4
www.bindicator.com
WRL180213 Rev. A
IV. MECHANICAL INSTALLATION
WARNING: REMOVE POWER FROM THE UNIT BEFORE INSTALLING REMOVING OR MAKING
ADJUSTMENTS.
CAUTION: DO NOT ROUTE SERIAL CABLES IN THE SAME CONDUIT WITH AC POWER CABLES.
MOUNTING CONSIDERATIONS:
• Mounting hardware is not supplied by Bindicator.
• When mounting the enclosure ensure there is enough clearance to open the front door completely.
Removal, insertion, and wiring of the modular PCB is done through the front of the unit.
• Preferred direct line of sight between antennas (devices)
• Minimize metallic obstacles between devices
•
Should not be close to high voltage sources
WHEN SEALING CONDUIT CONNECTIONS, ONLY USE SIKAFLEx 1A POLYURETHANE SEALANT
OR DOW CORNING RTV 738 OR 739. OTHER SEALANTS MAY CONTAIN ACETIC ACID WHICH IS
HARMFUL TO SENSORS AND ELECTRONICS.
DRILLING HOLES IN THE ENCLOSURE
The standard fiberglass NEMA 4X rated enclosure has no openings through which to route cables or install the
conduit. Hole location is critical for proper conduit installation. Check clearances to ensure that the fittings and
wire routing will not interfere with the PCB or enclosure door.
DO NOT DRILL HOLES THROUGH THE TOP OF ENCLOSURE AS THIS MAY ALLOW MOISTURE
SEEPAGE, WHICH CAN DAMAGE THE ELECTRONICS AND VOID THE WARRANTY.
PREPARE THE ENCLOSURE FOR CONDUIT
1. Open door of the enclosure.
2. Remove all four (4) mounting screws that attach the board to the enclosure.
3. Remove entire board, and place in a safe location.
4. Make a separate hole for the AC cable, the serial and CAT 5 wiring. Holes
should be made in the front 2 inches of the bottom of the enclosure (Figure 1);
this allows for appropriate spacing for cables.
5. Clean enclosure of any debris, replace the board back into the enclosure, using
all four (4) mounting screws.
6. Determine desired location for mounting the unit.
Figure 1. Bottom View
Содержание InvisiLink
Страница 1: ...InvisiLink Wireless Radio Installation Operation Manual IOMWRL180213 Rev A...
Страница 2: ......
Страница 15: ...11 www bindicator com WRL180213 Rev A NOTES...