Rinse and dry the pre-filter thoroughly before replacing
it in the inlet of the grill.
3. With the inlet grill (A) removed, remove the HEPA-type
cartridge (C) and dispose in the dustbin. DO NOT try
to wash and re-use the HEPA-type filter. Replace with
a new HEPA-type filter-BAPF30 removing the
protective plastic bag before inserting into the air
purifier.
4. Install the filter clip to the HEPA-type filters. The filter
clip can only be attached in one direction (see fig. 2).
The filter clip should easily slide onto the filter hang
tabs. Do not use force while attaching the filter clip to
the filter. Align the clip on the side of your HEPA-type
filter with the rails on the inside of the unit.
NOTE:
The pleated material and rubber gasket
should be facing towards the unit when applied.
5. Align the clips on the side of your HEPA-type filter
with the rails on the inside of the unit. Gently slide the
filter onto the rails (see fig. 3).
6. Replace the inlet grill by sliding back on to the unit.
Make sure that it snaps securely into position (the grill
only goes on one way)
NOTE:
Do not point outlet towards wall.
7. The filter life indicator light (E) should be reset once
the HEPA-type filters have been replaced. Reset the
indicator by pressing the Power button (
) on the
control panel for 2 seconds.
NOTE:
Before reading these instructions, please view the
corresponding illustrations.
DESCRIPTIONS (SEE FIG 1/4/5)
A. Inlet Grill
B. Washable Foam Pre-Filter
C. 99% HEPA/Carbon Filter
D. Filtered Air Outlet
E. Filter Indicator Light
F. Ionizer Light
G. Ionizer Control
H. Power Button
I. Speed Control
J. Power Indicator Light
K. Infrared
L. Operation Indicator Light
HOW THE AIR PURIFIER WORKS
Dirty, dust laden air is drawn through the rear of the air
purifier and through the multi-stage filtration system.
1. The carbon filter will help clear odors making the air
cleaner and fresher.
2. The HEPA-type filter entraps 99% of all smaller visible
and non-visible particles down to 2 microns in size.
PRODUCT FEATURES
Filter Life Indicator
Your air purifier has an indicator light (E) that illuminates
when its time to change the filters.
Ionizer
Your Bionaire™ Air Purifier has an independently
controlled ionizer, which when turned on, releases
AIR PURIFIER SAFETY
PLEASE READ AND SAVE
THESE IMPORTANT
SAFEGUARDS
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety precautions
should always be taken including the following:
1. Read all instructions before using appliance.
2. To avoid fire and shock hazard, plug the appliance
directly into an electrical outlet with the same voltage
as that indicated on the rating plate on your product.
3. If the filter is covered by a bag when shipped, remove
plastic bag before use.
4. Keep the cord out of heavy traffic areas. To avoid fire
hazard NEVER put the cord under rugs, near heat
registers, radiators, stoves or heaters.
5. To protect against electrical hazards DO NOT
immerse in water or other liquids. Do not use near
water.
6. Close supervision is necessary when any appliance is
used by, or near children or disabled persons.
7. Always unplug the air purifier before moving it, opening
the grill, changing the filters or whenever the air purifier is
not in use. Be sure to pull by the plug and not the cord.
8. NEVER drop or insert any object into any openings.
9. Do not operate any appliance with a damaged cord or
plug, if motor fan fails to rotate, after the appliance
malfunctions, or if it has been dropped or damaged in
any manner. Return appliance to manufacturer for
examination, electrical or mechanical adjustment or repair.
10.Use appliance only for the intended household use as
described in this manual. Any other use not recommended
by the manufacturer may cause fire, electric shock or injury
to persons. The use of attachments not recommended or
sold by the manuafacturer may cause hazards.
11.Do not use outdoors.
12.Never block the air openings, or place on soft surface,
such as bed or sofa, as this could cause the unit to
tip over thus blocking the air intake opening.
13.Keep unit from heated surfaces and open flames.
14.DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
the warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed
by qualified personnel only.
15.WARNING: To reduce the risk of fire or electrical
shock, DO NOT use this air purifier with any solid-
state speed control device.
16.DO NOT place anything on top of the unit.
PLEASE SAVE THESE
INSTRUCTIONS
PLEASE READ AND SAVE THESE IMPORTANT
INSTRUCTIONS.
With proper care and use, this Bionaire™ air purifier will
give you fresh, clean air for many years.
negative ions into the outgoing filtered air. Ions are tiny
particles that carry either a positive or negative charge.
These ions exist naturally all around us in the air, water
and ground. Both positive and negative ions are
colorless, odorless and completely harmless. Negative
ions help the air purification process by attaching
themselves to very small airborne particles in the room.
These particles take on a negative charge and may join
with positively charged particles, such as dust, pollen,
smoke and pet dander to form larger particles that are
then more readily captured by the filter system, or they
may be attracted to positively charged surfaces like walls
or floors.
You may also note, after extended use, that dust may
have collected around the grills or front panel.
This is from the ionization effect caused by the negative
ions exiting from the air outlet.This dust does not come
from the air output, but is drawn out of the uncleaned air
going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be easily
removed with a clean, dampened cloth or soft brush.
NOTE:
it is important to change the HEPA-type filter at
recommended intervals. Using the ionizer in conjunction
with dirty filters may result in dirty particles exiting the air
purifier and being attracted to walls, carpets, furniture
and other household objects. These dirty particles may
prove very difficult to remove.
PRE-OPERATING INSTRUCTIONS
1. After removing the unit from the box, remove the
plastic covering from the unit.
2. Select a firm level place where there are no
obstructions to the air inlet (rear grill) (A) or filtered air
outlet (D).
3. Remove the inlet grill by pulling the grill (A) towards
you.
4. Remove both HEPA-type filters (C) by gripping on
both sides and pulling forward.
5. Remove protective plastic bag from each filter
cartridge. Install the filter clip to the HEPA-type filters.
The filter clip can only be attached to the hang tabs
on the filter one way (see fig 2). The filter clip should
easily slide onto the filter hang tabs. Do not use force
whilst attaching the filter clip to the filter. Align the clip
on the HEPA-type filter with the rails on the inside of
the unit (see fig. 3).
NOTE:
The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the unit.
Make sure that it snaps securely into position (the grill
only goes on one way).
Air Purifier
BAP825RC
Read instructions before operating.
Retain for future reference
.
Instruction Leaflet
NOTE:
Do not point outlet towards wall.
OPERATING INSTRUCTIONS FOR THE CONTROL
PANEL AND REMOTE CONTROL
1. Plug into electrical outlet with the same voltage as
that indicated on the rating plate on your product.
2. Press the Power button (
). The unit will turn onto
high and the power light (J) will illuminate letting you
know the power is on.
3. You can then select the desired speed setting. This air
purifier has three speed settings. You can select from
HIGH (
), MEDIUM (
), or LOW (
) by
pushing the desired operating speed button on the
control panel or the remote control.
4. To release negative ions into the filtered air, press the
ionizer button (
) to ON and the light will illuminate.
5. For optimum air filtration, it is recommended to
operate the air purifier continuously. Its rugged motor
has been designed to give many years of use.
For continuous use, it’s recommended to operate the air
purifier at the MEDIUM setting. For quieter operation or
use in a bedroom, select the LOW setting. When high
levels of air pollution are present, select the HIGH setting
to quickly circulate and filter the room air.
REMOTE CONTROL
Your remote control requires (2) AAA batteries for
operation. To install the batteries, simply depress and
slide the back of the remote control with your thumb on
the arrow indentation. Insert batteries according to the
diagram shown inside and replace cover.
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard (carbon-zinc) or
rechargeable (nickel-cadmium) batteries.
CLEANING AND MAINTENANCE
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned with a
soft, clean dampened cloth.
3. The filtered air outlet on the top of the unit can be
cleaned of dust with a small, soft brush.
4. If you wish to clean the inside of the air purifier, please
only use a dry, soft cloth to wipe it down.
FILTER REPLACEMENT
IMPORTANT: IN ORDER TO RETAIN THE EFFICIENCY
OF YOUR AIR PURIFIER, THE HEPA-TYPE FILTER
NEEDS TO BE CHANGED EVERY 6-9 MONTHS.
1. Every few weeks check the condition of the pre-filter (B).
2. Remove the inlet grill (A). If the foam pre-filter has
collected a noticeable amount of dust, remove it from
the inlet of the grill and wash it in warm soapy water.
REPLACEMENT FILTERS
BAPF30 HEPA-type Filter (usage 2 pcs)
How To Obtain Warranty Service: Please see the
country specific warranty insert or contact your local
authorized distributor for Bionaire™ appliances.
PLEASE DO NOT RETURN THIS PRODUCT TO THE
PLACE OF PURCHASE
© 2006 JCS/THG, LLC
Bionaire™ and the Bionaire logo™ are trademarks of
JCS/THG, LLC.
Printed in China
FFiigguurree 11
FFiigguurree 22
FFiigguurree 33
D
B
C
A
FFiigguurree 44
F
E
G
H
I
FFiigguurree 55
J
I
H
G
L
K
Check to make sure the unit is
plugged in.
Check to make sure the unit is on
by turning the knob.
Make sure the filters are properly
installed and firmly close the door.
If the filters have not been
changed for 6 months or more,
change the HEPA-type filters.
Check to ensure nothing is
blocking the air inlet and filtered
air outlet.
Ensure all plastic bags have been
Unit will not
operate
Decreased air
flow
Noisy
Solution
TROUBLESHOOTING
Problem