Binks MAG AA Скачать руководство пользователя страница 8

MaG aa aUtoMatic ManifoLd MoUnted aiR aSSiSted aiRLeSS SPRaY GUn

HoW to oRdeR tHe MaG aa  
aUtoMatic SPRaY GUn WitH ManifoLd

4001-0000-0 

MAG AA Automatic Spray Gun WITH MANIFOLD, less Air Cap and Spray Tip

4001-0000-2 

MAG AA Automatic Spray Gun WITH MANIFOLD & AA2 AIR CAP, less Spray Tip

4001-0000-4 

MAG AA Automatic Spray Gun WITH MANIFOLD & AA4 AIR CAP, less Spray Tip

HoW to oRdeR tHe MaG aa  
aUtoMatic SPRaY GUn WitHoUt ManifoLd

4002-0000-0 

MAG AA Automatic Spray Gun WITHOUT MANIFOLD, less Air Cap and Spray Tip

4002-0000-2 

MAG AA Automatic Spray Gun WITHOUT MANIFOLD, WITH AA2 AIR CAP,  
less Spray Tip

4002-0000-4 

MAG AA Automatic Spray Gun WITHOUT MANIFOLD, WITH AA4 AIR CAP,  
less Spray Tip

Spray tips must be ordered separately. Use the spray tip selection chart to 
determine orifice size and fan size required.

SPRaY tiP SeLection cHaRtS

6/10   © 2010 

 Inc.   All rights reserved.   Printed in U.S.A.

 industrial finishing

Binks has authorized distributors throughout the world. For technical 

assistance or the distributor nearest you, see listing below.

U.S./canada technical Service office: 

195 Internationale Blvd., Glendale Heights, IL 60139 

Toll-Free Telephone: 1-888-992-4657 (U.S.A. and Canada only) 

Toll-Free Fax: 1-888-246-5732

Binks Worldwide Sales and Service Listing: www.binks.com

WaRRantY

This product is covered by Binks’ 1 Year Limited Warranty.

77-2797R-6 Revisions:

 (P8) Replaced Spray Tip Selection Charts.

aiRLeSS SPRaY tiP – fLUid fLoW Rate*

  oRifice Size 

500 PSi 

1000 PSi 

1500 PSi 

  (incHeS) 

oz./Min. 

oz./Min. 

oz./Min

VERY THIN – Wash Primers, Dyes, Stains, Solvents
 

.009 

5.1 

7.1 

8.2

 

.011 

8.1 

11.5 

13.6

 

.013 

11.7 

17 

19.9

THIN – Sealers, Lacquers, Primers, Ink, Zinc Chromate
 

.015 

16.5 

23.3 

27.8

 

.017 

21 

30.2 

35.9

MEDIUM – Lacquers, Synthetics, Enamels, Varnishes
 

.019 

26.6 

37.8 

45.6

 

.021 

32.8 

45.8 

56.8

 

.024 

39.7 

56.1 

68.7

 

.027 

50.4 

71.2 

87.2

Flow rate of fluid materials through spray tip, oz./min. 

*  Based on 1000 PSI with water. Actual results may vary, depending  

on material viscosity.

RePaiR & cLeaninG KitS

PaRt no.  deScRiPtion

20-6750-K10  Kit of 10 O-rings (for AA4 air cap)
54-4994 

 Cleaning Kit: includes one standard stiff nylon 

pipe cleaning brush, full-size nylon brush, tip 

cleaner, and Binks Gunners Mate Lubricant

54-5303 

Standard Performance Seal Kit

54-5304 

Piston Collet Repair Kit

54-5307 

High Performance Seal Kit

54-5305 

 Optional Mount “K” Kit: includes adapter  

plate assembly

54-5306 

 CEFLA Fluid Fitting Kit

54-5315 

Piston Assembly AA Gun

54-5399 

Single Bolt CEFLA Adapter Kit

fLUid SeatS

PaRt no.  deScRiPtion

54-4926 

 Standard UHMW Fluid Seat

54-4960 

 Optional Tungsten Carbide Fluid Seat

fLUid fiLteR

PaRt no.  deScRiPtion

54-1835 

 100 Mesh Filter

aiR caPS

PaRt no.        deScRiPtion

AA-2 - 54-4980   Thin to Medium Materials
AA-4 - 54-4978   Medium to Heavy Materials

acceSSoRieS

PaRt no.  deScRiPtion

54-4997 

HVLP Test Gauge AA2

54-5022 

HVLP Test Gauge AA4

54-380 

Gun Mounting Bracket

54-3691 

Gun Covers (Package of 20)

tiP 

aSSeMBLY 

PaRt no.

oRifice

fan 

WidtH 

(in.)

GPM 

caPacitY 

@500 PSi 

WateR

114-00702

.007

2

.028

114-00704

.007

4

.028

114-00706

.007

6

.028

114-00707

.007

8

.028

114-00902

.009

2

.039

114-00904

.009

4

.039

114-00906

.009

6

.039

114-00908

.009

8

.039

114-00910

.009

10

.039

114-00912

.009

12

.039

114-01104

.011

4

.060

114-01106

.011

6

.060

114-01108

.011

8

.060

114-01110

.011

10

.060

114-01112

.011

12

.060

114-01114

.011

14

.060

114-01304

.013

4

.090

114-01306

.013

6

.090

114-01308

.013

8

.090

114-01310

.013

10

.090

114-01312

.013

12

.090

114-01314

.013

14

.090

114-01316

.013

16

.090

114-01506

.015

6

.120

114-01508

.015

8

.120

114-01510

.015

10

.120

114-01512

.015

12

.120

114-01514

.015

14

.120

114-01516

.015

16

.120

114-01518

.015

18

.120

Fan width based on 1000 PSI with water. Actual results may vary, depending 
on material viscosity.

tiP 

aSSeMBLY 

PaRt no.

oRifice

fan 

WidtH 

(in.)

GPM 

caPacitY 

@500 PSi 

WateR

114-01706

.017

6

.160

114-01708

.017

8

.160

114-01710

.017

10

.160

114-01712

.017

12

.160

114-01714

.017

14

.160

114-01716

.017

16

.160

114-01718

.017

18

.160

114-01816

.018

16

.180

114-01906

.019

6

.190

114-01908

.019

8

.190

114-01910

.019

10

.190

114-01912

.019

12

.190

114-01914

.019

14

.190

114-01916

.019

16

.190

114-01918

.019

18

.190

114-02110

.021

10

.240

114-02112

.021

12

.240

114-02114

.021

14

.240

114-02116

.021

16

.240

114-02118

.021

18

.240

114-02410

.024

10

.310

114-02412

.024

12

.310

114-02414

.024

14

.310

114-02416

.024

16

.310

114-02418

.024

18

.310

114-02710

.027

10

.385

114-02712

.027

12

.385

114-02714

.027

14

.385

114-02716

.027

16

.385

114-02718

.027

18

.385

Содержание MAG AA

Страница 1: ...cause injuries and some paints and solvents can be toxic or cause explosions and fires under certain conditions your safety and the safety of others depend on your reading the information on this Par...

Страница 2: ...s Improper grounding poor air ventilation open flames or sparks can cause a hazardous condition and result in fire or explosion and cause serious injury FIRE AND EXPLOSION HAZARD Ground the equipment...

Страница 3: ...he air cylinder fitting located on the manifold Controlling the material flow When fed from a pressure supply an increase in material pressure will increase the rate of flow Correct fluid tip size ens...

Страница 4: ...disappear 3 If increasing air pressure does not dissipate the tails the fluid tip may be worn and may need to be replaced Another sign of the need to replace a worn tip is a gradual decline in sprayin...

Страница 5: ...Place a standard screwdriver inside the cavity where the filter 30 is housed and dislodge it by lifting up with the screwdriver Remove filter and clean or replace as required Most of the time you can...

Страница 6: ...FITTING CYLINDER AIR SIDE PORT AIR FAN ADJUSTMENT 1 4 NPT F FAN AIR INLET 1 4 NPT F ATOMIZING AIR INLET 1 2 DIA HOLE FOR GUN MOUNTING ROD SET SCREW FOR ROD MOUNT OR SINGLE BOLT ADAPTER MOUNT 1 4 NPT...

Страница 7: ...54 5335 Air Fluid Inlet Manifold Assembly 1 27 54 5340 Filter Retainer Assembly 1 28 20 5921 O Ring 2 017 Teflon 1 29 20 6131 1 4 NPT Plug Hex Socket HD S S 2 30 54 1835 100 Mesh Filter Assembly 1 31...

Страница 8: ...ff nylon pipe cleaning brush full size nylon brush tip cleaner and Binks Gunners Mate Lubricant 54 5303 Standard Performance Seal Kit 54 5304 Piston Collet Repair Kit 54 5307 High Performance Seal Kit...

Отзывы: