background image

Thank you for purchasing the 

Bioenno Power

BLF-2420A LiFePO4 Battery

Introduction

LiFePO4 chemistry is an evolution in rechargeable battery technology. It is safer, non-toxic, 
higher performing, and longer lasting compared to lead-acid batteries. Bioenno Power provides 
the highest quality LiFePO4 battery from our ISO9001 certified production facility that guarantees 
maximum performance. Please carefully review the information below as they are vital to the 
safety and performance of the battery.

Typical Applications

-

Energy Storage, E-Bike, E-Scooter, Motors, etc. 

Specifications

(summary)

For the full specification, please visit www.bioennopower.com

Caution

 Do not disassemble.
 Do not short circuit positive and negative terminals.
 Use only LiFePO4 compatible chargers. Do not use Lead Acid battery chargers, especially ones

with “anti-sulfation” features

 Do not submerge in water, the seal on the battery is not intended to withstand water pressure
 Do not throw in fire or dispose of improperly. Recycle the battery at a facility that accepts lithium 

battery

Last Revised 04/23/2018

Instructions for Use

Charging

1.

Only use 

29.2V, LiFePO4 compatible

chargers to charge the battery. The charging 

current should be 

2A to 4A

. If you need a charger, please contact us.

2.

Fully charge the battery 

before first use

.  This depends on the output of the charger but is 

typically between 3-5 hours.

3.

If your battery came with a Bioenno Power charger, please note that the 

LED light on the 

battery does NOT indicate the state of charge

. A red LED light means the battery is 

under constant current (CC) charging and green LED means constant voltage (CV) 
charging. Always charge for at least 5 hours to ensure full capacity.

4.

LiFePO4 does not suffer “memory effect” so please keep the battery fully charged for daily 
use. Cell balancing only occurs when the battery is fully charged (top-end balancing).

5.

Do not

charge the battery in temperatures below 0°C. This can cause damage to the cells.

Discharging

1.

Make sure your load accepts 24V nominal voltage.

2.

Ensure the connection between the battery and the load can handle the current draw. 
Please consult references for the appropriate wire type.

3.

The maximum continuous discharge current is 

20A.  

4.

The battery outputs a steady voltage around 25.6V until very little capacity remain, 

do 

NOT

rely on voltage as an indicator of remaining capacity.

Series and Parallel Connection

We do not recommend using our LiFePO4 batteries in series or parallel connection if a single 
battery of equivalent size can be used instead. The PCM/BMS built into each battery is intended 
only for operation with a single battery and we do not guarantee the operability of multiple 
batteries in series or parallel configuration. Please take the information below into consideration if 
you must use a series or parallel configuration.

Series: 

This battery will not operate in series configuration. 

Please do not use the battery 

in series.

Parallel: 

Only connect batteries with equal state of charge in parallel.

Also, measure the 

internal resistance of each battery and only use batteries with closely matched internal 
resistance. It is highly recommended that resistors be used to achieve equal internal 
resistance among multiple batteries. It is also highly recommended to add fuse(s) to 
the circuit for safety reasons.

Please keep in mind a series or parallel connection can fail with a number of consequences, from 
early cut off to possibly a fire. Always exercise caution and observe closely at all times. The 
customer assumes all responsibility in the event of a series or parallel connection or connections.

Maintenance and Storage

The battery requires no manual maintenance due to the included PCM/BMS. However, please 
follow the below guideline for best life cycle.
1.

Even though the LiFePO4 chemistry is relatively stable, protect the battery from shocks 
and drops to prevent internal short circuit.

2.

For long term storage, fully charge the battery and then discharge to 50% of the full 
capacity. 

Do NOT

leave the battery unattended for more than 6 months.

3.

For the best life cycle, avoid using the battery in extreme temperatures and avoid highly 
variable pulsing loads.

Dimensions    

9.3 in. x 3.2 in. x 5.8 in. (235 mm x 81 
mm x 147 mm) 

Weight 

11.2 lbs. (5.1 kg.) 

Battery nominal voltage   and  capacity 

24V, 20Ah  

Charging Voltage 

29.2VDC 

Charging Current 

2A~4A 

Open Circuit Voltage Range 

25VDC to 29.2VDC 

Maximum Continuous Discharge Current 

20A 

Maximum Peak Pulse Current  

40A (5 sec.) 

Operating Temperature 

- 10°C to 60°C 

Protection: 

PCM/BMS

 

Overcharge, overdischarge, overcurrent, 
temperature, balancing 

Terminal / connector type 

Charge Connector:  DC Plug 
Discharge Connector:  Anderson 
Powerpole 