EN - 3
Welding torch B
1 Designated use
1 Designated use
MIG/MAG manual welding torches are used to safely weld low and high-
alloy materials. They consist of the torch neck with equipment parts and wear
parts, handle or handle tube and cable assembly with central connector. They
conform to EN 60 974-7 and are not considered devices that independently
fulfil functions. Arc welding can only be carried out in connection with a
welding power source.
2 Technical data
Transport and storage
-25°C to 55°C
Relative humidity
Up to 90% at 20°C
Tab. 1
Ambient conditions during operation
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN 439)
CO
2
and mixed gas M21
Wire types
Commercially available round
wires
Voltage rating
Peak value of 113 V
Protection type of the machine-side connections
(EN 60 529)
IP3X
Tab. 2
General torch data (EN 60 974-7)
Type
Type of
cooling
Load
DCY Wire
Gas flow
Cooling data
Supply
temp.
Flow Flow
pressure
CO
2
M21
Max.
Min.
Min.
Max.
A
A
%
mm
l/min
°C
l/min
bar
bar
B 15
Air
180
150
60
0.6 - 1.0
10 - 18
B 24
Air
250
220
35
0.8 - 1.2
10 - 18
B 25
Air
230
200
60
0.8 - 1.2
10 - 18
B 36
Air
300
270
60
0.8 - 1.2
10 - 20
B 501 D
Liquid
500
450
100 1.0 - 1.6
10 - 20
40
1
2.5
3.5
Tab. 3
Product-specific torch data (EN 60 974-7)