Biomorph Pro SuperPlus Скачать руководство пользователя страница 15

1. 

Check for obstructions above, below and around the 

desk that may impede movement through the desk’s full 

adjustment range of 22” - 48.5”. If there is anything more 

than 18” high under either surface then it will cause an 

obstruction and error E29 when the surface is lowered to 

the lowest position to reset the system, and cause the 

system to freeze.

3. 

Hold the DOWN button to cycle the table to its lowest 

position. If the table does not move at first take your finger 

off the down button, then press and release the down 

button, and then immediately press and hold the down 

button until the desktop is at the lowest position, aprx. 22” 

off the floor.

2. 

Re-check the power outlet with another electrical 

device to ensure that you have power to the desk.

Check power cord connection to controller box, and check 

all other connections from the legs and switch(es) to the 

controller box.

5. 

With the desk lowered in the lowest position press and 

hold the down button for 5-10 seconds. The table will adjust 

up and down a fraction of an inch, and may show E codes if 

the switch has a display, which is normal, then show the 

height. This is the sign that the table has fully reset.

4. 

Once the desk has lowered to its lowest point allow the 

table to come to a complete stop and then take you finger 

off of the down button.

Troubleshooting Guide

For Biomorph Maxo, Flexo, Level, and Plus Series Desks

Check for obstructions above, below and around the desk 

that may impede movement through the desk’s full adjust-

ment range of 22” - 48.5”. If there is anything more than 18” 

high under either surface then it will cause an obstruction 

and error E29 when the surface is lowered to the lowest 

position to reset the system, and cause the system to 

freeze.

7. 

If the above does not work initially then unplug all 

electrical connections and re-plug all connections back in to 

ensure good connections with all electrical parts, and repeat 

the above process. At this point the table should adjust up 

and down freely. If you have a dual surface desk then this 

procedure must be done with both surfaces using the 

toggle button.

If the surface(es) will not move at all after the above proce-

dure note the E Code (if any) and call us at 888 302 3375 for 

fur-ther troubleshooting support.

6. 

If the desk does not level off after pressing and holding 

the down button, then press the down button again for 5-10 

sec-onds until the desk adjusts up the fraction of an inch 

and shows the height. This may need to be attempted up to 

three times in suc-cession before movement is seen 

depending on the reason why the table needs to be reset. 

The digital readout may cycle through several E codes - this 

is normal.

Содержание Pro SuperPlus

Страница 1: ...Pro SuperPlus Ground Support Equipment US ltd DBA Biomorph 11 Broadway New York NY 10004 Tel and Fax 888 302 3375 info biomorphdesk com www biomorph com ...

Страница 2: ...Extension 1 Phillips Bit 2 Phillips Bit Hex Bit Leg Qty 5 Bracket Qty 1 3 Port Control Box Qty 1 Wire Clips Qty Table Top Qty 1 Cable Cab Qty 2 45 Digital Readout Switch and 45 Switch Bracket Qty 2 Cable Chains Qty 2 RH Adjustable Crossbar Section Qty 4 LH Adjustable Crossbar Section Qty 4 Adjustable Crossbar Qty 4 a LH Top Plate Qty 2 b RH Top Plate Qty 2 c Bracket Qty 1 e i j k l o m 2 Port Cont...

Страница 3: ... this procedure is not followed then tops will not line up with frame DO NOT REMOVE PROTECTIVE MATERIAL FROMTOPS UNTIL FINAL ASSEMBLY IMPORTANT When moving this desk do not drag frame as it can cause leg actuators to bind and fail Always lift off floor using frame not tops e i i i j f h h h h g g g g d d a a a b b c c M6 x 12 Screw Qty 16 a a a a b b c c b c a 1 ...

Страница 4: ...rt upward Tighten screws using Allen Wrench Note These screws may be loosened to re adjust CPU Support to accomodate CPU Place Leg A being installed in Step 3 into Shroud e Proceed to Step 4 Installing Leg Mounted CPU Holder optional e f a M6 Flange Head Nut Qty 4 M6 x 8 Screw Qty 4 ...

Страница 5: ...sembly continued Leg Assembly continued a e 4a 4b 4c a a a f f f Glide Qty 4 M6 x 12 Screw Qty 8 Note Longer end of Foot must face toward front user side a a a a d d a d d a 2 3 Glide Qty 4 M6 x 12 Screw Qty 16 ...

Страница 6: ...5 Crossbar Assembly LH Side RH Side LH Side RH Side g g h h g Use these holes h Use these holes g Use these holes h Use these holes M6 x 12 Screw Qty 8 ...

Страница 7: ...6 M6 x 12 Screw Qty 8 M6 Flange Head Nut Qty 8 g Use these holes Use these holes i LH Side RH Side g Use these holes i LH Side h Use these holes i RH Side i i g g h h i i i h Crossbar Assembly continued ...

Страница 8: ...7 Crossbar Assembly continued M6 x 12 Screw Qty 8 M6 Flange Head Nut Qty 8 i i k k h h g g LH Side RH Side Use these holes i h Use these holes i g Use these holes i h Use these holes i g LH Side RH Side ...

Страница 9: ...8 Crossbar Assembly continued Crossbar Assembly continued 8 M6 x 12 Screw Qty 4 h g j M6 x 12 Screw Qty 4 j h g j h g ...

Страница 10: ...9 Top Assembly k k 5 x 25mm Wood Screw Qty 62 ...

Страница 11: ...ical Components 10 m n l l 45 Digital Readout Switch and 45 Switch Bracket Qty 2 16mm PH Wood Screw Qty 4 l 3 Port Control Box Qty 1 45mm PH Wood Screw Qty 2 m 2 Port Control Box Qty 1 45mm PH Wood Screw Qty 2 n ...

Страница 12: ...11 Cable Management Cable Cab Qty 2 p p p Cable Chains Qty 2 o o o 16mm PH Wood Screw Qty 8 16mm PH Wood Screw Qty 6 ...

Страница 13: ...ONG cables to connect both front legs to ports 1 2 in controller box GROMMET HOLE Place grommet into grommet hole Route cable accordingly CABLETRACKS Red FRONT surface Blue REAR surface 2 PORT CONTROLLER box for FRONT surface SWITCH for REAR surface use long 45 angle bracket Control switches connect to port A1 SWITCH for FRONT surface use long 45 angle bracket Control switches connect to port A1 W...

Страница 14: ...rate both surfaces independently The default setting shows the number 1 in the digital display which refers to the near surface By pushing the toggle button the display will show number 2 which will then operate the rear surface Press toggle again to return to number 1 Setting Initial Height It may be necessary to adjust the displayed height due to different thicknesses of desktops or addition of ...

Страница 15: ... to come to a complete stop and then take you finger off of the down button Troubleshooting Guide For Biomorph Maxo Flexo Level and Plus Series Desks Check for obstructions above below and around the desk that may impede movement through the desk s full adjust ment range of 22 48 5 If there is anything more than 18 high under either surface then it will cause an obstruction and error E29 when the ...

Отзывы: