User Manual of Oxygen Concentrator - CP501T 

 

4

 

1 humidification bottle.   

1 Oxygen Outlet Connector 

     

Front View

Figure 1

 

1.

 

Display Panel 

2.

 

Intake Filter 

3.

 

Accessories container 

4.

 

Circuit breaker –

selected units

  resets the unit after electrical overload shutdown. 

5.

 

Flow meter knob 

6.

 

Flow meter 

7.

 

Power Switch 

I =ON          O=OFF 

8.

 

Oxygen outlet—oxygen is dispersed through this port 

9.

 

Nebulization function

optional

 

10.

 

Wheels 

 

Back View

Figure 2

 

11.

 

Filter sponge — prevents dirt, dust, and lint from entering your unit

 

12. Product specification label 

13. Exhaust

under unit

 

14. Power cord and /or IEC power connector 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                     

 

 

 

 

 

BACK View

Figure 2

 

11 

6

10 

FRONT View

Figure 1

 

12 

13 

14 

Содержание CP501T

Страница 1: ...Oxygen Concentrator CP501T Oxygen Concentrator Instruction Guide WARNING Read instruction guide before operating this equipment DANGER NO SMOKING ...

Страница 2: ......

Страница 3: ...P501T OXYGEN CONCENTRATOR WORKS 3 IMPORTANT PARTS OF YOUR CONCENTRATOR 3 SETTING UP YOUR OXYGEN CONCENTRATOR 5 BEFORE OPERATING YOUR OXYGEN CONCENTRATOR 6 OPERATING YOUR CP501T CONCENTRATOR 7 CARING AND PERIODIC MAINTENANCE FOR YOUR UNIT 7 MINOR TROUBLESHOOTING 10 SPECIFICATIONS 11 SYMBOL 12 ELECTROMAGNETIC IMMUNITY 13 DECLARATION OF CONFORMITY 15 ...

Страница 4: ... medical advice before using an oxygen concentrator is advisable Physician Information Physician Name Telephone Address Prescription Information Name Oxygen liters per minute at rest during activity other Oxygen use per day Hours Minutes Comments Oxygen Concentrator Serial Number CP501T check one 3 Liter 5 Liter 8 Liter 10 Liter Provider Information Service Person This instruction guide was review...

Страница 5: ...SCRIBED SUPPLEMENTAL OXYGEN Today many people suffer from heart Lung and other respiratory diseases Many of these people can benefit from supplemental oxygen therapy Your body requires a steady supply of oxygen to function properly Your physician prescribed supplemental oxygen for you because you are not getting enough oxygen from room air alone Supplemental oxygen will increase the amount of oxyg...

Страница 6: ...ical overload shutdown 5 Flow meter knob 6 Flow meter 7 Power Switch I ON O OFF 8 Oxygen outlet oxygen is dispersed through this port 9 Nebulization function optional 10 Wheels Back View Figure 2 11 Filter sponge prevents dirt dust and lint from entering your unit 12 Product specification label 13 Exhaust under unit 14 Power cord and or IEC power connector BACK View Figure 2 11 2 6 6 7 8 1 10 FRON...

Страница 7: ...CE 19 Alarm red light TURN this device OFF and contract your device supplier for service immediately SETTING UP YOUR OXYGEN CONCENTRATOR 1 Position your unit near an electrical outlet in the room where you spend most of your time DANGER Keep the oxygen concentrator at least 5 feet 1 6 m from hot sparking objects or naked sources of flame NOTE Do not connect to an electrical outlet controlled by a ...

Страница 8: ...ure I b Fix humidifier to machine with a rubber band connected humidifier to intake port in one side and connected humidifier to machine oxygen outlet in other side See Figure 2 Figure 5 Figure 6 3 Remove the power cord completely from the line cord strap Make sure the power switch is in the off position and insert the plug into the wall outlet the unit is double insulated to guard against electri...

Страница 9: ...sure that the flow meter ball is centered on the line next to the prescribed number of your flow rate CAUTION It is very important to follow your oxygen prescription Do not increase or decrease the flow of oxygen consult your physician NOTE Your Medical provider may have preset the flow meter so that it can not be adjusted NOTE If the flow meter knob is turned clockwise the flow decreases and even...

Страница 10: ... the concentrator cabinet The cabinet should only be removed by a qualifier Medical technician Do not apply liquid directly to the cabinet or utilize any petroleum based solvents or cleaning agents Clean the concentrator exterior cabinet by using a damp cloth or sponge with a mild house hold cleaner and wipe it dry Periodic Maintenance for Your Unit 1 Clean the Air Filter Sponge at least once a we...

Страница 11: ...tact your Medical provider The OCI Device is a device within your concentrator that monitors the oxygen produced by your unit When the units is turned ON all four light Power Low Oxygen Normal Oxygen and Service Required on the front panel will illuminate briefly After a few seconds only the Power and Normal Oxygen lights will remain lit The lights on the front panel are defined as follows Green N...

Страница 12: ...er bottle Detach the humidifier from the oxygen outlet If proper flow is obtained clean or replace humidifier 5 Flow meter set too low Set flow meter to prescribed flow rate If the above remedies do not work contact your Medical provider C Unit operates the power light is on when power switch is on audible low frequency vibration sound is detected Turn your unit off Switch to your reserve oxygen s...

Страница 13: ...s Rating Medical Device Category Class II Insulation Rating B In Compliance With EU Medical Device Directive 93 42 EEC Approvals Certifications CE No 0434 RoHS SFAD Operating Environment Temperature 10º C 40º C Humidity 30 to 75 Atmospheric Pressure 86 kPa 106 kPa Storage Transportation Temperature 20º C 55º C Humidity up to 93 non condensing Atmospheric Pressure 86 kPa 106 kPa Oxygen Concentratio...

Страница 14: ...term within 3 years the machine should be treated on local law or regulation requirement To avoid hurt users and pollute environment The equipment bears CE mark CE0434 indicating its conformity with the provision of Council Directive 93 42 EEC concerning medical devices and fulfills the essential requirement of Annex I of this directive FRAGILE Contents of the transport package are fragile therefo...

Страница 15: ...d d is the recommended separation distance in metres m b Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not ap...

Страница 16: ...User Manual of Oxygen Concentrator CP501T 14 b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m ...

Страница 17: ... DECLARATION OF CONFORMITY Manufactured Bio Medical Instruments Systems Product Designation Oxygen Concentrator Model Number CP501T EC authorized representation CGI Business Trading Inh Herr Leizhang Huegel Str 73 60433 Frankfurt am Main Germany ...

Отзывы: