![BINZEL-ABICOR BRS-CC Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/binzel-abicor/brs-cc/brs-cc_operating-instructions-manual_2753025039.webp)
BRS-CC
10 Dismounting
EN - 18
9.3 DAV wire cutting device
10 Dismounting
Dismounting may only be carried out by qualified personnel. Please make sure that the shutdown
procedures are strictly observed, before the dismounting work begins. Ensure this also for the components
integrated into the welding system.
1
Unscrew the screws and remove the cleaning unit and the collecting tray.
2
Unscrew the screws and the assembly stand from the floor.
11 Disposal
For the maintenance station
BRS-CC
to be properly disposed of, it first must be dismounted. For disposal,
the local regulations, laws, provisions, standards and guidelines must be observed.
See chapter 10 Dismounting on page EN-18
Fault
Cause
Solution
No cutting function
• Compressed-air supply / hose connection
interrupted
• Directional valve Y3 does not switch
• Valve actuator does not move
• Check all supply lines leading to the cylinder
and the screwings
• Check signal output of robot control
• Replace directional valve Y3
Insufficient cutting capacity
• Too low working pressure
• Rough-running slide
• Dirty cutting edge
• Worn cutting edge
• Check the adjustment of the pressure regulator:
min. 4 bar/max. 8 bar
• Dismount movable parts, clean and oil them
• Clean more often
• Clean
• Change approach position P1
• Changing the cutter
Free wire end is bent
• The wire has no contact to the fixed jaws
• Counter support jammed
• Correct the approach position of the welding
torch
• Dismount movable parts, clean and oil them
• Tighten the mounting screws
Tab. 17
DAV faults and troubleshooting
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair work, the following instructions
must be adhered to:
• Switch off the power supply and close off the compressed air supply.
• Switch off the entire welding system.
• Pull the mains plug.
NOTE
• Observe the information given in chapter 7 Putting out of operation on page EN-16.