NO
Setting Options
Data Setting Function
Factory Default
A1
Temp Calibration
-9-+9
℃
0.5
℃
A2
Temp Tolerance of Built in Sensor
0.5-2.5
℃
1
℃
A3
Temp Tolerance of External Sensor
1-9
℃
2
℃
A4
Children Lock
0: half lock
1: full lock
0
A5
Max temp of External Sensor
1. 35 -70
℃
℃
2. When setting temp is lower than
35 , screen display
℃
s
【
--
】
,
cancel
highest temp protection
--
A6
Min temp of External sensor
(anti-freeze protection)
1. 1-10
℃
2. When setting temp is higher than
10 , screen display
℃
【
--
】
,
cancel anti
freeze protection
5
℃
A7
Max Temp Setting
1-10
℃
5
℃
A8
Min Temp Setting
20-70
℃
35
℃
A9
Descaling function
0: Close descaling function
1: Open descaling function
(
Function
works for 3 minutes every no-operating
100 hours
)
0
AA
Power off Memory
0: Stay last state
1: Electricity turn off
2: Electricity turn on
0
AB
Weekly Programmable Function
P1: 5+2 days
P2: 6+1 days
P3: 7 days
P1
AC
Factory defaults
Display A o, long press until show the
whole screen
Advanced Setting
Power off state, long press for 3-5 seconds to do advanced setting. Short press to switch and confirm. Press
and to adjust options.
After finish setting , stand for about 5 seconds ,it will save setting then exit.
Setting IP code
Power off state, long press for 3-5 seconds to do advanced setting. Short press to switch and confirm. Press
and to adjust options.
After finish setting , standing for 5 seconds ,it will save setting then exit .
!
Considering battery usage, RF data updates every 20 minutes. If you wanna shorten interval, pls use USB
power and remove batteries. Follow B05, B06 operation.
NO
Setting Options
Data Setting Function
Factory Default
B1
IP code low setting
00-FF
00
B2
IP code high setting
01-FF
01
B3
IP matching code
Display”55” means IP match successfully.
(When receiver is power-on, press thermostat
successively)
00
B4
Sensor state
N1: single built-in sensor
N3: both built-in sensor and external sensor.
(when receiver with external sensor, this option is
automatically recognized and cannot be changed)
N1
B05
Minute interval of RF
transmission
1: 1-30 minutes
2: 0 B06
20 minutes
B06
Second interval of RF
transmission
3-30 seconds
30 seconds