CORD SAFETY
• The length of cord used on this appliance was
selected to reduce tangling or tripping hazards.
• If a longer cord is necessary, an approved extension
cord may be used. The electrical rating of the extension
cord must be equal to or greater than the electrical
rating of the air purifier (see rating label marked on
product).
• Care must be taken to arrange the extension cord so
that it will not drape over the countertop or tabletop
where it can be pulled on by children or accidentally
tripped over.
GET TO KNOW YOUR AIR CLEANER
Your true HEPA air cleaner removes up to 99.97% of
airborne allergens as small as 0.3 microns, including
ragweed pollen, grass pollen, tree pollen, household dust,
dust mite debris, mold spores, pet dander, and smoke
from the air passing through the filter.
FEATURES
Dual Position
The air purifier can stand upright or lie on its side.
It is also designed to fit with its back flush against the wall.
When positioning the unit, please be sure the air inlet
grill, filters and air outlet are not blocked to ensure
maximum airflow.
Filter Window
On the front grill, there is a
small opening that will enable
you to see your carbon filter at a
glance. As it picks up dust and debris, the window will
turn to gray indicating the air purifier is working and you
may need to change the carbon filters.
HEPA Filter Indicator
When the HEPA filter is approaching the end of its useful life,
the indicator light will turn red. When the red indicator light
starts flashing, it is time to change the HEPA filter.
Carbon Filter Indicator
When the carbon filter indicator light turns yellow, it is
time to change the carbon filter.
Timer
The timer allows you to run your air purifier at your
convenience, for up to 16 hours. To operate using the
timer mode, at the control panel on the air purifier, turn
the unit on and select a speed.
To activate the timer, press the "
+
" and "
-
" speed buttons
at the same time for approximately 3 seconds.
The numbers in the display will begin flashing and the
light will appear to indicate timer function is on. Push “
+
”
or “
-
” button to cycle through the timer options (1-16).
When you have reached desired hours that you want
your air purifier to run, release finger from the button;
the numbers will stop flashing, timer will be on, and the
screen will revert back to displaying a speed setting. The
air purifier will then operate for the selected period of
time and shut off automatically. Speeds can be changed
once the timer is activated by pushing the “
+
” or “
-
“
buttons. To view the time left to run once timer has been
set, push the “
+
” and “
-
“ at the same time for 3 seconds.
You can manually turn the air purifier off by pressing the
( ) button once.
BEFORE USE
NOTE:
The front grill should not be removed when the
unit is on its side.
1. After removing the unit from the box, take the
plastic covering off the unit and properly dispose of
it.
2. Lay the air purifier flat on its back with the front /
air intake grill pointing up.
3. Open the door of the air purifier by carefully placing
fingers in indentation on the right side of the door
and gently pull forward.
4. The carbon filters, which are packed in a plastic bag
in the box, should be removed from plastic bag and
then placed on each of the HEPA filters. The plastic
tabs on the HEPA filter will hold the carbon in place
(see Figure 1).
5. Replace the front grill by aligning tab on left hand
side and swinging down. Gently press until front grill
is firmly in place.
OPERATING INSTRUCTIONS
1. Select location where air intake grill and filtered air
outlet are not obstructed.
2. Plug into a 120V AC electrical outlet.
3. The air purifier is now ready for use. Turn the unit on
by pressing the ( ) button (the air cleaner will turn
on to the highest setting). Select the desired
operating speed: High (4), Medium (3), Low (2) or
Sleep (1) by pushing the "
+
" or "
-
" buttons on the
control panel.
For continuous use, it is recommended to operate the air
purifier at the MEDIUM setting. For quieter operation or
use in a bedroom, select the LOW or Sleep setting. When
high levels of air pollution are present, select the HIGH
setting to quickly circulate and filter the room air.
CLEANING/MAINTENANCE
INSTRUCTIONS
1. Turn the air purifier off and unplug it before
cleaning.
2. The outside of the air purifier can be cleaned with a
soft, clean damp cloth.
3. The filtered air outlet / top air vent can be cleaned
of dust with a small, soft brush.
4. If you wish to clean the inside of the air purifier,
please remove filters and only use a dry, soft cloth to
wipe it down.
5. DO NOT wash filters.
WARNING:
Do not allow moisture to come in contact
with the main housing of the air purifier.
FILTER REPLACEMENT INSTRUCTIONS
1. On average, HEPA filters need to be replaced every
12-18 months. Carbon filters need to be replaced
every 3-6 months. Filter life will vary depending on
air quality and usage.
I M P O R TA N T S A F E G U A R D S
F E AT U R E S
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons. These precautions
include:
• Read all instructions before using the appliance.
• To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
• If the filter is covered by a bag when shipped:
Remove plastic bag before use.
• Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs, near
heat registers, radiators, stoves, or heaters.
• To protect against electrical hazards, DO NOT
immerse in water or other liquids. Do not use near
water.
• Close supervision is necessary when any appliance is
used by or near children, or disabled persons.
• Always unplug the air cleaner before moving or
cleaning the unit, opening the grill, changing the
filters and whenever the unit is not in use. To
disconnect the unit, be sure to pull the plug and not
the cord.
• NEVER drop or insert any objects into the openings of
the unit.
• Do not operate any appliance with a damaged cord
or plug. If the motor fan fails to operate or the unit
has been dropped or damaged in any manner, return
appliance to manufacturer for examination and/or
repair.
• Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold by the
manufacturer may cause hazards.
• DO NOT use outdoors.
• NEVER place on a soft surface such as a bed or sofa
as this could cause the unit to tip over and block the
air inlet or outlet grills.
• Keep unit away from heated surfaces and open
flames.
• DO NOT place anything on top of unit.
• DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so will void
your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed
by Jarden Consumer Solutions or an authorized
Jarden Consumer Solutions Service Center.
•
WARNING:
To reduce the risk of fire or electric
shock, DO NOT use this air cleaner with any solid-
state speed control device.
• Always turn the appliance off before unplugging it.
• NEVER use detergents, gasoline, glass cleaner,
furniture polish, paint thinner or other household
solvents to clean any part of the air cleaner.
• The ionizer in this appliance produces less ozone than
the UL established limits of 50ppb (parts per billion).
However, in high concentrations, ozone can be
harmful to birds and small pets. To prevent ozone
buildup, we suggest using the ionizer in well
ventilated areas with the fan on.
• This appliance should only be used in a room with
temperatures between 40° F and 110° F.
PLEASE SAVE THESE
IMPORTANT SAFETY
INSTRUCTIONS
O P E R AT I O N S ,
C L E A N I N G / M A I N T E N A N C E
Figure 2
A
B
C
D
F
E
A. SPEED CONTROL
B. FILTER LIFE INDICATOR
C. FILTER RESET
D. POWER BUTTON
E. FILTERED AIR EXHAUST GRILL
F. AIR INTAKE GRILL
R E P L A C E M E N T F I LT E R
Figure 1
A
B
A. HEPA FILTER
B. CARBON FILTER
A
C
B
D
2. Turn off and unplug the air purifier before
attempting to replace the filters.
3. To access filter compartment, open front grill door by
placing fingers in the indentation on the right side of
the door, gently pull to the right before pulling forward
(see Figure 3).
4. Remove each of the filters from the unit by pulling
gently towards you.
5. To replace the carbon filter, simply remove the old
carbon filter and insert a new carbon filter in its
place after first removing the plastic bag. Using the
plastic tabs as a guildline (see Figure 1).
6. To replace the HEPA filter, discard the old HEPA filters. DO
NOT attempt to clean. Put the carbon filter back on the
new HEPA filter. Insert the new HAPF600 HEPA filter into
the unit, by sliding it onto the hang tabs (see Figure 4).
7. After replacing the filters, RESET the Filter Life Indicator
by inserting a small object (such as a paper clip) into
the hole below the filter change light marked reset
(
). The red LED is the HEPA filter light and the
yellow LED is the carbon filter light.
REPLACEMENT FILTERS ARE AS FOLLOWS:
NOTE:
Carbon and HEPA Filters are not washable and
should be replaced at the recommended intervals.
NOTE:
Filters can be purchased at a retailer near you or
by calling 1-866-518-3157.
Figure 4
HANG TABS
Air Cleaner
Model
Number
Filter Quantity
Needed
Filter
Model
Number
Filter
Description
BAP756-U
3
True HEPA
Filter
HAPF600
HAP600D
B filter
BAP756-U
3
Carbon
filter
HAP60
C filter
Figure 3
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit in
a polarized outlet only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit, contact a qualified
electrician to install the proper outlet.
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS
SAFETY FEATURE IN ANY WAY.
-2-
-3-
-4-
-5-
BAP756-U_12EM1.qxd:163514 9/28/12 3:18 PM Page 2