Section 5a

 – TROUBLESHOOTING

 

 

TROUBLESHOOTING 

 

PROBLEM

 

 

CAUSE

 

SOLUTION 

 

1) 

Insufficient SANITIZER Production.

 

 

A)

  The test kit reagents or test strips are old or expired. 

A) 

Retest with new Reagents or Strips. 

B) 

The unit is set too low in relation to SANITIZER demand. 

B)

  Turn up the output setting. 

 

C)

  The circulation run time is insufficient. 

C) 

Increase your pump run time. 

 

D)

  The bather load has increased. 

D) 

Same solution as 

(B)

 or add a Non-Chlorine Shock  

 

   

  containing 

Potassium 

Monopersulfate to supplement. 

 

E)

  The body of water being sanitized leaks. 

E) 

Repair the leak and rebalance as needed. 

 

F)

 Low Salt. 

F)

  Check the residual salt level and adjust as needed. 

 

G)

 “Cell Power” selection not matched to the cell installed. 

G)

  Follow the SET UP procedures to match the cell, see page 7. 

 

H)

  SANITIZER loss due to intense sunlight 

H)

  Check your stabilizer level and adjust if needed. 

2) 

Scale Build-up within the Cell.

 

 

A) 

The water being sanitized contains high pH, total 

A)

  Calculate Saturation Index to assure balanced water.  

 

 

alkalinity and calcium hardness levels. 

 

Adjust chemicals and clean the Cell.  See pages 9 & 11. 

 

 

(Cell scales within 2 – 3 weeks) 

 

B)

  Power Supply not reversing polarity. 

B)

  Contact the factory for Warranty Status/Procedures. 

 

 

(Cell constantly scales within 3 – 5 days) 

3) 

DC Plug and Cell Terminals Burned.

 

 

 

A)

  The Cell terminals are wet due to a leaking cell body. 

A)

  Contact the factory for Warranty Status/Procedures. 

 

B) 

The Cell plug is not securely pushed onto the cell 

B) 

Ensure the Cell cord plug is pressed completely onto the 

 

 

terminals, allowing moisture to seep into the plug. 

 

Cell terminal.  Check the terminals and clean with a dry  

 

 

   

 

 

cloth to remove all dirt and corrosion. 

4) 

Premature Cell Failure (Requires Replacement Cell).

  

 

 

A)

  Abnormally high Cell usage due to an insufficient 

A) 

Check the stabilizer level and adjust to recommended levels. 

 

 

Stabilizer (Cyanuric acid) level. 

 

B)

  Excessive Scale/Debris in the Cell. 

B) 

See Section 2 above.  

 

C) 

“Cell Power” selection not matched to the Cell installed. 

C)

  Follow the SETUP procedures to match the cell, see page 7. 

5) 

White Flakes in the Water.

 

 

A)

  This occurs when excessive calcium hardness is 

A)

  Visually inspect Cell for scale build-up and clean the cell as 

 

 

present.  Usually due to water chemistry imbalance. 

 

described on page 11.  Adjust your water chemistry. 

6) 

No Power to the Control Box.

 

 

A)

  Internal Fuse blown. 

A)

  Check and replace fuse.  See page 10. 

 

B)

  Circuit Breaker tripped. 

B)

  Check the power going to the Control Box.  Reset the  

  

 

 

 

Circuit 

Breaker. 

7)

 

SERVICE Light (Single RED Flash and Flow-OK light off).

 

 

 

A) 

 

Tri-Sensor Defective. 

A)

  Contact the factory for Warranty Status/Procedures. 

 

 

B) 

 

Insufficient Flow Min. (94.5 L/min) 

(25 US Gallons/min) 

B)

 

Ensure your Filter and Cell are clean of debris. 

 

   

   

 

Check all valves that might divert flow away from the cell. 

8)

 

SERVICE Light (Double RED Flash)(SANITIZER is producing).

 

 

 

A) 

  High Cell Volts with Low Amps 

A)

  Check cell for calcium build-up or scale deposits. 

 

   

   

 

Cell is depleted and needs replacement. 

 

   

   

 

Cell cord is loose or defective.  Ensure that the cord is firmly  

 

   

   

 

attached to the cell.  Check the Banana Plug connections. 

9)

 

SERVICE Light (Triple RED Flash)(SANITIZER production halted). 

 

(Microprocessor version V1.4 or older)  

 

 

A) 

High Cell volts with

 

Extremely Low Amps. 

A)

  Heavily scaled cell or failed cell. 

 

(Microprocessor version V1.5 or newer)  

 

 

A) 

Improperly wired or failed Power Supply. 

A)

  Ensure voltage input matches wiring connection (page 5). 

10)

 

SERVICE Light (Quadruple RED Flash)(SANITIZER is producing). 

 

A) 

Tri-sensor or tri-sensor cord is loose or defective. 

A)

  Inspect and tighten or replace.  

11)

 

LOW SALT Light activated (SANITIZER is producing) .

 

 

A)

  Salt level Low (below 2,5 g/l (2500 ppm)). 

A)

  Check with Salt test strips or meter and adjust as needed. 

12)

 

ADD SALT Light activated (SANITIZER production halted).

 

 

A)

  Salt level extremely low (below 2.0 g/l (2000 ppm)). 

A)

  Check with Salt test strips or meter and adjust as needed. 

13)

 

Unable to set output to a high level.

 

 

A)

  Temperature is too low (below 15.6C (60F)). 

A)

  The Pool Pilot has limited output to protect the cell.  

 
 

13

Содержание 28069

Страница 1: ... Controls Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor use RETAIN MANUAL FOR FUTURE REFERENCE NSF50 C IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This control product is to be used only in accordance with the directions on this label It is an offense under the Pest Control Products Act to use a control product under unsafe conditions Bio ...

Страница 2: ..._________________ Control Unit Control Unit Model Number ST60______________ Serial Number ____________________________ Cell Model Number RC 13 Serial Number ____________________________ Customer Assistance HOTLINE 1 800 268 6572 or 905 686 8836 FAX 905 619 8696 Manufactured for Bio Lab Canada Inc 1005 Copperstone Drive Pickering ON L1W 4A5 Pool Pilot Soft Touch by BIO LAB CANADA INC 1 ...

Страница 3: ...try in accordance with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adult supervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Pool Pilot Soft Touch to connect a minim...

Страница 4: ... Sensor Connections ORP Connections 2c Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Control Panel 7 3b Pool Water Preparation 8 Salt Requirement Chart Start Up Procedures 8 3c Monitoring and Maintenance 9 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Servicing 10 Control Box Tri Sensor 4b Servicing ...

Страница 5: ... Remove the cover by following the steps pool or spa instructions to remove and inspect on page 10 to access the mounting See page 8 for salt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 77 kg 1 68 lbs of free available chlorine day 230 VAC 1 5 AC amps RC 13 CELL Cell Power Level 3 8 amps DC 50 60 Hz Cell Lif...

Страница 6: ...Gr Yel Br Bl 2 pin ORP Cell Cord AC Line In Plug Plug 1 6 5 4 3 2 Connector Connectors Pool Pilot AC Line IN CONTROL BOX BASE PLATE AC LINE IN Wiring diagram also located on inside of cover For 230 VAC Brown Br Line 1 Blue Bl Line 2 Green w Yellow Tracer Gr Yel Earth Ground For 115 VAC Brown Br Line Blue Bl Neutral Green w Yellow tracer Gr Yel Earth Ground The AC Line IN wiring is pre set for conn...

Страница 7: ...ify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf ball in the strainer screen uni...

Страница 8: ...r water chemistry parameters monthly and compare to the Saturation Index WARNING Changing the Reversing cycle to SHORT will also reduce cell life However operating the cell under scaled conditions on Normal or Long is more detrimental to the life of the cell and changing the Reverse cycle is suggested The BOOST Button activates the Boost light when it is pressed once This light indicates that the ...

Страница 9: ...ies TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL Pool Volume in Liters US Gallons SALT Level Before Addition 3 780 1 000 9 430 2 500 18 900 5 000 28 300 7 000 37 780 10 000 56 700 15 000 75 600 20 000 113 600 30 000 0 ppm 11 3 25 28 63...

Страница 10: ...odium hypochlorite and does not affect the calcium hardness or total alkalinity levels Maintain and balance only as needed CYANURIC ACID STABILIZER CONDITIONER This chemical goes by either trade name and allows the chlorine residual to last longer by protecting it from the UV degradation of the sun With low or no Cyanuric acid it is possible for the chlorine to be used up as quickly as it enters t...

Страница 11: ...trol Circuit lift off metal cover electrical connections remove these board removes with cover fuses and pump aux relay Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 Control Panel Circuit Board Fuse 3 Amps 250 VAC F3 Cell Fuse 20 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons mi...

Страница 12: ...h a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use a non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the calcium is being neutralized and ...

Страница 13: ...l Unions and Cord ordered separately 12ft 3 6m Cell Cord 952 1 Union O Ring 19013 Cell RC 13 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately Directional Flow Indicator View of locking Quick connect heads 12ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Direction of Water Flow Temperature Sensor Post Sal...

Страница 14: ...B See Section 2 above C Cell Power selection not matched to the Cell installed C Follow the SETUP procedures to match the cell see page 7 5 White Flakes in the Water A This occurs when excessive calcium hardness is A Visually inspect Cell for scale build up and clean the cell as present Usually due to water chemistry imbalance described on page 11 Adjust your water chemistry 6 No Power to the Cont...

Страница 15: ...se of salt the top light is not used the next to the top flashes the 1000 s digit and the third light flashes the 100 s digit in ppm Example 2 flashes pause 8 flashes pauseRead 2 800 PPM 2 The second value is the water temperature in degrees Fahrenheit When this is displayed the second light from the bottom is on The top light flashes the 100 s digit the next the 10 s digit and the next the units ...

Страница 16: ...READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING Imported to Canada for BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 REGISTRATION NO 28069 PEST CONTROL PRODUCTS ACT MINERAL SPRINGS SOFT TOUCH MODEL ST60 Chlorine Generating Device One ST60 unit can treat a maximum of 190 000 Liters of swimming pool water Notice to User This control product is to be used only i...

Страница 17: ...REGISTRATION NUMBER 28069 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual of the chlorine generating device MINERAL SPRINGSModel DIGITAL 60 or MINERAL SPRINGSModel Soft Touch ST60 before using BIO LAB CANADA INC 1005 Copperstone Drive Pickering ON L1W 4A5 MINERAL SPRINGS Cell Label for DIG ...

Страница 18: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Отзывы: