background image

4.7 Laser product

Use only trained and qualified personnel to install or replace this device.

Chose SFP+ transceivers that meet the following regulations:

• Class 1

• Application of CE marking in accordance with the 2014/30/EU EMC and the

2014/35/EU Low Voltage Directives

• IEC/EN 60950-1, IEC/EN 60825-1 and IEC/EN 60825-2 European standard

• FCC 21 CFR Chapter 1, Subchapter J (in accordance with FDA and CDRH re-

quirements)

• UL and/or CSA registered component for North America

• 47 CFR Part 15, Class A

bintec elmeg

4 Compliance

RM7000

23

Содержание RM7000

Страница 1: ...RM7000 Installation Manual Copyright bintec Dm667 I Version 2 5 06 2020 bintec elmeg bintec elmeg Manual RM7000 1 ...

Страница 2: ...intec elmeg offers no warranty whatsoever for information contained in this manual bintec elmeg is not liable for any direct indirect collateral consequential or any other damage connected to the de livery supply or use of this manual Manual bintec elmeg 2 RM7000 ...

Страница 3: ... 1 2 Hardware monitoring 4 Chapter 3 Components and Power Supply 5 3 1 Components 5 3 1 1 Front panel 5 3 1 2 Rear panel 7 3 2 Expansion slots 8 3 2 1 Compatible cards 9 3 3 Installation in a rack 10 3 3 1 Standalone 11 3 3 2 Wall mounting 11 3 4 Plug in modules 11 3 4 1 Installation 11 3 4 2 Uninstall 11 3 5 Power source 12 3 5 1 Internal power source 12 3 5 2 PoE source 13 3 6 RST button 15 3 6 ...

Страница 4: ... Information 24 A 1 Troubleshooting 24 A 2 Updating the software 24 A 3 Connecting to the device 24 A 3 1 Connecting using the local console Aux connector 24 A 4 Connectors 25 A 4 1 LAN connector switch 25 A 4 2 WAN Base T connector 26 A 4 3 WAN SFP connector 26 A 4 4 USB connector 26 A 4 5 Configuration connector 27 A 5 Technical specifications 27 A 5 1 Hardware architecture 27 A 5 2 LAN interfac...

Страница 5: ...I Related Documents bintec Dm748 I Software Updating bintec elmeg Related Documents RM7000 1 ...

Страница 6: ... Power supply requirements Elements that can be connected when the router is operating How to install and uninstall the modules and power sources A description of the device LEDs and connectors Troubleshooting 1 5 What is not in this manual This manual does not contain information relative to the device software or its configuration For information on how to configure this device please see the re...

Страница 7: ...Fax 49 911 688 0725 Email support bintec elmeg com bintec elmeg 1 About this Guide RM7000 3 ...

Страница 8: ...age 12 2 1 2 Hardware monitoring The LEDs on the front panel are used to monitor the hardware in the RM7000 router These LEDs provide visual in formation on the state of the device and reference the condition of the hardware components indicating whether there is connectivity data flow etc For further information on the LED panel please see Components on page 5 2 RM7000 bintec elmeg 4 RM7000 ...

Страница 9: ...s follows Front panel components Item Description A LED panel B Slot 1 for expansion card C Slot 2 for expansion card D Slot for hard disk The LED panel provides information on the status of the components whether they are active or not and on network activity LEDs LED Definition Status Indication PSU Power Switch On Off Off No power through PSU On Powered through PSU S General Status Default Conf...

Страница 10: ... Not used SFP Green Connected Blinking connection data activity Off Not used Cell Status Not supported Not supported Not supported SIM Not supported Storage HD SD HDD SDD Status Off Hard disk or SD card is not connected or is inactive Green Detected hard disk or SD card Amber Testing hard disk or SD card Red Error Apps Apps Information Off No applications detected Green Applications detected Amber...

Страница 11: ...Link detected Blinking con nection data activity 3 1 2 Rear panel The following figure shows the rear panel Here you will find the majority of the RM7000 router connectors Fig 3 Rear panel The following table provides information on each connector as well as a description Rear panel components Item Description A Power source connection PSU B Wi Fi Antenna connectors Not supported C 3G Antenna conn...

Страница 12: ... front panel as shown in the following figure Fig 4 Expansion slots To correctly insert cards please follow these steps 1 Switch off the device and remove the data cables as described under section Disconnecting on page 12 2 Remove the device from the workplace and place it in a stable safe location where it can be easily accessed and handled 3 Unscrew the front panel screws to remove the expansio...

Страница 13: ... bintec elmeg com for a list of updated expansion cards Depending on the card type it can be plugged in any expansion Slot or only in the Slot 1 The following table lists the different models of cards that can be installed in Slot 1 or Slot 2 without restrictions RM7000 Slot 1 and Slot 2 compatible cards Code Description RCTMATS1 One serial port card synchronous asynchronous RCTMATS2 Two serial po...

Страница 14: ...0A48 R7B RCTMATG8W One port G SHDSL card 4 pairs CABLE INCLUDED 1 x RJ11 2m RCTMATVADSL One port VDSL ADSL card CABLE INCLUDED 1 x RJ11 2m RCTMATVASFP One port VDSL ADSL one port SFP card CABLE INCLUDED 1 x RJ11 2m RRCTMAT4GE1SFP One port SFP 4 GE ports RCTMAT4GE 4xGE card 3 3 Installation in a rack The RM7000 can be installed in a 19 rack The necessary strips and screws are not provided by defaul...

Страница 15: ...ot be mounted on the wall 3 4 Plug in modules Currently only a 3G USB modem can be inserted in the device To view the list of supported 3G modems please go to the following website http www bintec elmeg com 3 4 1 Installation Simply insert the USB in the appropriate slot on the rear panel as shown in the following figure Fig 11 USB modem insertion slot 3 4 2 Uninstall To remove the device simply p...

Страница 16: ...in Connecting on page 12 andDisconnecting on page 12 3 5 1 Internal power source To connect the power supply to the device please follow the steps under section Connecting on page 12 To avoid electric shocks residual current circulation and other unwanted effects that affect communications the fol lowing is recommended Warning All interconnected communication devices should be plugged to THE SAME ...

Страница 17: ...cover that protects the access to the MiniPoE card Fig 13 Removing the screws from rear panel 4 Once the screws have been removed slide the cover along and lift it up and off Place it in a safe location 5 Locate the area where the MiniPoE card must be placed Fig 14 MiniPoE card Location 6 Place the MiniPoE card so that it matches the three connectors This operation must be carried out carefully wi...

Страница 18: ...TY ENGINE 0x0a120500 POE CARD 0 GIGABIT ETHERNET 1 PCI device PowerPC processor RC Bus 0 Device 0 Function 0 Vendor 0x1957 Device 0x0840 Subs Vendor 0x0000 Subs Device 0x0000 SLOT1 PCI device Ethernet controller Bus 1 Device 0 Function 0 Vendor 0x8086 Device 0x1537 Subs Vendor 0xFFFF Subs Device 0x0000 PCI device PowerPC processor RC Bus 10 Device 0 Function 0 Vendor 0x1957 Device 0x0840 Subs Vend...

Страница 19: ...s default configuration through the following steps With the device switched off press and hold the RST button down while you turn the router on using the ON OFF switch 1 The PSU LED green will light up and LED S will begin to blink amber It will carry on blinking for 10 seconds To boot the device with the default configuration let go of the RST button while LED S is still blinking i e before the ...

Страница 20: ...t from the switch and is handled as just one more interface Please pay careful attention to the labeling to avoid confusing these ports with other types of port Fig 19 WAN connectors Note During booting and in BIOS mode the WAN connectors do not work 3 7 3 Connecting a 3G USB device USB connector The RM7000 router has a USB HOST 2 0 Type A connector interface It allows 3G USB modems to be connecte...

Страница 21: ...ction Disconnecting on page 12 2 Remove the device from the workplace and place it in a stable and safe location where it can be easily ac cessed and handled 3 Unscrew the screws on the front panel to extract the tray for hard disk access Fig 22 Unscrewing the screws from the front panel tray 4 Once unscrewed pull out the tray from the front panel slot Fig 23 Extracting the tray from the front pan...

Страница 22: ...Screw the tray to the front panel 8 Connect the equipment as indicated in section 3 5 1 1 Connecting Connect the terminal to the console and check that the device detects the hard disk 3 8 2 Procedure to install a flash memory expansion SD To install an SD card insert it into the SD tray as shown in the following figure 3 Components and Power Supply bintec elmeg 18 RM7000 ...

Страница 23: ...Fig 27 Inserting SD card bintec elmeg 3 Components and Power Supply RM7000 19 ...

Страница 24: ...facturer bintec elmeg Country Germany Postal Address Suedwestpark 94 90449 Nuremberg Germany International Phone 49 911 9673 0 4 2 Safety warnings Connecting Discon necting 0 1 23 4 1 2 4 5 6 78 9 08 7 8 1 1 1 1 0 1 8 0 A 0 0 B 9 6 6 4 Compliance bintec elmeg 20 RM7000 ...

Страница 25: ...e use an appropriate waste disposal facility Das auf dem Gerät befindliche Symbol mit dem durchgekreuzten Müllcontainer bedeutet dass das Gerät am Ende der Nutzungsdauer bei den hierfür vorgese henen Entsorgungsstellen getrennt vom normalen Hausmüll zu entsorgen ist El símbolo del contenedor con la cruz que se encuentra en el aparato significa que cuando el equipo haya llegado al final de su vida ...

Страница 26: ...11 65 EU RoHS of the European Parliament and of the Council German DE Deutsch Hiermit erklärt bintec elmeg die Übereinstimmung des Geräts RM7000 mit Richtlinie 2014 30 EU EMC Richtlinie 2014 35 EU LVD Richtlinie 2009 125 EG ErP Richtlinie 2011 65 EU RoHS des Europäischen Parlaments Spanish ES Español Por la presente bintec elmeg declara que el tipo de equipo de telecomunica ciones RM7000 es confor...

Страница 27: ...pplication of CE marking in accordance with the 2014 30 EU EMC and the 2014 35 EU Low Voltage Directives IEC EN 60950 1 IEC EN 60825 1 and IEC EN 60825 2 European standard FCC 21 CFR Chapter 1 Subchapter J in accordance with FDA and CDRH re quirements UL and or CSA registered component for North America 47 CFR Part 15 Class A bintec elmeg 4 Compliance RM7000 23 ...

Страница 28: ...e router Please check the bintec website http www bintec elmeg com for a list of suppor ted 3G USB modems Check that the appropriate license is available for use A 2 Updating the software The RM7000 router can be updated to new versions Please contact your distributor for further details on new re leases There are several ways to update a bintec router For further information please see manual bin...

Страница 29: ...rough the the RJ45 connector cable supplied with the device and an RJ45 female DB9 female adaptor also provided Fig 31 Connecting for Configuration A 4 Connectors A 4 1 LAN connector switch RJ45 LAN RJ45 PIN FE Signals GE Signals 1 2 3 4 5 6 7 8 BI DA PoE BI DA PoE BI DB PoE BI DB PoE BI DA BI DA BI DB BI DC BI DC BI DB BI DD BI DD bintec elmeg Technical Information RM7000 25 ...

Страница 30: ...als 1 2 3 4 5 6 7 8 BI DA BI DA BI DB BI DB BI DA BI DA BI DB BI DC BI DC BI DB BI DD BI DD A 4 3 WAN SFP connector SFP Standard SFP connector A 4 4 USB connector USB Type A PIN USB 1 2 3 4 Shell VCC DATA DATA GND Shield Technical Information bintec elmeg 26 RM7000 ...

Страница 31: ...ale QorIQ MEMORY 1 Gbyte in SDRAM STORAGE UNIT FLASH Memory 32 Mbytes A 5 2 LAN interface PROTOCOLS Ethernet 802 3 PORTS 8 port switch managed with MDI MDX auto detection SPEED 10 100 1000 Mbps Base T CONNECTOR RJ45 female A 5 3 WAN Base T interface STANDARDS Ethernet 802 3 SPEED 10 100 1000 Mbps Base T CONNECTOR RJ45 female bintec elmeg Technical Information RM7000 27 ...

Страница 32: ...ce complies with the USB 2 0 480 Mbps standard the end speed de pends on the 3G USB modem used CONNECTOR USB Type A A 5 6 Configuration interface LOCAL TERMINAL RS 232 9600 8 N 1 without flow control CONNECTOR RJ45 female on the device front panel A 5 7 Power supply INPUT VOLTAGE 100 240 V AC INPUT CURRENT 1 8 A INPUT FREQUENCY 50 60 Hz MAXIMUM POWER 60 W A 5 8 Dimensions and weight TYPE Desktop c...

Страница 33: ...A 5 9 Environmental specifications TEMPERATURE OPERATING NORMALLY 0 ºC to 40 ºC STORED 25 ºC to 70 ºC RELATIVE HUMIDITY On 5 to 90 bintec elmeg Technical Information RM7000 29 ...

Отзывы: