2

 

 

HEALTH & SAFETY 

General safety 

This equipment has been designed to conform to the following directives 

2006/95/EC 

Low Voltage Equipment Safety Directive 

98/79/EC 

In Vitro Diagnostic Medical Devices Directive

  

2004/108/EC 

EMC Directive 

2002/96/EC 

EC Directive on Waste Electrical and Electronic Equipment (WEEE) 
2003/108/EC, 2008/34/EC 

2002/95/EC 

Restrictions of the use of certain Hazardous Substances in electrical and 
electronic equipment (ROHS) 

2006/42/EC 

Machinery directive 

1999/5/EC 

Radio and Telecommunications terminal equipment directive (instruments 
fitted with Bluetooth accessory only) 

 
 
Standards to which conformity is declared include 

 

EN61010-1:2001 Safety requirements for electrical equipment for measurement, control 
and laboratory use. 

 

EN 61010-2-101:2002 Particular requirements for IVD medical equipment 

 

EN 61326-1:2006 Electromagnetic compatibility - generic emission standard Electrical 
equipment for measurement, control and laboratory use. Classified as basic immunity 
criterion A and Class B for conducted and radiated emissions 

 

EN 12100-1,2:2003 (+A1:2009) Safety of machinery – Basic concepts, general principles for 
design 

 

EN 14121-1:2007 Safety of machinery, Risk assessment 

General Hazards 

There a number of warning labels and symbols on your instrument. These are there to inform you 
where a potential danger exists or particular caution is required. Before commencing installation, 
please take time to familiarise yourself with these symbols and their meaning. 

This instrument is intended for use by individuals trained in and familiar with the use of 
spectrophotometers and their associated hazards. In the event of a malfunction or hazard occurring, 
the user responsible shall disconnect the unit from power and isolate for decontamination and /or 
repair. 

This instrument is subject to the following hazards:  

 

High voltages exist inside the unit. Repair and maintenance should only be carried out by 

individuals  trained specifically to work on these instruments 

Содержание Libra S50

Страница 1: ...Biochrom Libra S50 S60 S70 S80 UV Visible Spectrophotometers Health Safety Manual...

Страница 2: ...ardous Substances in Electrical and Electronic Equipment ROHS 2006 42 EC Machinery directive 1999 5 EC Radio and Telecommunications Terminal Equipment Directive instruments fitted with Bluetooth acces...

Страница 3: ...Installation 4 Instrument Connections 5 Equipment Operation 6 Controls and Indicators 6 Intended Users 7 Instrument Preparation 7 Post Run Procedures 7 Performance Validation 7 User Maintenance 7 Tro...

Страница 4: ...ard Electrical equipment for measurement control and laboratory use Classified as basic immunity criterion A and Class B for conducted and radiated emissions EN 12100 1 2 2003 A1 2009 Safety of machin...

Страница 5: ...sure that the user of the equipment is provided with a safe working environment Any chemicals used in Analyses should be used stored and disposed of in accordance with manufacturer s guidelines and lo...

Страница 6: ...hen it should be allowed to come to thermal equilibrium for 2 to 3 hours before operation so that start up calibration is not compromised by condensation The equipment must be connected to the local s...

Страница 7: ...5 Instrument Connections...

Страница 8: ...m up and stabilise for at least 30 minutes If applicable connect the unit to a PC using a USB cable and refer to the online help and user manual Select the appropriate application or method Where rele...

Страница 9: ...nd solvents may be classified as hazardous or bio hazardous waste The disposal of such substances must be carried out in accordance with local regulatory practice Performance Validation Good laborator...

Страница 10: ...the online help or user manual TROUBLESHOOTING PROBLEM POSSIBLE CAUSE Start up calibration fails Check sample and reference beam is clear before switch on Possible optical failure contact service supp...

Страница 11: ...eb site or your local distributor Return the unit together with a completed declaration of contamination status form Available from the web site or your local distributor Please note that instrumentat...

Страница 12: ...10 41 56 1872 issue 01...

Отзывы: