background image

23 | 

P a g e

 

 

BIOMARK 601 READER TECHNICAL SPECIFICATIONS 

RFID Compatibility: 

ISO 11784 & 11785 HDX and FDX-B and Fecava 
FDX-A 

Form Factor: 

Portable Handheld Santoprene Enclosure 

User Interface: 

Single “On/Press to Read” Activation Button 

Menu & Scroll Up/Down Option Select Buttons 

16 character (2x8) LCD display 

Audible Beeper and Red LED “Read” Indicators 

ID Code Display 
Format 

Decimal or Hexadecimal 

Clock/Calendar 

ddmmyy and hh:mm:ss (12 or 24 hour format) 

Memory: 

1600 ID codes (including Mfr Code and 
date/time) 

Battery Power: 

4 AA Alkaline battery cells, or 

4 AA NiCad or NiMH rechargeable battery cells 

Electromagnetic 
Compatibility (EMC) 
Certifications 

  

FCC Part 15 Class A 

CISPR 22 (EN55022), and EN50082-1 

ETSI 300 330-1 

Industry Canada RSS-210 

PHYSICAL/ENVIRONMENTAL

 

Dimensions: 

275 mm L x 68 mm W x 83 mm H 

Weight: 

Approx 0.35 kg. with alkaline battery installed 

Enclosure Material: 

Monsanto Santoprene ® 

Color: 

Medium Gray (Pantone 423C) 

Operate 
Temperature 

+5ºC to +40ºC (IEC68.2.1/.2) 

Storage 
Temperature 

-10ºC to +55ºC  (IEC68.2.1/.2) 

Содержание 601

Страница 1: ...1 P a g e 601 HANDHELD READER USER MANUAL ...

Страница 2: ...2 P a g e ...

Страница 3: ...tant reader It has many options for configurations making it very versatile The reader provides outstanding performance when coupled with Biomark PIT tags that make it ideal for most mark recapture applications For technical support please call us 1 2082750011 Or email customerservice biomark com www biomark com ...

Страница 4: ... Charging 9 Getting started and reading tags 10 11 Powering the reader off 20 Configuring the reader 12 Display set up 13 Reader settings 14 Time date 16 Stored ID codes 17 RS232 settings 18 ID code format 18 Reader info 20 Downloading stored tag memory 21 Connecting to BioTerm software 22 Reader technical specification 23 Warranty information 25 Regulatory notices 26 ...

Страница 5: ...ically for use in fish and wildlife research applications The 601 is well suited to handheld field use 1 2 The Reader features Water resistant housing Shockproof per IEC 68 2 27 Memory for storage of 1 600 tag codes High performance ISO 11784 11785 HDX FDX B 134 2 kHz and 125 kHz detecting antenna Time Date stamp on each read Hand strap Rechargeable NiMH 4 AA battery capable or 4 AA or AC power ca...

Страница 6: ...ted optionally lights with Options Menu selections Scan Face Reader surface planar with scanning coil Transponder coil axis should be perpendicular to Reader scan face for maximum reading distance Handle Ambidextrous gripping surface End Cap User removable component for accessing battery compartment End Cap Screw Retains End cap in place Attachment Pin and Ring Used to attach wrist strap belt hook...

Страница 7: ...le free service If using batteries ensure that they are installed correctly The gasket around the endcap should be free of twists and sit flush in groove to best protect against moisture and dust Always tighten the endcap screw until the endcap is snug on the Reader Do not over tighten as this can create gaps in which moisture and dust can enter the Reader If the Reader has become wet allow time f...

Страница 8: ...a dry place 2 1 Battery Installation Unscrew the endcap screw by turning it counter clockwise Remove the endcap by pulling it away from the Readers handle Install alkaline or rechargeable batteries observing the polarity orientation icons located beneath the battery channel Replace endcap on the handle end ensuring the gasket is sitting flush on the endcap guiding the connector plugs into their re...

Страница 9: ...wer supply into an outlet The provided NiMH rechargeable batteries will take 12 to 16 hours to fully charge from a completely discharged state The trickle charger may be left connected to the Reader continuously when the Reader is being used with the AC Power Communication cable endcap Overcharging of the rechargeable batteries will not occur NOTE Do not use the AC power supply while alkaline batt...

Страница 10: ...ng to AC power the Biomark 601 Handheld reader is ready for operation To power on the Reader press the READ button for at least 1 second The Reader will indicate a successful power up by emitting a tone a momentary flashing of the Red LED indicator black boxes appearing briefly on the LCD screen and finally displaying READER READY on the LCD screen If you have the LAST TAG option enabled instead o...

Страница 11: ...hree major factors are listed below to help ensure the best results when attempting to detect tags Tag Orientation Maximum read distance is attained when a tag is perpendicular to the face of the antenna best orientation Minimum distance will be achieved when the tag is parallel to the face of the antenna worst orientation Electrical Noise Interference Detection range can be affected by electromag...

Страница 12: ...internal battery and will not be affected by the removal of the AA batteries or AC power 4 Configuring the Biomark 601 Handheld Reader The Biomark 601 Handheld reader has many useful options to help meet researcher s needs To begin configuring the Reader it is important to familiarize yourself with accessing and manipulating the Readers menu To access the menu press the MENU button located in the ...

Страница 13: ...in a tag ID For example 982 000000012345 will display if this option is enabled if disabled the same ID would display as 982 12345 If the tag ID starts with a non zero character such as 982 100000012345 either setting will result in the same display The default for this setting is YES LAST TAG Options are ON or OFF If enabled the Reader will display the last tag detected upon powering up If disabl...

Страница 14: ...ault for this setting is EVERY READ NOTE The FIRST READ function acts as a unique mode setting If a tag is scanned while enabled it cannot be scanned again until another unique tag is scanned first Once this second tag is scanned the original tag can be rescanned again AUTOREAD Options are ON or Off If enabled this setting will power up the Reader in read mode It will remain in read mode until a t...

Страница 15: ...0 min NOTE If TIMEROFF is selected the user must manually power the Reader down READTIME Options are from 1 to 9 seconds This setting allows the user to set the amount of time the Reader will search for a tag once the READ button is pressed The READ button can be held down for a continuous read If a tag is detected before the read time expires or when being held continuously the reader will revert...

Страница 16: ...OTE Some tagging programs require a specific date separator in order to successfully download the time stamp DATE This setting displays the current date and date separator that has been selected The date can be changed in this screen by using the READ button to cycle through the displayed values and the SCROLL UP and SCROLL DOWN buttons to adjust those values TIME FMT Options are 12 HOUR or 24 HOU...

Страница 17: ...or SCROLL DOWN button will bring up the message DELETE YES NO Pushing the READ button will move the star between the YES and NO Pressing the SCROLL UP or SCROLL DOWN button while the YES is selected will erase all stored tag information NOTE The Delete Tag option will not be available if there are no tags stored in the memory Scroll through current tags stored in the memory and downloading individ...

Страница 18: ...ow the information will be presented when downloaded to a computer FORMAT Options are HEX Hexadecimal or DEC Decimal Determines what tag format is displayed once a successful detection occurs Hexadecimal format includes letters A through F as well as numbers 0 through 9 Decimal format uses only numbers Any 125 kHz FDX A tags detected will only be displayed in their 10 digit Hexadecimal code even i...

Страница 19: ...etting is YES TIMEDATE Options are ON or OFF This setting will determine if the time and date stamp associated with every tag detection is transmitted when the memory is downloaded If enabled downloaded tags will have a time and date stamp associated with them If disabled downloaded tags will not have a time and date stamp associated with them The default for this setting is ON NOTE If the TIMEDAT...

Страница 20: ...delimiter format to be a specific character 1st CHAR Options are NONE L X G This setting will add the selected character to the beginning of a tag ID field when downloaded The default for this setting is NONE TAG TYPE Options are NONE ALLFLEX TI RFID This setting sets character fields The default for this setting is NONE 4 7 Reader Info This submenu displays the Readers current software and hardwa...

Страница 21: ... following 9600 baud rate 8 data bits no parity and flow control none Note It is important to note that the latest PC s rarely come equipped with a 9 pin serial ports If your computer does not have a 9 pin serial port a USB to serial adapter has been included with the Reader It is important to install the drivers for this adapter before use If you are using the Biomark Tag Manager program to acces...

Страница 22: ...xt to Serial Port Most computers have only one COM Port which usually defaults to COM1 NOTE If you do not see the correct port listed choose the REFRESH button to the right of the menu If the correct port still does not appear there is a problem with your connection Once you have the COM Port selected select the 9600 in the drop down to the right Select whether or not you want to use the Text Capt...

Страница 23: ...ar ddmmyy and hh mm ss 12 or 24 hour format Memory 1600 ID codes including Mfr Code and date time Battery Power 4 AA Alkaline battery cells or 4 AA NiCad or NiMH rechargeable battery cells Electromagnetic Compatibility EMC Certifications FCC Part 15 Class A CISPR 22 EN55022 and EN50082 1 ETSI 300 330 1 Industry Canada RSS 210 PHYSICAL ENVIRONMENTAL Dimensions 275 mm L x 68 mm W x 83 mm H Weight Ap...

Страница 24: ...s biological and organic fluids aqueous solutions and mild acid alkaline solutions RELIABILITY MTBF 50 000 hours MTTR 0 5 hours Expected Life 5 years minimum PERFORMANCE Read Distances HPT8 3 5 5 inches HPT9 3 5 inches HPT12 5 7 inches HPT22 7 11 inches FDX A 5 8 5 inches Reading Orientation 0º to 30º with less than 10 range decrease Read Error Rate Less than 1 in 106 Read Cycles Battery 5 000 Alk...

Страница 25: ...ing from misuse accident modification unsuitable physical or operating environment improper maintenance or failure caused by a product for which Biomark Inc is not responsible The warranty is voided by removal or alteration of Parts or Equipment identification labels Warranty Service Warranty service may be obtained from Biomark Inc headquartered in Boise Idaho by receiving a Return Material Autho...

Страница 26: ...ween the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQU...

Страница 27: ...27 P a g e NOTES ...

Отзывы: