EMS Unit x 1
Electrodes x 4
Leadwire x 2
9V Battery, type 6F22 x 1
Instruction Manual x 1
Carring Case x 1

PRODUCT CONFIGURATION

INSTRUCTION MANUAL

for the

MAXEMS 2000

Manufactured by

   

Bio Protech  Inc.

Donghwa Medical Instrument complex, 151-3, Donghwagongdan-ro,  Munmak-eup, 

Wonju-si, Gangwon-do, 26365 Korea     Tel: 82-33-735-7720 , Fax : 82-33-735-7736

Made in China.                                                                                  Rev.005  05/2017

       CAUTION

  

Federal Law (U.S.A) restricts this device to sale by or on the order of a physician.

Содержание MAXEMS 1000

Страница 1: ...NSTRUCTION MANUAL for the MAXEMS 2000 Manufactured by Bio Protech Inc Donghwa Medical Instrument complex 151 3 Donghwagongdan ro Munmak eup Wonju si Gangwon do 26365 Korea Tel 82 33 735 7720 Fax 82 33...

Страница 2: ...ECIFICATION 9 ACCESSORIES 10 GRAPHIC SYMBOLS 11 ATTACHMENT OF ELECTRODE LEAD WIRES 12 LEAD WIRE MAINTENANCE 13 ELECTRODE OPTIONS 14 ELECTRODE PLACEMENT 15 TIP FOR SKIN CARE 16 APPLICATION OF RE USABLE...

Страница 3: ...erating machinery or during any activity in which involuntary muscle contractions may put the user at undue risk of injury Chapter 5 ADVERSE REACTIONS Skin irritation and burns beneath the electrodes...

Страница 4: ...2 Pulse Amplitude Adjustable by intensity control knob Adjustable 0 80mA peak into 500 ohm load each channel 3 Output Voltage Adjustable by intensity control knob Adjustable 0 40V peak into 500 ohm l...

Страница 5: ...r your condition Follow application procedures outlined in electrode packaging to maintain stimulation and prevent skin irritation Use of legally marketed adhesive EMS electrodes is recommended EMS el...

Страница 6: ...lling stress tape extra lengths of lead wires to the skin in a loop to prevent tugging on electrodes 6 When removing electrodes always remove by pulling in the direction of hair growth 7 It may be hel...

Страница 7: ...must be switched off before connecting the cables Both intensity controls must be at the off position Electrodes must be pressed firmly on the skin 4 Function Selector Expose the controls by sliding f...

Страница 8: ...setting value to 0 When the ramp time is set each contraction may be ramped in order that signals come on and come off gradually and smoothly The ramp time is adjustable from 1 second to 8 seconds by...

Страница 9: ...her until the patient experiences a strong but comfortable tingling sensation 10 This intensity should not be painful Protocol for the safe termination of EMS 1 Gradually slowly decrease the intensity...

Страница 10: ...essary insert a new battery 4 For possible damage to the cable Change the cable if any damage is detected If there is any other problem please return the device to your distributor Do not try to repai...