L.2. Quartz sleeve dismounting
Every year
you must check that the quartz sleeve has not became opaque due to scale deposits. It should be
completely transparent
not to reduce the UV radiations.
1.
The sterilizer MUST be POWERED OFF, BY-PASSED and fully
DRAINED.
Once by-passed and powered off, the reactor can be drained by
loosening the lower union.
2.
Remove the lamp (see previous paragraph)
3.
Remove the sealing washer by unscrewing the 3 screws with an Allen
key (size 2.5).
4.
Remove carefully the quartz sleeve :
Insert a thumb or finger in the sleeve and withdraw it gently until the
seal comes free from its housing, while remaining well aligned with the
axis.
5.
Take hold of the quartz sleeve and extract it fully, making sure that you
keep it CORRECTLY aligned with the axis.
6.
If whitish calcium deposits are present, you must clean it. This is done
using spirit vinegar or acid and a soft cloth.
The quartz must not be
scratched as this would change the ultraviolet radiation qualities.