Bio-Net Air Purifier
TM
Operation:
Plug the unit into a standard 120 volt earth grounded AC circuit and depress the
speed button to Low, Med or High. The control panel lights should be illuminated
as follows:
EGF Main Filter - green light is ON (Functioning)
EGF Bio Monitor - green light is ON (Functioning)
When the unit is operating properly, both indicator lights will be
"
green
"
.
EGF Main Filter Service Light:
When the Green/Function light goes OFF and the Red/Service light goes on, this
is your indication to
"
replace
"
the Main EGF Filter. The maximum life expectancy
of the Main EGF Filter is 24 months. See Main EGF Filter replacement instruc-
tions.
The Reversible Multi-Stage Filtration contains Carbon/Zeolite Media plus Dual 10
micron Pre-filters which can be vacuumed, reversed and then reinserted in be-
tween filter changes to prolong the life of the filter. However, the Reversible Multi-
Stage Filtration System needs to be replaced at least every 12 months. **
EGF Bio Monitor Light:
Green light ON indicates that airborne microorganisms are continuously being
destroyed in the EGF Filtration Grid System. If the light goes OFF, microorgan-
ism destruction has been interrupted. Immediately turn off the unit and unplug it
from the outlet.
Cleaning the Unit: (Periodically you should clean the Pre-filter).
Before cleaning the unit, shut the air purifier OFF and unplug it from the outlet.
Clean exterior surfaces only with a soft cloth dampened with water. Do not use
abrasive cleansers. Do not spray the unit with any liquid cleaner. Wipe the intake
grill weekly with a clean, dry non-static cloth. To clean the Pre-filter, see next
page. If you hear a loud crackling sound then the grid needs to be cleaned, (see
trouble shooting guide).
***NOTE: People with chemical and environmental (MCS) sensitivities will
detect contaminants at lower levels and will have to change their filters sooner.
1.Turn the air purifier off and unplug from power outlet.
2.To access EGF Main Filter, place fingertips under side
recesses of black cover, gently pull outward and lift cover
up to remove. Separate cover from the air purifier.
(Fig. A)
To Change Reversible Multi-Stage Filtration:
4.To remove EGF Main Filter, lift fil-
ter from the internal chamber. (Fig.
C). Before installing the new EGF
Main Filter, make sure the black fil-
ter seal
"
O
"
ring is seated properly
in the
"
O
"
ring channel (Fig.D). The
EGF Filter is labeled with
"
FRONT
"
this must be positioned to the front
of the unit. (Fig.C)
(Fig. C)
(Fig. B)
(Fig. A)
(Fig. D)
(Fig. E)
Control Panel Guide
3. To release EGF Main Filter, move
both black handles 90
0
toward front
of air purifier. (Fig.B). Do not force
the handles.
To Change EGF Main Filter:
(Fig. F)
(Fig. G)
1. Turn the air purifier off and unplug from power outlet. To change/vacuum Carbon Filter, Open
back panel (Fig.F) remove panel and set it down. Pull out Carbon Tray (Fig.G) and replace
every 12 months. If your have high levels of particulates in your home and/or animal hair you
can easily vacuum the Pre-Filters, between filter changes, which are located on the underside
of the Carbon Tray, see (Fig.H). Simply vacuum the Carbon Tray Pre-filter. Then turn the tray
over and reinsert into filter drawer. This procedure can be repeated as necessary, however, it is
highly recommended that this entire filter be replaced annually.
2. Reattach back panel. Your unit is now ready for use.
(Fig. H)
Carbon/Z Dual Pre-Filtration Tray
6.To replace the
cover
, align the vertical tab, on the inside of the
cover
, with the slot in the top of
the
machine
behind the front panel
. Push down gently and snap shut. Plug air purifier into power
outlet and turn on. (Fig . A)
Note: The unit will not run with top attached improperly.
5.To load EGF Filter, align hole in filter tab with brass contact (Fig.E). Press filter down.
To lock filter in place, move both black handles in 90
o
toward the center of the filter.
CAUTION: Do not force handles, they should move freely, if not, realign filter.