CAUTIONS BEFORE INSTALLATION:
WIRING REQUIREMENT
•
THIS PRODUCT MUST BE PLUGGED
into a regular voltage grounded
GFCI outlet (North America 120V ac). The rated power consumption is
1400W. In locations where only a standard two-prong outlet is available,
it is the responsibility of the user to install a grounded three-prong outlet.
Using a higher voltage is dangerous and may result in a fire or other
accident. This product is not responsible for damage resulting from
the use of it on other than specified voltage, or operating it without
proper grounding.
WARNING
•
This product must be on a separate circuit. No other appliance should
share the circuit with this product. Sharing a circuit could cause the
branch circuit fuse to blow or the circuit breaker to trip. Continuous
usage under these conditions could result in fire or property damage.
GROUND INSTRUCTIONS
1. This product has a three-prong grounding plug, which must be plugged
into an outlet that is properly installed and grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. If repair or replacement
of the cord or plug is necessary, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having an outer surface
that is green with or without yellow stripes is the grounding wire. Check
with a qualified electrician or service person if the grounding instructions
are not completely understood, or if in doubt as to whether the product
is properly grounded.
2. This product is for use on a nominal 120V circuit, and has a grounding
plug that looks like the plug illustrated in sketch A in Figure 1. A
temporary adapter, which looks like the adapter illustrated in sketches
B and C, may be used to connect this plug to a 2-pole receptacle as
shown in sketch B if a properly grounded outlet is not available. The
temporary adapter should be used only until a properly grounded outlet
(sketch A) can be installed by a qualified electrician. The green colored
rigid ear, lug, or the like extending from the adapter must be connected
to a permanent ground such as a properly grounded outlet box cover.
Whenever the adapter is used, it must be held in place by the screw.
OPTIONAL GROUND INSTRUCTIONS