Rotary Level Indicator

OPERATING INSTRUCTIONS

PLEASE READ CAREFULLY

BinMaster: Division of Garner Industries

925-0268 Rev C

1020

www.

.com

[email protected]

1.800.561.8187

Содержание MAXIMA+ Series

Страница 1: ...MAXIMA Series Rotary Level Indicator OPERATING INSTRUCTIONS PLEASE READ CAREFULLY BinMaster Division of Garner Industries 925 0268 Rev C 1020 www com information itm com 1 800 561 8187 ...

Страница 2: ...Location and Mounting 5 2 2 Input Power and Field Wiring 6 2 3 Grounding 7 3 0 RELAYS 7 3 1 DPDT Relay 7 3 2 Fail Safe High 7 3 3 Fail Safe Low 8 3 4 STATUS Relay 8 4 0 TIME DELAY 9 4 1 Changing Time Delay 9 5 0 EXTERNAL LED 10 6 0 WARRANTY AND CUSTOMER SERVICE 10 7 0 DISPOSAL 10 EUROPEAN DECLARATION OF CONFORMITY 11 www com information itm com 1 800 561 8187 ...

Страница 3: ...DELS Internally protected no external fusing required Ambient Temperature Electronics 40 F to 158 F 40 C to 70 C Enclosure Type 4X 5 9 12 Hazardous locations Class II Groups E F G DPDT Relay Output 10 Amps 250 VAC Fail Safe Switch selectable High or Low level modes Status Indicator Relay SPDT 10 A 250 VAC optional DC Solid State Relay 1 A 42 VDC optional AC Solid State Relay 1 A 250 VAC Time Delay...

Страница 4: ... contact ratings as called out on the nameplate and in the installation manual Ensure that the enclosure cover is in place and secured tightly during normal operation If this product is used in a manner not specified by the manufacturer the safety protection could be compromised Safety Terms and Symbols WARNING Warning statements identify conditions or practices that could result in injury or loss...

Страница 5: ...ting again to indicate an uncovered condition 2 0 INSTALLATION 2 1 Location and Mounting TOP MOUNT 1 Locate and cut hole in top of bin to fit outside diameter of 1 1 4 pipe coupling 1 950 2 Position coupling halfway into bin and weld 3 Turn unit so conduit opening is in desired location 4 Add 1 4 extension pipe to desired length with standard 1 4 coupling on bottom end 5 Cut 1 1 4 support pipe app...

Страница 6: ...the maximum voltage and current as per equipment ratings and has a temperature rating of at least 70 C For relay outputs use wire that is sized and rated for the maximum voltage and current as per application up to 250 VAC 10A Installation shall be done by qualified personnel Caution Use supply wires suitable for 25 C above surrounding ambient Attention Utiliser des fils D Alimentation qui convien...

Страница 7: ...be connected to different phases only for voltages up to 125 VAC For voltages above 125 VAC the relays shall be connected to the same phase circuit only 3 1 DPDT Relay The DPDT relay utilizes a Fail Safe selection jumper F S There are two positions for this jumper High H and Low L A Fail Safe condition means that the DPDT relay contact positions are set up so that in the event of a fault condition...

Страница 8: ... jumper at the top of the circuit board see Figure 10 In the NORMAL NRM position the Status Relay is energized when the MAXIMA is oper ating correctly In this mode the shaft rotation is monitored If the shaft is not rotating then the covered switch is monitored to see if there is a covered condition If the shaft is not rotating and the covered switch is not indicating covers then the Maxima will g...

Страница 9: ...hat condition By default the time delay is set to 5 seconds for both switches This time delay can be changed by using the SETUP push button switch on the circuit board Refer to Figure 10 The Delay Time can be set for each switch independently or for both together if the same delay time is desired for both delay on covered and delay on uncovered The maximum time delay that can be programmed is 25 s...

Страница 10: ...rm the equipment purchase Failure to do so may void the warranty 2 The manufacturer will repair or replace any part of this equipment found to be defective provided such part is delivered prepaid to the factory Manufacturer s obligation is limited to the cost of material and labor to repair or replace and does not include transportation expenses 3 This warranty shall not apply to any product that ...

Страница 11: ...s described in this manual will provide a safe and reliable point level control device for bulk solid materials Low Voltage Directive 73 23 EEC Standard IEC 61010 1 2001 Product Rotary point level control device Models MAXIMA AC Model 24 VAC 115 VAC 230 VAC DC Models 12 VDC and 24 VDC All test reports and documentation are held and can be obtained from BinMaster Manufacturing Location Lincoln Nebr...

Страница 12: ...onments where it is possible for moisture or moist air to enter the enclosure through the electrical conduit the conduit opening should be sealed with a duct seal compound or putty appropriate for the purpose Always mount unit with conduit opening down Mounting Instructions www com information itm com 1 800 561 8187 ...