Use when fluid pressure in tank is regulated by some other, separate, method of control.

ITEM 

NO.

PART  

NO.

DESCRIPTION

QTY.

1

• —

ADAPTER, 1/4 NPT(F) X 1/4 NPS 

(SW)

1

2

• —

STREET TEE

1

3

83-1290 GAUGE, 150 PSI

1

4

VA-542 BALL VALVE

1

•Purchase locally

 

 

 
 

AIR IN

QMS-4003 NO REGULATION KIT

85-469 CONVERSION TO DOUBLE REGULATOR ASSEMBLY KIT

 Convert standard single regulator or extra-sensitive air control to a double regulator air control.

ITEM 

NO.

PART  

NO.

DESCRIPTION

QTY.

6

• —

1/4 NPT PLUG 

(SUPPLIED W/ REGULATOR)

1

7

83-4233 D.M. NIPPLE 1/4 x 3/8

1

8

HAR-507 AIR REGULATOR

1

9

83-1355 GAUGE – 100 PSI

1

•Purchase locally

EXISTING 
REGULATOR 

AIR IN

1

2

3

4

1

5

ITEM 

NO.

PART  

NO.

DESCRIPTION

QTY.

1

ADAPTER, 3/4 NPT-NPS UNIVERSAL

2

2

ELBOW, 3/4 NPT (F)

1

3

PIPE NIPPLE

1

4

BALL VALVE, 3/4 NPT FULL PORT

1

5

183-3005 LEG KIT

3

BOTTOM OUTLET KIT WITH LEGS

Allows conversion of tank from standard top outlet to bottom 
outlet. All bottom outlet wetted parts are stainless steel. 

183-3001

 for 5/10/15 gallon tanks with ¾” bottom outlets. 

Includes three 183-3005 Leg Kits.

Legs can be oriented either inward or outward to provide flexibility 
in mounting.

Outward orientation

Inward orientation

BOTTOM OUTLET KIT

EN

77-3134-R1.0  (9/2017)

10 / 12

www.carlisleft.com

Содержание 183G-200

Страница 1: ...0 Extra Sensitive w gun regulation None 183S 1043 Extra Sensitive w gun regulation Gear reduced Heavy duty STAINLESS STEEL 15 GALLON MODELS Tank Model Regulation Agitation 183S 1500 None None 183S 151...

Страница 2: ...n valve at anyone or any part of the body b Never put hand or fingers over the spray tip c Never attempt to stop or deflect fluid leaks with your hand body glove or rag d Always have the tip guard on...

Страница 3: ...olvents will also corrode the galvanized tank coating 1 Read the label or data sheet for the material Do not use materials containing these solvents with galvanized pressure tanks Stainless steel tank...

Страница 4: ...id and air pressures is not required Also Used where atomization air can be taken from filter regulator air lines Standard Double Regulation Precision control for use with materials that are best appl...

Страница 5: ...oosen spray gun air cap retaining ring about three turns 6 Turn on air supply 7 Cup cloth over air cap on the gun and pull trigger This will force material back through the hose into the tank 8 Empty...

Страница 6: ...GALLON GALVANIZED TANK ASSEMBLIES For bottom outlet conversion remove and discard plug Refer to 77 3138 for more information 39 The 5 10 gallon tanks come standard with one Agitator Paddle Kit 26 The...

Страница 7: ...ID TUBE 1 22 QMS 12 1 FLUID TUBE 1 23 QMS 6 AGITATOR SHAFT 1 23 QMS 7 AGITATOR SHAFT 1 23 QMS 8 AGITATOR SHAFT 1 24 AGITATOR PADDLE 1 1 2 25 SOC HEAD CAP SCREW 5 16 18 X 1 1 4 S S 1 2 3 26 QMS 444 AGI...

Страница 8: ...service parts DOUBLE REGULATOR AIR CONTROL Control tank pressure and spray gun atomization pressure 85 472 for non agitated tanks 85 473 for agitated tanks Items with an asterisk are for use with an...

Страница 9: ...arts EXTRA SENSITIVE REGULATOR AIR CONTROL DOUBLE REGULATOR Provides extremely high precision control of tank pressure plus standard regulation for a spray gun Includes 40 PSI Safety Valve Not shown 8...

Страница 10: ...NIPPLE 1 4 x 3 8 1 8 HAR 507 AIR REGULATOR 1 9 83 1355 GAUGE 100 PSI 1 Purchase locally 9 7 8 6 EXISTING REGULATOR AIR IN 1 2 3 4 1 5 ITEM NO PART NO DESCRIPTION QTY 1 ADAPTER 3 4 NPT NPS UNIVERSAL 2...

Страница 11: ...The liner is made of tough durable leakproof poly ethylene and can be used with all compatible materials PTL 408 K20 Kit of 20 tank liners 9 8 gal PTL 412 K8 Kit of 8 tank liners 11 8 gal PTL 415 K10...

Страница 12: ...SA Canada info carlisleft com Tel 1 888 992 4657 Fax 1 888 246 5732 United Kingdom info carlisleft eu Tel 44 0 1202 571 111 Fax 44 0 1202 573 488 China mkt carlisleft com cn Tel 8621 3373 0108 Fax 862...

Страница 13: ...3S 1033 Extra sensible nica Engranaje reducido reforzado 183S 1040 Extra sensible c regulaci n de pistola Ninguna 183S 1043 Extra sensible c regulaci n de pistola Engranaje reducido reforzado MODELOS...

Страница 14: ...sona ni hacia ninguna parte del cuerpo b Nunca ponga la mano ni los dedos sobre la punta pulverizadora c Nunca trate de detener ni desviar los escapes de fluido con la mano el cuerpo guantes o trapos...

Страница 15: ...hoja de informaci n del material No use materiales que contengan estos solventes con tanques a presi n galvanizados Se pueden usar modelos de tanques de acero inoxidable con solventes halogenados 2 C...

Страница 16: ...n tanto de fluido como de la presi n de aire Tambi n usado donde el aire de atomizaci n se pueda tomar de las l neas de aire del filtro regulador Regulaci n doble est ndar Control de precisi n para us...

Страница 17: ...6 Active el suministro de aire 7 Coloque un pa o sobre la tapa de aire en la pistola y accione el disparador Esto har que el material retorne a trav s de la manguera hacia el tanque 8 Vac e y limpie...

Страница 18: ...ASELINA GRASA PG 25 24 24 25 27 25 22 23 18 17 16 15 11 13 12 19 9 8 7 6 2 3 4 39 1 38 37 36 33 32 31 30 35 29 21 20 34 26 28 10 5 PG PG 26 14 77 3133 PAGE 6 5 10 15 GALLON GALVANIZED TANK ASSEMBLIES...

Страница 19: ...3 QMS 6 EJE DEL AGITADOR 1 23 QMS 7 EJE DEL AGITADOR 1 23 QMS 8 EJE DEL AGITADOR 1 24 PALETA DEL AGITADOR 1 1 2 25 TORNILLO DE CABEZA ENCASTRADA 5 16 18 X 1 1 4 AI 1 2 3 26 QMS 444 KIT DE PALETAS DEL...

Страница 20: ...NTROL DE AIRE CON REGULADOR DOBLE Presi n del tanque de control y presi n de atomizaci n de la pistola pulverizadora 85 472 para tanques sin agitaci n 85 473 para tanques con agitaci n Los art culos c...

Страница 21: ...IRE CON REGULADOR EXTRA SENSIBLE Y REGULADOR DOBLE Proporciona control de precisi n sumamente alta de la presi n del tanque adem s de regulaci n est ndar para una pistola pulverizadora Incluyev lvulad...

Страница 22: ...METRO 100 PSI 1 Se vende localmente 9 7 8 6 REGULADOR EXISTENTE DE AIRE EN 1 2 3 4 1 5 ART NO PIEZA NO DESCRIPCI N CANT 1 ADAPTADOR 3 4 NPT NPS UNIVERSAL 2 2 CODO 3 4 NPT F 1 3 BOQUILLA DE TUBO 1 4 V...

Страница 23: ...S DE 5 10 Y 15 GALONES Los filtros de malla Prospector son una forma econ mica de eliminar las materias for neas de la pintura manchas barnices y revestimientos VS 534 FILTRO DE FLUIDO Filtro de fluid...

Страница 24: ...e ventas y apoyo al cliente listados a continuaci n EE UU Canad info carlisleft com Tel fono 1 888 992 4657 Fax 1 888 246 5732 Reino Unido info carlisleft eu Tel fono 44 0 1202 571 111 Fax 44 0 1202 5...

Отзывы: