background image

5

Remove the 

Bio-Logic

®

Pure Water Pack

from shipping carton.

Atlantic Ultraviolet Corporation takes all possible 
precautions when packaging this unit to prevent 
damage. Carefully inspect the water purifier, power 
cord and plug for damage, report all damage 
immediately. Do not assemble or operate if there is 
any damage, visible or suspected.

Units occasionally experience damage in shipment 
due to the fragility of the quartz sleeve, it is 
recommended that the water purifier be inspected 
for damage to the quartz sleeve. Each end of the 
unit should be viewed to see if the quartz sleeve has 
experienced damage. If the quartz sleeve shows 
signs of damage it should be replaced before the 
purifier is pressurized. See “

Quartz Sleeve 

Cleaning or Replacement

” in the “

Maintenance

” 

section for the proper method of replacing the quartz
sleeve in your water purifier.

The 

Bio-Logic

®

Pure Water Pack

is shipped 

with the lamp packed separately. Keep the lamp 
aside for installation once the 

Pure Water Pack

has been properly installed.

Carefully inspect all packing materials to prevent 
the loss of accessories, mounting hardware, spare 
parts or instructions.

Do not discard packing materials until unit is 
assembled and check out is complete.

The 

Bio-Logic

®

Pure Water Pack

includes:

Pure Water Pack

system, with installed:

Bio-Logic

®

Ultraviolet Water Purifier

Associated mounting brackets

10" Filter Housings

5 micron Sediment Filter Cartridge

Activated Carbon Filter Cartridge

Saddle Valve with hardware

Stainless Steel Faucet with hardware

John Guest

¼" OD Tubing Connectors

1/4" OD Tubing, 24-inches long

1/4" OD Tubing, 15-feet long

120v 60Hz, 220v 50/60Hz or 12v DC Ballast

Ultraviolet Germicidal Lamp

Filter Housing Wrench

Operating Instructions

Figure 2 - 

Bio-Logic

®

Pure Water Pack

- Drinking Water System

UNPACKING

Содержание BIO-1.5

Страница 1: ...auge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at www ultraviolet com Document No 98 1124B6 Revised December 2010 2002 2010 Atlanti...

Страница 2: ...instructions generally describe the installation operation and maintenance of the Bio Logic Pure Water Pack Questions that are not specifically answered by these instructions should be directed to th...

Страница 3: ...RUCTIONS WARNING To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL safety instructions 2 Do not use this system for other than its inten...

Страница 4: ...flow through the disinfection chamber exposing it to the germicidal lamp Exposure time is related to the flow rate the higher the flow rate the lower the exposure time or the lower the flow rate the h...

Страница 5: ...thod of replacing the quartz sleeve in your water purifier The Bio Logic Pure Water Pack is shipped with the lamp packed separately Keep the lamp aside for installation once the Pure Water Pack has be...

Страница 6: ...t be connected to the cold water line only 4 The system should be located as close to the faucet as possible 5 CAUTION As with any water handling device the water purifier should be located in an area...

Страница 7: ...turning the T handle clockwise until it is firmly seated The valve is CLOSED in this position 4 Open the cold water supply valve or main valve check for any signs of leaks around valve connection 5 In...

Страница 8: ...Lifting the handle of the faucet will lock the faucet in the ON position while holding the handle down the faucet is ON the faucet well shut off when the handle is released Slowly open the saddle valv...

Страница 9: ...se of this system For any questions concerns or technical assistance regarding this system or any of our other products contact our application specialists Contact options can be found in the User Ass...

Страница 10: ...er purifier 2 Shut off water supply to the system by closing the supply valve Open the system faucet and allow the system to drain 3 Release the pressure in the filter housing by pressing the red pres...

Страница 11: ...to water purifier until lamp and both easy off end caps have been properly reinstalled 7 Reattach the ground connector to the grounding tab of the chamber and restore power to the system DISPOSAL OF M...

Страница 12: ...ochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals 8 Reassemble in reverse order Make sure the quartz sleeve protrudes an equal distance past each thread...

Страница 13: ...the head clamp around the flared ends of the head and chamber Install the 1 4 nut and tighten using a 7 16 wrench until approximately 7 8 to 1 of the bolt protrudes past the nut 11 Carefully insert qu...

Страница 14: ...ir bubbles Water contains black particles New carbon filter cartridges Open system faucet allow water to run purging the contain activated carbon carbon particles from the cartridge until water is cle...

Страница 15: ...John GuestTM Connector Number of Lamps 1 Lamp Model No 05 1366 R Quartz Sleeve Yes Length 14 1 2 Width 5 3 4 Height 18 Shipping Weight 18 Lbs Voltage c 120V 50 60Hz Power Consumption d 14 Watts Max O...

Страница 16: ...16 REPLACEMENT PARTS Bio Logic ULTRAVIOLET WATER PURIFIER Figure 10 Exploded View Bio Logic 1 5...

Страница 17: ...1 10 1201A 3 Germicidal Lamp 1 05 1366 R 4 Static Gland Nut 2 25 1492D 5 Teflon Washer 2 25 3023A 6 Rubber O ring Quartz Sleeve 2 00 1023A 7 Quartz Sleeve 1 15 1700A 8 Chamber Head 2 with Ground Termi...

Страница 18: ...18 REPLACEMENT PARTS Bio Logic Pure Water Pack Figure 11 Exploded View Bio Logic Pure Water Pack...

Страница 19: ...4509 9 Male Connector x3 8 NPTF John Guest 4 25 4513 10 Pipe Nipple 3 8 x1 Long PVC 1 25 4510 11 Tubing OD x 24 Long 1 25 4515 12 Saddle Valve fits 3 8 Copper Tubing 1 25 4511 13 Faucet Long Reach Sp...

Страница 20: ...E No attempt has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in this publication of any design or method of use which may be patent...

Отзывы: