background image

81883X

Page  2 of 12

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE 

STATIC SPARK

 

HAZARDOUS MATERIALS 

HAZARDOUS PRESSURE

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause personĆ

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the

pump model plate.

S

Be sure material hoses and other components are able to withĆ

stand fluid pressures developed by this pump. Check all hoses

for damage or wear. Be certain dispensing device is clean and

in proper working condition.

WARNING

 

STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

S

Sparks can ignite flammable material and vapors.

S

The  pumping  system  and  object  being  sprayed  must  be

grounded when it is pumping, flushing, recirculating or sprayĆ

ing flammable materials such as paints, solvents, lacquers,

etc. or used in a location where surrounding atmosphere is

conducive to spontaneous combustion. Ground the dispensĆ

ing valve or device, containers, hoses and any object to which

material is being pumped.

S

818831 Groundable Acetal pumps: Use the pump grounding

screw provided. Connect a 12 ga. (min.) wire (kit is included) to

a good earth ground source.

S

Secure  pump,  connections  and  all  contact  points  to  avoid

vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific

grounding requirements.

S

After grounding, periodically verify continuity of electrical path

to ground. Test with an ohmmeter from each component (e.g.,

hoses, pump, clamps, container, spray gun, etc.) to ground to

insure continuity. Ohmmeter should show 0.1 ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in

the material being dispensed if possible. (Avoid free streaming

of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

WARNING

 

Pump exhaust may contain contaminants. Can

cause severe injury. Pipe exhaust away from work area and perĆ

sonnel.

S

In the event of a diaphragm rupture, material can be forced out

of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping hazĆ

ardous or inflammable materials.

S

Use a grounded 3/8" minimum i.d. hose between the pump and

the muffler.

WARNING

 

HAZARDOUS PRESSURE. Can result in serious

injury  or  property  damage.  Do  not  service  or  clean  pump,

hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sysĆ

tem by opening dispensing valve or device and / or carefully

and slowly loosening and removing outlet hose or piping from

pump.

WARNING

 

HAZARDOUS MATERIALS. Can cause serious inĆ

jury or property damage. Do not attempt to return a pump to the

factory  or  service  center  that  contains  hazardous  material.

Safe handling practices must comply with local and national

laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the

supplier for proper handling instructions.

CAUTION

 

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or reĆ

circulated. Chemical compatibility may change with temperaĆ

ture  and  concentration  of  the  chemical(s)  within  the

substances  being  pumped,  flushed  or  circulated.  Consult

Bink's representative for information on chemical compatibiliĆ

ty.

CAUTION

 

Maximum temperatures are based on mechaniĆ

cal  stress  only.  Certain  chemicals  will  significantly  reduce

maximum safe operating temperature. Consult Bink's repreĆ

sentative for information on chemical compatibility. Refer to

PUMP DATA on page 1 of this manual.

CAUTION

 

Be certain all operators of this equipment have

been trained for safe working practices, understand it's limitaĆ

tions, and wear safety goggles / equipment when required.

CAUTION

 

Do not use the pump for the structural support of

the  piping  system.  Be  certain  the  system  components  are

properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible connecĆ

tions (such as hose), not rigid piped, and should be compatible

with the substance being pumped.

CAUTION

 

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periods

of time.

S

Disconnect air line from pump when system sits idle for long

periods of time.

CAUTION

 

Use only genuine Bink's replacement parts to asĆ

sure compatible pressure rating and longest service life.

NOTICE

 

Install  the  pump  in  the  vertical  position.  The

pump may not prime properly if the balls do not check by gravĆ

ity upon startĆup.

NOTICE

 

ReĆtorque all fasteners before operation. Creep

of housing and gasket materials may cause fasteners to loosĆ

en. ReĆtorque all fasteners to insure against fluid or air leakage.

WARNING

CAUTION

NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or

substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product

or property damage.

= Important installation, operation or 

maintenance information.

Содержание 818830

Страница 1: ...imum Particle Size 3 32 dia 2 4 mm Maximum Temperature Limits based on the materials of the following items Fluid Caps Manifolds Seats Diaphragms Seals Balls E P R 60_ to 280_ F 51_ to 138_ C Groundab...

Страница 2: ...o not service or clean pump hoses or dispensing valve while the system is pressurized S Disconnect air supply line and relieve pressure from the sys tem by opening dispensing valve or device and or ca...

Страница 3: ...tible with the Nitrile O rings in the air motor section of the pump OPERATING INSTRUCTIONS S Always flush the pump with a solvent compatible with the material being pumped if the material being pumped...

Страница 4: ...035 SS L 2 O Ring 3 32 x 5 8 o d 1 B 3 O Ring 1 16 x 9 16 o d models 818834 818838 2 T 5 Diaphragm Washer 2 o d 2 873403 GFN 6 Diaphragm Washer 2 o d 2 873287 SS L 7 Diaphragm 2 T L 8 Diaphragm models...

Страница 5: ...05 in lbs 10 7 11 9 Nm 26 Bolts 50 60 in lbs 5 6 6 8 Nm 62 Fluid cap nuts 50 60 in lbs 5 6 6 8 Nm alternately and evenly then re torque after initial run in Apply pipe sealant to threads Apply Key Lub...

Страница 6: ...o Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl 1 Connecting Rod 1 873035 SS 873035 SS 873035 SS 873035 SS 873035 SS s L 2 O Ring 3 32 x 5 8 o d 1 B B B B B 3 O Ring 1 16 x 9 16 o d 2 T 5 Diaphr...

Страница 7: ...ragm nut 95 105 in lbs 10 7 11 9 Nm 29 62 Fluid caps Manifold nuts 50 60 in lbs 5 6 6 8 Nm alternately and evenly then re torque after initial run in 63 Plugs 25 in lbs 2 8 Nm maximum Apply Keylube to...

Страница 8: ...Carbon Steel SS Stainless Steel CK Ceramic SY Syn Seal DIAPHRAGM PUMP SERVICE GENERAL SERVICE NOTES S Inspect and replace old parts with new parts as necessary Look for deep scratches on metallic sur...

Страница 9: ...rs and 142 washers on 118 pilot rod 2 Insert the stack into the 101 body Sleeve 103 may be used to as sist pressing stack into body 3 Install 103 sleeve and 102 O rings into 101 body 4 Install 143 pla...

Страница 10: ...utlet hose S For the pump to prime itself it must be mounted in the vertical posi tion so that the balls will check by gravity S Check for pump cavitation suction pipe should be 1 2 minimum or larger...

Страница 11: ...mm Dimensions shown are for reference only they are shown in inches and millimeters mm 10 1 16 256 mm 5 16 Slot 8 mm 7 1 2 191 mm 2 51 mm 6 1 8 156 mm Material Outlet 1 2 14 N P T F 1 Air Inlet 1 4 18...

Страница 12: ...PN 876012 81883X Page 12 of 12...

Отзывы: