background image

Blood Pressure Monitoring System

Owner’s Manual 

Model : 3160A-3

Blood Pressure Owner’s Manual

Blood Pressure Owner’s Manual

Blood Pressure Owner’s Manual

Blood Pressure Owner’s Manual

Dear 3160 System Owner :

Thank you for purchasing the Blood Pressure Monitoring System. This system is a fully 

automatic, digital blood-pressure measuring device for use on the upper arm, it enables 

very fast and reliable measurement of the systolic and diastolic blood-pressure as well as 

the pulse frequency by way of the oscillometric method of measuring.

This manual provides important information to help you operate this system correctly. 

Before using this product, please read the following contents thoroughly and carefully.

With the compact size and easy operation of this Blood Pressure Monitoring System, you 

can easily monitor your blood pressure by yourself at any time or place. In addition, this 

system can help you and your healthcare professionals to monitor and adjust your 

treatment plans, and keep your blood pressure under control. 

If you have other questions regarding this product, please contact the place of purchase.

       

         Type BF applied part.                 Read the instructions carefully before using this device.

  

IMPORTANT SAFETY PRECAUTIONS

READ THIS BEFORE USE

1. Use this device 

ONLY

 for the intended use described in this manual.

2. Do 

NOT

 use accessories which are not specified by the manufacturer.

3. Do 

NOT

 use the device if it is not working properly or damaged.

4. Do 

NOT

 use the equipment where aerosol sprays are being used, or where oxygen is 

     being administered.

5. Do 

NOT

 use under any circumstances on newborns.

6.This device does 

NOT

 serve as a cure for any symptoms or diseases. The data measured 

   are for reference only. Always consult your doctor to have the results interpreted.

7.Keep the equipment and its flexible cord away from hot surfaces.

8.Do 

NOT

 apply the cuff to areas other than the place directed.

9.Do 

NOT

 remove plastic wrapping membrane to ensure the waterproof  function.

10.Proper maintenance and periodically calibration are essential to the  longevity of 

      your device. If you are concerned about your accuracy of measurement, please 

      contact local customer service for help.

KEEP THESE INSTRUCTIONS  

BEFORE YOU BEGIN

INTENDED USE

The 3160A-3 system is a system designed to measure the systolic and diastolic blood 

pressure and pulse rate by using a non-invasive technique in which an inflatable cuff is 

wrapped on the upper arm. It is intended for individuals age 18 and above for use at home 

and in clinical settings. The device is not to be used for the diagnosis of hypertension or for 

testing on newborns.

TEST PRINCIPLE

Blood pressure is measured non-invasively at the upper arm based on oscillometric 

method. If you have been diagnosed with a severe arrhythmia or irregular heartbeat, atrial 

or ventricular premature beats or atrial fibrillation, measurements made with this 

instrument should only be evaluated after consultation with the doctor or your healthcare 

professionals. 

Electromagnetic interference

The device contains sensitive electronic components. Avoid strong electromagnetic fields 

in the direct vicinity of the device (e.g. mobile phones, microwave ovens. Electrical 

interference can lead to temporary impairment of the measuring accuracy).

MONITOR OVERVIEW

Device

3160 offers a wide range fan-type cuff, measuring size : 

22~38cm, suitable for most of arm circumferences; 

Large cuff (measuring range 32~42cm) is available as

special accessories.

          Do not use accessories or equipment which are 

          not certified  by manufacturer, they might increase 

          emissions or decrease  immunity of this system. 

DISPLAY SCREEN

ADVANTAGES OF AUTOMATIC BLOOD PRESSURE 

MONITOR  

Blood Pressure Rate Indicator.

Blood pressure rate indicator is located along the left side in the display. The classification 

corresponds to ESH (European Society of Hypertension) ranges described in the table of 

the section «7.1. reference values».

After the measurement, there appears the color bars in the left part of the display: green 

zone - optimal blood pressure, yellow - elevated, orange - too high, red – dangerously 

high. This function helps you to self-orient in the measurement results.

CAM technology – Clinically Accurate Measurement

CAM Technology - Clinically Accurate Measurement - provides you with the maximally 

accurate results of blood pressure measurement at home. Cardiologists recommend 

always take several repeated measurements and calculate their average values. The device 

in the CAM mode automatically takes 2 measurements in succession, analyzes the results 

and displays the ready values.

Irregular Heartbeat Detection Advanced

I

HB advanced is an oscillometric waveform technology which is more sensitive, but not 

specific, to identify varying rhythm symptom such as skipped heartbeats, abnormally 

rapid (Tachycardia), or slow (Bradycardia) pulse and Atrial Fibrillation occurring during the 

measurement, while regular IHB (Irregular Heart Beat) feature in the market is to detect a 

condition where the heartbeat rhythm varies by more than certain percentage from the 

average heartbeat detected during the measurement, If the symbol of IHB advanced 

appears on the display that means that certain abnormality in heart beat frequency was 

detected during the measurement. In this case, the result may deviate from your normal 

blood pressure – repeat the measurement. In most cases, this is no cause for concern. 

However, if the symbol appears on a regular basis (e.g. several times a week with 

measurements taken daily) we advise you to tell your doctor.

Please show your doctor the following explanation :

Information for the doctor on frequent appearance of the Irregular Heartbeat

Detector This instrument is an oscillometric blood pressure monitor that also

analyses pulse frequency during measurement. The instrument is clinically tested.

The symbol is displayed after the measurement, if pulse irregularities occur during

measurement. If the symbol appears more frequently (e.g. several times per week

on measurements performed daily) we recommend the patient to seek medical 10 

advice. The instrument does not replace a cardiac examination, but serves to detect

pulse irregularities at an early stage.

SETTING THE MONITOR          

Before using your monitor for the first time, check and update these settings. Make sure 

you complete the steps below and save the desired settings.

INSERT BATTERIES

After you have unpacked your device, first insert the attached 

batteries (4 x size AAA 1.5V) with the indicated polarity. The battery 

compartment is located at the bottom side of the device (see 

illustration).

NOTE

• After the warning            appears, device is blocked till the batteries have been replaced. 

• Please use «AAA» 1.5V Batteries. 

• If the blood-pressure monitor is left unused for long periods, please remove the batteries.

USE A MAINS ADAPTOR

The 3160 Series Blood Pressure Monitor can be operated with a mains adapter (output 5 V 

DC / 600 mA). 

a. Connect the micro plug to the socket at the device right side.

b. Plug the mains adapter (output 5 V DC / 600 mA) to a 100-240V electrical power socket.

ENTER THE SETTING MODE

Insert batteries or press the O/I button at the back

side of the device, then touch and hold M/SET

button for 3 seconds until the “2013” flashes on

the upper right corner.

SETTING THE DATE AND TIME

a. When the year flashes, press M/SET button until the

    correct year appears.Press CAM button to confirm 

    and change to Month setting.

b. When the month flashes, press M/SET button until

    the correct month appears. Press CAM button to 

    confirm and change to date setting.

c. Set the day, hour and minute in the same way as 

    described above.

SETTING THE ALARM

This 3160 Series upper arm blood pressure monitor allows you to set 

2 alarm clocks as a reminder to take medication or measurements.

a. Device in standby status, hold M/SET then hold CAM button. Release

    both buttons, “1” flashes on the screen, press M/SET button to toggle

    between alarm “1” and “2”.

b. Touch CAM button, hour flashes, touch M/SET button to set the 

    desired hours and touch CAM button for the next minute setting.

c. At the time of alarm, the meter beeps automatically. You can touch

    any button to silence it immediately.

How to switch off the alarm permanently : 

hold CAM button when the 

alarm number “1” or “2” is flashing, release as “On” is changed to “OFF” 

on the display

NOTE :  The alarm times must be re-entered each time the batteries are 

replaced.

USER NUMBER SELECTION.

This 3160 Series system supports measurement for two users. Before 

measurement, make sure you set the unit for the intended user: device 

in standby status, hold START then M/SET button, till user icon switches

to another one.

TESTING YOUR BLOOD PRESSURE

BEFORE MEASUREMENT

• Avoid caffeine, tea, alcohol and tobacco for at least 30 minutes before measurement.

• Wait 30 minutes after exercising or bathing before measurement.

• Sit or lie down for at least 10 minutes before measurement.

• Do not measure when feeling anxious or tense.

• Take a 5-10 minutes break between measurements. This break can be longer if necessary, 

   depending on your physical condition 

• Keep the records for your doctor as reference.

• Blood pressure naturally varies between each arm. Always measure your blood pressure 

  on the same upper arm.

FITTING THE CUFF PROPERLY

a. Plug the cuff connector to the cuff socket on the device left side.

b. Assemble the cuff as shown below. The smooth surface should be inside of the cuff loop

    and the metal D-ring should not touch your skin.

c. Stretch your left (right) arm in front of you with your

     palm facing up. Slide and place the cuff onto your 

     arm to let the air tube and artery mark region toward 

     the lower arm. Wrap and tighten the cuff above your 

     elbow. The artery mark on the edge of the cuff should 

     be approx. 0.8" to 1.2" (2 cm to 3 cm) above your elbow.

     Align the tube over the main arteries on the inside. 

d.Leave a little free space between the arm and the cuff : 

    you should be able to fit two fingers between them. 

    Remove all clothing covering or constricting the

    measurement arm.

e. Press the hook material firmly against the pile material. 

    The top and bottom edges of  the cuff should be 

     tightened evenly around your upper arm.

PROPER MEASUREMENT POSITION

Sit down for at least 10 minutes before measuring.

a. Place your elbow on a flat surface. Relax your hand with 

    the palm facing up.

b. Make sure the cuff is about the same height as the location

     of your heart.

c. Press the O/I button to switch on the monitor.

d. Remain still and do not talk or move during the measurement.

WARNING If the cuff is relatively lower (higher) than the heart, the obtained blood pressure 

value could be higher (lower) than the actual value. A 15 cm difference in height may result 

in an error around 10 mmHg.

TAKING MEASUREMENTS

TAKING A SINGLE MEASUREMENT

Always apply the pressure cuff before turning on the monitor.

a. Turn on the monitor by pressing the O/I button at the back side.

 O/I button

 Cuff socket

 M/SET Button

 CAM Button

 Start Button

 Battery Compartment

 DC Jack

 LCD Display

 Air Tube

 Air Plug

    Cuff

     

1.Time Date

2. Alarm Clock

3. Systolic Pressure

4. Diastolic Pressure

5. Low battery Icon

6. Pulse Rate

7. AF Icon

8. CAM Mode

9. Heartbeat Icon

10. Irregular Heartbeat Detector

11. Memory Set

12. Memory Icon

13. Night Time Icon

14. Day Time Icon

15. Traffic Light Indicator

16. User Icon

Blood Pressure Owner’s Manual