11

WATER DRAINGE METHODS

This product has a self-evaporative system. The condensing water

will recycle to cool the condenser. This water-cooled mode can not 

only improve cooling efficiency and decrease noise, but also save 

energy for you.

* When in cooling mode, the water from the evaporator will flow into a inside

pan. When the water reaches the low level, the water pump will work until

the water is under the low level. When the water reaches the high level, the

compressor will stop working, and the water pump, lower fan motor and

upper fan motor will work on all the time.

* When in heating mode, the water pump won't work.

* When the water is full, the water full indicator will light and the compressor 

will stop working. The buzzer will buzz 10 times every 5 minutes until the

water is below the high level or drained by hand. When the alarm stops and

after three-minutes restart delay, the unit will

work normally.

* You can drain the water out with a drain pipe. It

is included in the accessory. But first you 

should put some vessel like pan under the 

hose, then take out the plug on the drain mouth,

thus the water will flow into the vessel and 

won't make the floor wet. (Fig.13) If the

drainpipe is shorter than you need, you can 

purchase a pipe (9mmI.D.). Then connect it to

the drainpipe with the drainpipe kit we supply.

* Move the unit gently when the water is high. If

not , the water may spill from the inside of the unit.

* When the water in the cave is not enough for pumping, the pump will stop 

working. At the same time, the Water Injection indicator on the control panel
will illuminate ( ), you had better inject some water into the water draw

carefully. In order to avoid the water flooding from the under pan, you should

inject water not more than 1800ml (three cups). This operation helps save 

20%-30% energy for you.

MAINTENANCE 

Cleaning 

Switch

 the unit 

OFF 

and pull the plug 

from 

the socket before any cleaning

 or 

maintenance

Clean the surface of the unit with a 

damp,

 soft cloth. Do not use 

harsh 

detergents, solvents, abrasives or 

chemical

s

Clean

ing

 the 

A

ir 

F

ilter

s

If the air filter is 

dirty

, the efficiency 

of  the  unit

 reduce

s

It is 

recommended to c

lean the filter

s

 every 

two weeks. 

1)

Pull

 

out the air filter

s

 

(

Fig.14

)

.

2)

Wash the filter

s

 in warm

 

(under 40

°

C

 

or 104

°F

)

 water, with a neutral 

detergent, then rinse and allow to dry 

in a shaded area. 

3) Push the air filter back into the

original position.

Storage

 

1.  Drain

 the unit

, then run the fan at low speed for 6 to 8 hours to dry the 

inside of the unit.
2.  

Switch the unit 

OFF 

and disconnect the 

electrical cable

 from the power 

supply.

3.  

Remove the air exhaust duct

ing. Be careful not to kink or distort it.

4.  Cover

 the unit and keep it in a dry place.

5.  Remove

 the batteries 

from

 the remote control.

4

PARTS LIST 

1. control panel

2. horizontal louver

3. vertical louver

4. air inlet grille

5. castor

6. exhaust duct

7. handle

8. air outlet grille

9. power cord and plug

10. water injection port

11. power  and  hook 

12. air  filter 

Содержание PA300

Страница 1: ...USER MANUAL PORTABLE AIR CONDITIONER 48mm 15mm...

Страница 2: ...SUPPLY 240V 50Hz 1 8MPa 4 5MPa 2 0MPa 5 5MPa 450m h 52dB A 31 kg 318 710 528mm COOLING 1400W 1460W HEATING RATED INPUT AIR FLOW NOISE NET WEIGHT PERMISSIBLE EXCESSIVE OPERATING PRESSURE SUCTION DISCHA...

Страница 3: ...it is correct Change the fuse switch unit on Change or switch off the timer Drain water Cooling heating efficiency not good Is the air inlet or outlet blocked or filters dirty Are there any other heat...

Страница 4: ...t use the appliance for any other purpose than its intended use The appliance must not be used if the guards are not fastened according to instructions When the power cord is damaged it must be replac...

Страница 5: ...ng water will recycle to cool the condenser This water cooled mode improves cooling efficiency and decreases noise and also saves energy When in Cool mode the water from the evaporator will flow into...

Страница 6: ...detergent then rinse and allow to dry in a shaded area 3 Push the air filter back into the original position Storage 1 Drain the unit then run the fan at low speed for 6 to 8 hours to dry the inside...

Страница 7: ...and position as required Dehumidifying Use the Mode button to select Dry mode The fan speed automatically is set to low cannot be changed and the display shows the current room temperature NOTE In Coo...

Страница 8: ...Celsius and Fahrenheit Press to activate Cool mode Press to activate Heat mode Press to activate Dry mode Press to activate Fan mode Up Press to set temperature or adjust time in Down Timer mode High...

Отзывы: