BIO RAD PowerPac HV Series Скачать руководство пользователя страница 48

Life Science
Group

    Sig 1212

10002468 Rev D     US/EG

Bio-Rad 
Laboratories, Inc.

Web site 

www.bio-rad.com  

USA 

800 424 6723  

Australia 

61 2 9914 2800  

Austria 

01 877 89 01  

Belgium 

09 385 55 11 

Brazil 

55 11 5044 5699  

Canada 

905 364 3435  

China 

86 21 6169 8500  

Czech Republic 

420 241 430 532  

Denmark 

44 52 10 00  

Finland 

09 804 22 00  

France 

01 47 95 69 65

  

Germany 

089 31 884 0  

Greece 

30 210 9532 220

  

Hong Kong 

852 2789 3300  

Hungary 

36 1 459 6100  

India 

91 124  4029300   

Israel 

03 963 6050  

Italy 

39 02 216091  

Japan 

03 6361 7000  

Korea 

82 2 3473 4460  

Mexico 

52 555 488 7670  

The Netherlands 

0318 540666  

New Zealand 

64 9 415 2280  

Norway 

23 38 41 30  

Poland 

48 22 331 99 99  

Portugal 

351 21 472 7700  

Russia 

7 495 721 14 04  

Singapore 

65 6415 3188  

South Africa

 27 861 246 723  

Spain 

34 91 590 5200  

Sweden 

08 555 12700  

Switzerland 

026 674 55 05  

Taiwan 

886 2 2578 7189 

 Thailand 

800 88 22 88   

United Kingdom 

020 8328 2000

Содержание PowerPac HV Series

Страница 1: ...PowerPac HV Power Supply Instruction Manual Catalog Numbers 164 5056 and 164 5059...

Страница 2: ......

Страница 3: ...Pac HV displays the software version momentarily after switching the power ON State clearly the error code error message or anomaly and the conditions that originated the problem including run paramet...

Страница 4: ......

Страница 5: ...er supply must be kept away from wet surfaces Avoid splashing or leaking solutions into the power supply 3 Always connect the power supply to a grounded AC outlet An acceptable power cord is provided...

Страница 6: ......

Страница 7: ...un in Manual Mode 12 4 2 Basic Methods Mode 14 4 2 1 Create Edit and Run a Basic Method 15 4 3 IEF Methods Mode 18 4 3 1 Create Edit and Run an IEF Method 19 4 4 Temperature Mode 22 4 4 1 Create Edit...

Страница 8: ...ds Connected Incorrectly 5 Figure 7 Menu Overview for Manual Operation 11 Figure 8 Menu Overview for Basic Methods Mode 14 Figure 9 Menu Overview for IEF Methods 18 Figure 10 Menu Overview for Tempera...

Страница 9: ...imiting parameter Output range Voltage 20 5 000 Volts V Adjustable in 0 1 V increments from 20 0 to 99 9 V Adjustable in 1 V increments from 100 to 5000 V Current 0 05 500 mA Adjustable in 0 01 mA ste...

Страница 10: ...editing running parameters Automatic detection of no load short circuit rapid resistance change ground leak fan failure and system overheating Automatic completion if desired of a run interrupted by...

Страница 11: ...with the carrier in accordance with their instructions before contacting Bio Rad Laboratories Unpack the PowerPac HV Remove the plastic film from the translucent green top case The plastic film may le...

Страница 12: ...time mode hours volt hours or untimed Up down Used to scroll through method list or method protocol An asterisk is arrows and used to identify the selected method or step The up arrow is used to deci...

Страница 13: ...r cord rear of the instrument Connect the other end to a compatible power source 2 Connect cells Insert power leads into one of the output terminals located on the front of the power supply shown to t...

Страница 14: ...enable and disable safety features and infrared IR port as well as LCD display contrast adjustment key sound and set local time and date Step Procedure Description 1 Open the Setup editor Press SETUP...

Страница 15: ...corner of the Run screen Warning Turning the power supply off Stopping a run in progress with PFd enabled is regarded as a power failure The interrupted run will resume automatically when the power i...

Страница 16: ...ound and the error code 01 to be displayed see Section 6 3 For example if an electrophoresis cell is not connected or the current is too low less than 0 02mA for Manual or Basic Methods and 0 005mA fo...

Страница 17: ...when Temperature Probe Check Default the temperature probe is connected OFF ON The run is paused and error code 18 is displayed in case of failure A failure occurs when the temperature remains 5 C les...

Страница 18: ...IEF Methods Nine 9 methods with up to nine 9 steps can be stored This mode allows direct programming for high voltage low current applications also allows voltage ramping and run delay see Section 4...

Страница 19: ...rform a run in Manual mode Fig 7 Menu Overview for Manual Mode EDIT LIMITS 100 V 500 mA 400W TIME UNTIMED _______ CONSTV LIMITA LIMITW S1 1 EDIT TIME 200 V 500 mA 500W TIME UNTIMED____________ HRS VHR...

Страница 20: ...the Use the soft keys to select a nonconstant nonconstant parameters parameter and the keypad to enter its value Press EDIT key twice to go back to step 3 CONSTV A or W Press CONST soft key to change...

Страница 21: ...the elapsed time versus the programmed time timed runs elapsed time untimed run voltage current and power values 8 Pause Press the soft key PAUSE or the key to pause the run in progress The run param...

Страница 22: ...__________ OPEN DELETE NEW METHOD SDS PAGE S1 10V 00 30 HRS S2 200V UNTIMED S3 EMPTY ________________________ METHODS DELETE SAVE S1 1 EDIT LIMITS 200 V 500 mA 400W TIME UNTIMED _______ CONSTV LIMITA...

Страница 23: ...ed method Select a stored method using the arrow scroll keys and press the DELETE Soft key An asterisk indicates the selected method Note If the method list is full nine methods a method needs to be d...

Страница 24: ...Operates with constant current CONSTW Operates with constant power Press EDIT to continue 7 Enter limits for the Use the soft keys to select a parameter and the non constant alphanumerical keypad to...

Страница 25: ...the run Press to start a run 11 Monitor the run The RUN screen is used to monitor run parameters or to pause a run The current step Volts mA and Watts values elapsed time versus the programmed time an...

Страница 26: ...ig 9 Menu Overview for IEF Methods IEF METHOD LIST pH 3 10 IEF EMPTY ____________________________________ OPEN DELETE NEW METHOD PH 3 10 S1 100V 00 30 HRS S2 800V 05 30 HRS S3 EMPTY ________ METHOD DE...

Страница 27: ...ow scroll keys an asterisk indicates the selected method and press the OPEN soft key Go to step 4 to edit method otherwise go to step 11 to start the run DELETE a stored method An asterisk indicates t...

Страница 28: ...ected step 6 Set the Voltage profile Use the V MAX soft key to enter the maximum voltage value with the keypad for the current step Use the V SLOPE soft key to select the voltage ramping slow linear o...

Страница 29: ...Add a new step or save To program additional steps press the down arrow the method key to select the empty step and repeat steps 5 9 If the method will not be saved start the run Press SAVE and then...

Страница 30: ...ature to 90 C The PowerPac HV monitors the temperature of the electrophoresis cell through the temperature probe catalog 165 5058 attached to the wall of the cell The temperature of the cell is contro...

Страница 31: ...on 3 3 4 for additional information on TEMP PROBE options 5 Set temperature limit Use the alphanumeric keypad to enter the desired temperature 30 90 C Press the EDIT soft key to continue 6 Enter param...

Страница 32: ...y To edit the run parameters during PAUSE see step 6 To Edit preference see Section 3 Edits made during the run may be saved if SAVE soft key is pressed at the end of the run Otherwise the method will...

Страница 33: ...nal run If the current step started as untimed it cannot be changed to hours or volt hours Fig 11 Menu Overview for Editing a Paused Method RUN S2 4 216 V 235 mA 50 W 00 02 00 30 32HRS____ PAUSE RUN P...

Страница 34: ...or Manual run editing Section 4 2 for Basic Methods editing Section 4 3 for IEF Methods editing Section 4 4 for Temperature mode run editing Use the CONTINUE soft key or to resume the run 3 Exit the R...

Страница 35: ...onal computer PC either directly from the power supply or through a PDA Using the PDA with PowerPac Remote methods can be created stored and beamed to and from the PowerPac HV The PDA may also be used...

Страница 36: ...tem 400 MHz processor 256 MB RAM minimum 512 MB recommended 1 024 x 768 screen resolution with true color mode 24 or 32 bits 10 GB hard drive CD ROM drive Infrared IR port or adaptor Minimum PDA speci...

Страница 37: ...he fuse may need to be replaced 1 Disconnect the power cord from the electrical outlet 2 Use a slot head screwdriver to press the tabs on the side of the fuse holder toward each other This will releas...

Страница 38: ...e 2 Replace the fuse See Section 6 1 1 for details Repeatedly blown fuses Hardware failure Contact Bio Rad Technical Support Leads from the cell are Some leads are not The PowerPac HV not not long eno...

Страница 39: ...levels are wrong connections appropriate ERROR STOP CODE 03 Connection to an Press the CONTINUE soft OVER VOLTAGE external source or key to continue the run CORRECT AND CONTINUE control circuitry RUN...

Страница 40: ...chiller system for leaks Verify that the electrophoresis cell rests on an insulated and dry surface Check power source connections Additional capacitance from external EM filters or an uninterruptibl...

Страница 41: ...Hardware Turn power supply off and on then 19 99 malfunction restart run If problem persists contact Bio Rad Technical Support Contacting Technical Support For Technical Support Contact your local Bi...

Страница 42: ...Real time clock Yes Automatic recovery after power failure Yes user selectable setup values maintained Data transfer archiving Yes Temperature control Yes via temperature probe 30 90 C 2 C Microampere...

Страница 43: ...by Bio Rad Laboratories for this power supply Deliberate or accidental misuse Damage caused by disaster For inquiry or request for repair service contact your local Bio Rad office Warranty Informatio...