FAST DIGITAL THERMOMETER

Model T 103

DESCRIPTION OF THIS PRODUCT

Display field

Measuring sensor

ON/OFF button

We congratulate you on your purchase of this thermometer. To correctly utilize all 
the advantages of this product, you should familiarize yourself with these operating 
instructions before using the thermometer the first time. Then keep these 
instructions in a safe place for future reference.

SPECIAL FEATURES

Maximum thermometer:

Acoustic signal: 

Automatic self-test:

Temperature measuremen

t: up to 10 seconds fast measurement of the body

Digital display:
Memory: 
Automatic switchoff: 
100% waterproof:
Flexible tip: 

 Battery:

 

 In each case the highest measured temperature is 

     displayed until the appliance switches off.

 

indicates appliance ready for use and 

    measurement completed .

 

 guarantees a specified measuring accuracy for each 

     temperature reading! ERR

error is immediately indicated if any deviation 

     is registered.

 

     temperature reading.

 

 for temperature changes as minor as 0.1 .

 

automatic storage of last measured temperature.

 

after approx.10 minutes-for longer battery life.

 

 can be completely immersed for cleaning.

 

can be bent up to 45 .

 1.5/1.55V

》 ﹙




°

IMPORTANT SAFETY INSTRUCTIONS


°

 The thermometer is suitable exclusively for measurement of the body 

     temperature!

 The minimum measurement time until the signaling tone [beep] must be 

     maintained without exception!

 The thermometer contains small parts (battery, etc.) that can be swallowed by 

     children. Therefore never leave the thermometer unattended to children.

 Protect the thermometer from hitting and striking!
 Avoid bending the tip more than 45 !
 Avoid ambient temperatures above 60 .NEVER boil the thermometer

FUNCTION TEST

ERR

BATTERY REPLACEMENT

To turn on the thermometer, push the button over the display window; a short 

signaling tone [beep] signals

thermometer ON. A display test is performed by

 

 an  Lo and a flashing 

appear at the upper right of the display. The thermometer is now ready for use.

Proper functioning of the thermometer is tested automatically each time it is turned 
on. If a malfunction is detected(measurement inaccuracy), this is indicated by 

on the display, and a measurement becomes impossible. In this case, the 

thermometer must be replaced. 

When the 

symbol appears in the lower right of the display, the battery is 

exhausted and needs replacing. For the battery replacement please remove the 
compartment lid of the thermometer. Replace the exhausted battery by positioning 
the + at the top. Make sure a battery of the same type is on hand. Batteries can be 
purchased at any electrical goods shops. For battery disposal please refer to 

safety instructions .

《 

《 ℃ 》

《     》

USING THE THERMOMETER

STORAGE OF MEASURED VALUES

During a measurement, the current temperature is displayed continuously. The

symbol flashes during this period of time. If the signaling tone sounds(beep-

beep-beep-beep 10 times) and the 

is no longer flashing, this means that the 

thermometer is ready for reading. To prolong the life of the battery, turn it off after 
use by pressing the operating button briefly, otherwise the thermometer will 
automatically turn off after about 10 minutes. 

《 ℃ 》

《 ℃ 》

This device stores the last reading automatically. When you turn on the device, it 
displays the last reading automatically right after the display check.

MEASURING METHODS
In the mouth (oral)

In the anus (rectal)

In the armpit (axillary)

Position the thermometer in one of the two pockets under the tongue, to the left or 
right of the root of the tongue, The measuring sensor must be in good contact with 
the tissue. Close your mouth and breath evenly through the nose to prevent the 
measurement from being influenced by inhaled/exhaled air.
Approx. measuring time: 20 seconds.

This is the most reliable measuring method, and is especially appropriate for 
infants and small children. Carefully insert the tip of the thermometer 2 to 3 cm 
into the anal aperture.
Approx. measuring time: 10 seconds.

.

From a medical viewpoint, this method will always provide inaccurate readings, 
and should not be used if precise measurements are required.
Approx. measuring time: 30 seconds.

• 

Use only the commercial disinfectants listed in the section cleaning 

and 

    disinfecting to clean the thermometer. The thermometer must be intact when 

    immersed in liquid disinfectant.

Warning

The thermometer contains a long-life battery. For disposal, please 

comply with local regulations for special waste.

The manufacturer recommends to verify the accuracy by an authorized 
laboratory every 2 years.

tuning on all symbols for about 1 second, then display last measurement memory

(only valid to an successful last measurement), 

measured temperture already reached to a stable level, completed measurement,

TURNING ON THE THERMOMETER