleaning

effectiveness of negative ions. The dust can be easily

removed with a clean, dampened cloth or soft brush.

NOTE:

it is important to change the HEPA-type filter at

recommended intervals. Using the ionizer in conjunction

with dirty filters may result in dirty particles exiting the air

purifier and being attracted to walls, carpets, furniture

and other household objects. These dirty particles may

prove very difficult to remove.

PRE-OPERATING INSTRUCTIONS

1. After removing the unit from the box, remove the

plastic covering from the unit.

2. Select a firm level place where there are no

obstructions to the air inlet (rear grill) (A) or filtered air

outlet (D).

3. Remove the inlet grill by pulling the grill (A) towards

you.

4. Remove both HEPA-type filters (C) by gripping on

both sides and pulling forward.

5. Remove protective plastic bag from each filter

cartridge. Install the filter clip to the HEPA-type filters.

The filter clip can only be attached to the hang tabs

on the filter one way (see fig 2). The filter clip should

easily slide onto the filter hang tabs. Do not use force

whilst attaching the filter clip to the filter. Align the clip

on the HEPA-type filter with the rails on the inside of

the unit (see fig. 3).

NOTE:

The pleated material and rubber gasket

should be facing towards the unit when applied.

6. Replace the inlet grill by sliding back on to the unit.

Make sure that it snaps securely into position (the grill

only goes on one way).

Air Purifier

BAP825RC

Read instructions before operating.

Retain for future reference

.

Instruction Leaflet

NOTE:

Do not point outlet towards wall.

OPERATING INSTRUCTIONS FOR THE CONTROL
PANEL AND REMOTE CONTROL

1. Plug into electrical outlet with the same voltage as

that indicated on the rating plate on your product.

2. Press the Power button (

). The unit will turn onto

high and the power light (J) will illuminate letting you

know the power is on.

3. You can then select the desired speed setting. This air

purifier has three speed settings. You can select from

HIGH (

), MEDIUM (

), or LOW (

) by

pushing the desired operating speed button on the

control panel or the remote control.

4. To release negative ions into the filtered air, press the

ionizer button (

) to ON and the light will illuminate.

5. For optimum air filtration, it is recommended to

operate the air purifier continuously. Its rugged motor

has been designed to give many years of use.

For continuous use, it’s recommended to operate the air

purifier at the MEDIUM setting. For quieter operation or

use in a bedroom, select the LOW setting. When high

levels of air pollution are present, select the HIGH setting

to quickly circulate and filter the room air.

REMOTE CONTROL

Your remote control requires (2) AAA batteries for

operation. To install the batteries, simply depress and

slide the back of the remote control with your thumb on

the arrow indentation. Insert batteries according to the

diagram shown inside and replace cover.
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard (carbon-zinc) or

rechargeable (nickel-cadmium) batteries.

CLEANING AND MAINTENANCE

1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned with a

soft, clean dampened cloth.

3. The filtered air outlet on the top of the unit can be

cleaned of dust with a small, soft brush.

4. If you wish to clean the inside of the air purifier, please

only use a dry, soft cloth to wipe it down.

FILTER REPLACEMENT

IMPORTANT: IN ORDER TO RETAIN THE EFFICIENCY

OF YOUR AIR PURIFIER, THE HEPA-TYPE FILTER

NEEDS TO BE CHANGED EVERY 6-9 MONTHS.
1. Every few weeks check the condition of the pre-filter (B).
2. Remove the inlet grill (A). If the foam pre-filter has

collected a noticeable amount of dust, remove it from

the inlet of the grill and wash it in warm soapy water.

REPLACEMENT FILTERS

BAPF30 HEPA-type Filter (usage 2 pcs)

How To Obtain Warranty Service: Please see the
country specific warranty insert or contact your local
authorized distributor for Bionaire™ appliances.

PLEASE DO NOT RETURN THIS PRODUCT TO THE

PLACE OF PURCHASE

© 2006 JCS/THG, LLC
Bionaire™ and the Bionaire logo™ are trademarks of

JCS/THG, LLC.

Printed in China

FFiigguurree 11

FFiigguurree 22

FFiigguurree 33

D

B

C

A

FFiigguurree 44

F

E

G

H

I

FFiigguurree 55 

J

I

H

G

L

K

Check to make sure the unit is

plugged in.
Check to make sure the unit is on

by turning the knob.
Make sure the filters are properly

installed and firmly close the door.

If the filters have not been

changed for 6 months or more,

change the HEPA-type filters.
Check to ensure nothing is

blocking the air inlet and filtered

air outlet.

Ensure all plastic bags have been

Unit will not

operate

Decreased air

flow

Noisy

Solution

TROUBLESHOOTING

Problem

Отзывы: