Bioenno Power SC-122420JUD Series Скачать руководство пользователя страница 4

STATUS CODES 

INDICATOR   STATE

 

DESCRIPTION  

MEANING 

CHARGE/ 
PANEL 

No Icons 

PANEL OFF, FUNCTION ICON OFF 

No Solar Panel detected 

Panel Icon On 
Function Icon  Off 

PANEL ICON ON, FUNCTION ICON 
NOT INDICATING 

Solar charging stopped 

Panel Icon On 
Function Icon On  

PANEL AND FUNCTION ICON ON, 
BATTERY ICON IS SCROLLING 

Solar Panels are 
charging Battery 

LOAD 

Function Icon On 
Light Bulb Icon On 

BOTH INDICATORS ARE ON SOLID  

Load is ON  

Function Icon Flashing 
Light Bulb Icon On 

LOAD INDICATOR ON, FUNCTION 
INDICATOR FLASHING 

Load is OFF 

BATTERY 

Battery Icon Empty 

NO BARS 

Battery requires 
charging 

Battery Icon Scrolling 

SCROLLING BARS 

Battery is charging 

Battery Icon Full 

FULL BARS, NO SCROLLING 

Battery is fully charged 

 

 

FAULTS AND REMEDIES 

 

 

 
Contact Us 
 

Mail

:     

Bioenno Power

                                              

E-mail

[email protected] 

            

3657 W. McFadden Ave. 

 

    

Phone

:

 +1 888 336-7864 

            Santa Ana, California 92704

 

ERROR CODE 

PHENOMENON 

REMEDY 

E01 

BATTERY LOW VOLTAGE 

CHECK OPERATION MODE, 
CONFIRM OPERATION MODE IS 
SET DEFAULT TO “AUTO” OR SET 
TO CORRECT VOLTAGE IF YOU 
ALREADY HAVE A SPECIFIC 
SYSTEM ASSEMBLED 

E02 

OVERLOAD, LOAD IS OFF 

DECREASE LOAD 

E03 

SHORT CIRCUIT, LOAD IS OFF 

REMOVE BATTERY AND LOAD, 
CONFIRM THERE IS NO REVERSE-
POLARITY, RE-ATTACH IN 
CORRECT CONFIGURATION 

E04 

OVERVOLTAGE ON BATTERY, 
LOAD IS OFF 

CHECK BATTERY, CONFIRM 
BATTERY IS APPROPRIATELY 
SIZED FOR APPLICATION 

E05 

OVERCURRENT ON SOLAR 
PANEL, CONTROLLER HAS 
STOPPED CHARGING 

CHECK PANEL OUTPUT, LOWER 
PANEL OUTPUT IF TOO HIGH 

*

Note

: In the event of a short circuit, your Solar Charge Controller trip an auto-reset fuse – disconnect load immediately, let it 

stand for 10-20 minutes, the internal fuse will automatically reset during this period. Before resuming operation, confirm your 
load does not exceed the 20A Maximum Load Current of your Solar Charge Controller. 

 