50 

 

P

RODUCT 

S

PECIFICATION

 

CPU   

32bit Micro processor,    400MHz   

Memory   

NAND Flash 128Mbyte, 64Mbyte RAM   

Backup Memory(optional) 

Mini SD Memory 1Gbyte   

LCD   

2.8” color LCD   

Sensor   

Optic, 500 DPI   

NTSC Camera(optional)   

Built-in 

Focal length : 3.7mm   

Iris : fixed   

Angle Of view : 92˚(D)   

Proximity Sensor(optional) 

Camera automatically turns on in proximity 

Size   

(W)149mm X (L)132mm X (D)52mm   

Fingerprint data size   

512 byte   

Registered Personnel   

1:N user: 3,000 persons   

RF card : 10,000 persons   

Log data : 100,000 data   

IN/OUT port   

Input : Door sensor, Lock sensor   

Output : Lock relay, Exit button   

*When linked up to I/O MAN 

Lock 2 port , Exit button, Fire alarm, Door sensor,   

Lock sensor, Output 2 port, Spare I/O 5 port   

Communication 

TCP/IP     

Language/Voice   

Korea/ English (Support multi languages)   

User can change voice file (Wave File only)   

Key phone(option)   

Capable  of  extension  call  linked  up  with  internal 

switchboard(Key phone) 

Power consumption   

400mA   

Built-in RF 

Mifare(13.56MHz, ISO14443A) 

Built-in option   

Camera, Keyphone Call 

Other option   

I/O MAN   

 

 

Содержание Cadenacio

Страница 1: ...Cadenacio Reference Manual Cadenacio FP MF BKS 5000 FP MF Catenaccio Lite Cadenacio Lite BKS 5100 Ver 2 0...

Страница 2: ...tion 20 Card Registration 21 Password Registration 22 When setting with Fingerprint or Card 22 3 Edit User 23 4 Delete User 24 3 Mode Setup Access Control Time Attendance Setup Meals Setup 24 1 Access...

Страница 3: ...39 1 SD Memory Function 40 2 Auto Log Data Backup Function 40 3 Import from SD memory 40 4 Export to SD Memory 41 5 How to Update Firmware 42 9 Initialization 42 10 Q A 43 1 I cannot view the LCD from...

Страница 4: ...reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving ante...

Страница 5: ...lease take care when a customer personally installs or relocates the product Do not install in places where there is a lot of direct sunlight or moisture dust or soot There is the cause of electric le...

Страница 6: ...et to 1111 when CADENACI is shipped out from the plant 1 2 Please connect the cable when the power is not authorized When fingerprint is not properly recognized Please try again after removing moistur...

Страница 7: ...ademic affairs management This product recognizes a person and saves the image at the point of recognition using a fingerprint By doing so it solves problems such as piracy due to illegal use and loss...

Страница 8: ...e added in places requiring higher security It offers the optimum solution for access control using various I O of IOMAN The CPU speed of the terminal is a very fast 400 MHz and through this high spee...

Страница 9: ...anual www bioinsec com 9 4 Product Diagram Speaker Voice Guide Fingerprint Built in Camera LCD Proximity Sensor Microphon Call Button Keypad Keypad Up Down Arrow Key Menu Clear Button Enter Reset Hole...

Страница 10: ...pearing when communication with the server is normal Icon showing when communication with the server is cut off DHCP mode setting in progress No Camera Icon Camera Off Camera Auto On SD Memory Card re...

Страница 11: ...a Mini SD memory Supports only 1GB 2GB SD memory is used for log and user backup Capable of mounting various external RF reader It can mount external RF readers such as MIFARE It can connect RF of oth...

Страница 12: ...larm connection and various I O Provides 2 relay contact points as basic option High Reliability using Fingerprint It has solved security problems due to card duplication loss and distribution arising...

Страница 13: ...ted to the independent program using SDK provided as a bundle CADENACIO can c onduct time attendance management with its own RTC and Log management fu nction Setting Viewing of User Time Zone It can b...

Страница 14: ...back to the previous menu Keypad Setting Button You can select the check box upon user registration It is hereinafter referred to as Star Button When deleting the input value it is used for the same...

Страница 15: ...CADENACIO User Manual www bioinsec com 15 This is used to complete or save a task It is hereinafter referred to as Enter Button...

Страница 16: ...tire Menu Tree The terminal is set as example menu tree when it left the factory If user changes the value set as factory next tree menu process will be changed with your purpose 1 User 2 Access Contr...

Страница 17: ...CADENACIO User Manual www bioinsec com 17 2 Access Control...

Страница 18: ...CADENACIO User Manual www bioinsec com 18 3 Network 4 Setup...

Страница 19: ...dministrator Password Registration In order to go into the menu administrator password must be registered The password when the product was shipped out is 1111 and you must change the password I Butto...

Страница 20: ...2 Enroll User Fingerprint Registration I Button Enter Password Default Value 1111 Button II User Enroll User Enter User ID Number Button III FP Check Once is pressed Repeat Check Uncheck Button IV Reg...

Страница 21: ...Button III Card Check If you press Repeat Check Uncheck Button Card gets close to number key Button IV Button Completed When changing the access mode once you press the relevant number you can check...

Страница 22: ...When changing the access mode once you press the relevant number you can check or uncheck it Please enter the password in 4 8 digits in order to prevent its leakage When setting with Fingerprint or Ca...

Страница 23: ...mode reregister after deleting a user I Button Enter Password Default Value 1111 Button II User Edit User Enter User ID Number Button V Enter Date to Change Impossible to change already registered ac...

Страница 24: ...button in the User ID input window the total number of registered users is displayed and they can be deleted together 3 Mode Setup Access Control Time Attendance Setu p Meals Setup 1 Access Control S...

Страница 25: ...n Mode is 1 Access Control Impossible to use in 2 Meal Mode Key It selects a button for using attendance code Select time attendance code with arrow keys or select using F1 F2 F3 and F4 as fixed keys...

Страница 26: ...ed if unnecessary 2 F1 Sign In Attendance Capable of Auto Setup of Time 3 F2 Sign Out After School Capable of Auto Setup of Time 4 F3 Out Early Leave 5 F4 Return Return 6 F5 7 F6 8 F7 9 F8 1 F0 is acc...

Страница 27: ...tton Enter Password Default Value 1111 Button II Access Control Operation Mode Mode Select Meal Mode III Button Finish Meal Setup It can be set in the time slot in the order of breakfast lunch dinner...

Страница 28: ...t saved and automatically deleted when it is changed to the next time slot 4 Prevention of Unnecessary Events in Attendance Meal Counting Mo de Event prevention is a setup menu for preventing the occu...

Страница 29: ...Control Use I O MAN Yes III Button Change Complete Please refer to installation manual on How to connect I O MAN 2 Link to Speed Gate Change of Door Opening Time Set door opening time to 0 5 seconds w...

Страница 30: ...is the identification number by terminal which must not be overlapped Upon network connection it is connected only when IP address and terminal ID matches I Button Enter Password Default Value 1111 Bu...

Страница 31: ...sh Normal Input Checking Procedure I IP Address Setup Yes II 1Automatic address receiving is successful when address is like 92 168 2 XXX III When is displayed select IP address setup No Input Manuall...

Страница 32: ...er Computer Reply OK No problem in communiction from terminal to server computer Time out No communication between terminal and server computer If Time out appears there is a problem in network settin...

Страница 33: ...l port speed of BioManager program For how to connect to RS485 please refer to installation manual 6 Camera Setup Camera is optional and does not apply to products without camera 1 Camera Operation Mo...

Страница 34: ...a Mode Select Automatic or On III Button Finish IV Camera Channel 0 Channel Finish 1 Auto is recommended for camera operation mode 2 Viewing with Camera Check if camera is properly working from the te...

Страница 35: ...ealer 7 Display This is the LCD setup menu 1 Lighting Hours Proximity sensor works in the terminal with camera option Default value is 10 seconds If a person approaches the camera it turns on in 10 se...

Страница 36: ...ssword Default Value 1111 Button II Setup Monitor LCD Contrast Change with Button III Button Finish 3 Brightness I Button Enter Password Default Value 1111 Button II Setup Monitor LCD Brightness Chang...

Страница 37: ...Password Default Value 1111 Button II Setup Monitor Black White Mode Select Yes III Button Finish While the authorization screen changes to black white mode the menu does not change 5 Set Time This i...

Страница 38: ...menu for setting the date format on the screen 1 No Screen is not displayed 2 MM DD Displays the date in the format of 8 13 FRI 3 DD MON Displays the date in the format of 13 AUG FRI I Button Enter P...

Страница 39: ...n II Setup Language Select English III Button Finish Only English and Korean is supported 8 SD Memory Backup Restore Micro SD Memory size supported is only 1GB or 2GB Unable to support more than 2GB T...

Страница 40: ...ou insert the SD memory into the terminal text files are automatically created for each month and are automatically saved without any setup process Log data Save log data to SD memory Image data Save...

Страница 41: ...II Button Finish Data in the terminal User ID Fingerprint Card Password Name and company number can be checked only in the program 4 Export to SD Memory This is a function which allows you to backup u...

Страница 42: ...r when there is an upgraded version If the version is different the registered data can be deleted I Menu Enter Password Default Value 1111 Button II System Import from SD Memory Firmware III Button S...

Страница 43: ...m Initialize Select out of Init Event Init Setup Init Factory III Button System Reboot IV Button Enter Password Default Value 1111 Button V Setup Language Korean VI Button Finish 10 Q A 1 I cannot vie...

Страница 44: ...mode the letters and time becomes a bit clearer I Button Enter Password Default Value 1111 Button II Setup Screen Black White Mode Yes III Button Finish 2 Card is not authorized when using Serial PC D...

Страница 45: ...Readers Setup Mifare Card Reader Reading Card Hold card close to keypad or fingerprint sensor Wiegand Wiegand III Button Finish 4 The fingerprint registered on the USB Fingerprint Device is not prope...

Страница 46: ...sure Set to 5 III Button Finish 5 The LCD screen keeps turning off and giving out a beep beep sound This may happen if the proximity sensor is activated or if the terminal without a built in proximity...

Страница 47: ...CADENACIO User Manual www bioinsec com 47 Enter Password Enter 0 Finish...

Страница 48: ...ith fingerprints of an individual Authentication Grade This is a standard grade for determining the authentication according to the similarity of fingerprints when comparing fingerprints Generally it...

Страница 49: ...It also has a function allowing the user to open the door during a phone conversation using a dial button on the phone Camera optional This is a camera module built into Cadenacio It takes photos when...

Страница 50: ...size 512 byte Registered Personnel 1 N user 3 000 persons RF card 10 000 persons Log data 100 000 data IN OUT port Input Door sensor Lock sensor Output Lock relay Exit button When linked up to I O MA...

Отзывы: