Binder FED 115 Скачать руководство пользователя страница 12

 

 

 

FED (E2) 12/2014 

page 12/55 

 
The drying and heating ovens FED do not dispose of any measures of explosion protection. 

 

 

DANGER 

Explosion hazard. 
Danger of death. 

  Do NOT introduce any substance into the heating oven which is combustible or 

explosive at working temperature. 

  NO explosive dust or air-solvent mixture in the inner chamber. 

Any solvent contained in the charging material must not be explosive or inflammable. I.e., irrespective of 

the solvent concentration in the steam room, NO explosive mixture with air must form. The temperature 

inside the chamber must lie below the flash point or below the sublimation point of the charging material. 

Familiarize yourself with the physical and chemical properties of the charging material, as well as the 

contained moisture constituent and its behavior with the addition of heat energy. 
Familiarize yourself with any potential health risks caused by the charging material, the contained 

moisture constituent or by reaction products that may arise during the temperature process. Take 

adequate measures to exclude such risks prior to putting the drying and heating ovens into operation. 

 

 

DANGER 

Electrical hazard. 
Danger of death. 

  The unit must NOT become wet during operation or maintenance. 

The drying and heating ovens were produced in accordance with the VDE regulations and were routinely 

tested in accordance to VDE 0411-1 (IEC 61010-1). 
During and shortly after operation, the temperature of the inner surfaces almost equals the set-point. 

 

 

CAUTION 

The inner chamber, the exhaust duct, the door window (option), the door gaskets, 

and the access ports will become hot during operation. 
Danger of burning. 

  Do NOT touch the inner surfaces, the exhaust duct, the door window, the access ports, 

the door gaskets, or the charging material during operation. 

 
 

1.6  Intended use 

The  drying and heating ovens FED  are suitable for drying and heat treatment of solid or pulverized 

charging material, as well as bulk material, using the supply of heat. The solvent content must not be 

explosive or flammable. A mixture of any component of the charging material with air must NOT be 

explosive. The operating temperature must lie below the flash point or below the sublimation point of the 

charging material. The drying and heating ovens FED can be used to dry e.g. glassware. 

Other applications are not approved. 
The drying and heating ovens FED are not classified as medical devices as defined by the Medical 

Device Directive 93/42/EEC. 

Do NOT use the unit for drying processes when large quantities of vapor would form and result in 

condensation. 

Содержание FED 115

Страница 1: ...215 9110 0215 FED 400 E2 9010 0216 9110 0216 FED 400 UL E2 9010 0217 9110 0217 FED 720 E2 9010 0218 9110 0218 FED 720 UL E2 9010 0219 9110 0219 BINDER GmbH Address Post office box 102 D 78502 Tuttling...

Страница 2: ...ve 2006 95 EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits Directive 2006 95 CE du Parlement Eu...

Страница 3: ...en DIN EN 61010 2 010 2004 Safety requirements for electrical equipment for measurement control and laboratory use Part 2 010 Particular requirements for laboratory equipment for the heating of materi...

Страница 4: ...FED E2 12 2014 page 4 55 Product registration...

Страница 5: ...plant optional 17 5 START UP 18 5 1 Turning on the unit 18 5 2 Heating operation display 18 5 3 Air change 19 6 CONTROLLER SETTING 19 6 1 Display entry of temperature and ventilation set points witho...

Страница 6: ...INDER GmbH 40 10 DISPOSAL 40 10 1 Disposal of the transport packing 40 10 2 Decommissioning 41 10 3 Disposal of the unit in the Federal Republic of Germany 41 10 4 Disposal of the unit in the member s...

Страница 7: ...observing the instructions in this operating manual are prerequisites for hazard free use and safety during operation and maintenance In no event shall BINDER be held liable for any damages direct or...

Страница 8: ...ximity 1 2 2 Safety alert symbol Use of the safety alert symbol indicates a risk of injury Observe all measures that are marked with the safety alert symbol in order to avoid death or injury 1 2 3 Pic...

Страница 9: ...the hazard mandatory action Observe all other notes and information not necessarily emphasized in the same way in order to avoid disruptions that could result in direct or indirect injury or property...

Страница 10: ...IP type of protection acc to EN 60529 Temp safety device DIN 12880 Temperature safety device acc to standard DIN 12880 Class 2 0 Class of temperature safety device Art No 9010 0212 Art no of the unit...

Страница 11: ...tallation location please observe the guideline BGI GUV I 850 0 on safe working in laboratories formerly BGR GUV R 120 or ZH 1 119 laboratory guidelines issued by the employers liability insurance ass...

Страница 12: ...ust NOT become wet during operation or maintenance The drying and heating ovens were produced in accordance with the VDE regulations and were routinely tested in accordance to VDE 0411 1 IEC 61010 1 D...

Страница 13: ...precision thanks to the direct and distributed air circulation into the interior The fan supports exact attainment and maintenance of the desired temperature accuracy The inner chamber the pre heating...

Страница 14: ...nsportation damage has occurred The final tests of the manufacturer may have caused traces of the racks on the inner surfaces This has no impact on the function and performance of the unit Please remo...

Страница 15: ...or Do NOT lift units size 400 and 720 by hand Lift unit size 53 and 115 at its four lower corners with the aid of 2 people unit size 240 with the aid of 4 people and place it on a transport pallet wit...

Страница 16: ...ated data are possible Permissible ambient humidity 70 r H max non condensing Installation height max 2000 m 6562 ft above sea level When placing several units of the same size side by side maintain a...

Страница 17: ...by the local electricity supply company and as well as the VDE directives for Germany We recommend the use of a residual current circuit breaker Pollution degree acc to IEC 61010 1 2 Over voltage cat...

Страница 18: ...Press until the display lights up The controller is now in normal display actual value display If the oven is operating time functions Continuous operation or Timer operation with the set time just ru...

Страница 19: ...ue display The actual temperature value example 22 C is displayed 1 Press button The display shows alternately SP and the previous temperature set point example 60 C 2 With the buttons enter a set poi...

Страница 20: ...ven is operating the controller is in normal display actual value display The actual temperature value example 22 C is displayed 1 Press button The display shows alternately SPr and the actual tempera...

Страница 21: ...There are two possible time functions Continuous operation The display shows alternately t1 time function and the time function Continuous operation t inf The heating is permanently active independen...

Страница 22: ...Timer operation Timer not programmed or run down Press button to return to normal display actual value display automatically after approx 30 sec 6 3 2 Continuous operation 1 Press the time management...

Страница 23: ...use of this time depends on the timer function selected in the user menu chap 6 4 4 4 Press button to return to normal display actual value display automatically after approx 30 seconds The actual te...

Страница 24: ...Timer function chap 6 4 4 Press button Setting the interface mode and if appropriate the printer interval chap 6 4 5 Figure 6 Press down button for approx 5 seconds Press button to return to normal d...

Страница 25: ...sed if required The use of temperature ramps may result in the heating up times being considerably slowed down The entry in C min or in F min meaning the nominal value gradient and limits the maximum...

Страница 26: ...from the previously entered set point to the new one SP The actual value follows the set point value About set point display during ramp operation see chap 6 2 6 4 3 Chamber addressing If several dry...

Страница 27: ...he set point After the defined time has expired the heating is turned off Delayed on setting 2 After the time set has passed the heating is turned on and remain in continuous operation 1 Press down bu...

Страница 28: ...er function 5 Press again button The display alternately shows PFCt and the actual setting of the interface mode 6 Set the desired interface mode with buttons Settings Modbus 0 printer 1 In case of te...

Страница 29: ...mal display press the time management button The controller displays the actual time function If necessary select the time function Timer operation chap 6 3 1 In the entry level enter the desired time...

Страница 30: ...again the safety device by pressing the reset button 7b and turn on the chamber as described Figure 7 Temperature safety device class 2 Function The safety device class 2 is functionally and electric...

Страница 31: ...the set point Function check Check the temperature safety device class 2 at appropriate intervals for its functionality It is recommended that the authorized operating personnel should perform such a...

Страница 32: ...hap 7 3 the buzzer sounds as an additional signal You can turn it off with switch 11 4 The optimum setting of the safety device is obtained by turning the control knob clockwise by approximately one s...

Страница 33: ...6 4 3 8 2 Data logger kit BINDER Data Logger Kits offer an independent long term measuring system for temperature They are equipped with a keyboard and a large LCD display alarm functions and a real t...

Страница 34: ...mpletely The delivered plug serves to avoid emerging of vapors or loss of introduced inert gas if any via the exhaust duct Due to special demands of heat resistance use the delivered plug only CAUTION...

Страница 35: ...can escape into the surrounding atmosphere Inert gases in high concentrations is hazardous to health They are colorless and almost odorless and therefore practically imperceptible Inhalation of inert...

Страница 36: ...emperature PIN 2 temperature Temperature range 0 C to 300 C A suitable DIN plug is enclosed Figure 9 Pin allocation of DIN socket for option analogue outputs 9 Maintenance cleaning and service 9 1 Mai...

Страница 37: ...er switch and disconnect the power plug Completely dry the appliance before turning it on again 9 2 1 Cleaning Disconnect the chamber from the power supply before cleaning Disconnect the power plug Th...

Страница 38: ...om the surfaces with a moistened towel Let the unit dry Soapsuds may contain chlorides and must therefore NOT be used for cleaning With every decontamination method always use adequate personal safety...

Страница 39: ...ntrols In case of impurity of the interior with biological or chemical hazardous material there are three possible procedures depending on the type of contamination and of the charging material 1 The...

Страница 40: ...clearly in the delivery documents For security reasons we cannot accept a unit delivery if it does not carry an authorization number Return address BINDER GmbH Abteilung Service G ns cker 16 78502 Tut...

Страница 41: ...nd electronic equipment WEEE and German national law for electrical and electronic equipment Elektro und Elektronikger tegesetz ElektroG WEEE marking crossed out wheeled bin with solid bar under A sig...

Страница 42: ...to directive 2002 96 EC of the European Parliament and of the Council on waste electrical and electronic equipment WEEE BINDER devices are classified as monitoring and control instruments category 9 o...

Страница 43: ...dispose of it as special waste according to national law Fill out the contamination clearance certificate chap 13 and enclose it with the unit WARNING Contamination of the device with toxic infectiou...

Страница 44: ...y mode Press down the ON OFF button 5 until the display lights up Unit without function Red alarm pilot lamp of safety device 7a is lit Safety device class 2 has turned off the chamber Let cool down t...

Страница 45: ...ume The technical data refers to the defined usable volume Do NOT place samples outside this usable volume Do NOT load this volume by more than half to enable sufficient airflow inside the chamber Do...

Страница 46: ...39 37 1000 39 37 Height mm inch 400 15 75 480 18 90 600 23 62 800 31 50 1200 47 24 Depth mm inch 330 12 99 400 15 75 500 19 69 500 19 69 600 23 62 Interior volume l cu ft 53 1 9 115 4 1 240 8 6 400 14...

Страница 47: ...70 3 40 5 00 Unit fuse 6 3 x 32 mm 250V super time lag TT A 16 16 16 16 20 external external 3 x internal 3 x internal 3 x internal Legend 1 without outer glass door 2 up to 98 of the set value All t...

Страница 48: ...stainless steel with 1 set rack lockings Reinforced inner chamber with 2 reinforced racks Rubber pads for safe stacking 4 pieces Temperature safety device class 3 1 acc to DIN 12880 Disconnectable au...

Страница 49: ...1 8012 0001 Unit fuse 5x20mm 250V 10A semi time lag M 5006 0013 5006 0013 5006 0013 Over current release category B 16 A 5006 0042 5006 0042 Description Art No Thermal cut off device class 1 5006 0037...

Страница 50: ...gt bevor das Ger t Bauteil eintrifft Eine weitere Kopie soll dem Ger t Bauteil beigef gt sein Ggf ist auch die Spedition zu informieren Incomplete information or non conformity with this procedure wil...

Страница 51: ...substances weder giftige noch sonstige gef hrliche Stoffe enth lt oder solche anhaften That eventually generated reaction products are non toxic and also do not represent a hazard auch evtl entstande...

Страница 52: ...n entsteht haften und BINDER gegen eventuell entstehende Schadenanspr che Dritter freistellen We are aware that in accordance with Article 823 of the German Civil Code BGB we are directly liable with...

Страница 53: ...any time Take notice of shipping laws and regulations Please fill Reason for return request Duplicate order Duplicate shipment Demo Page one completed by sales Power Plug Voltage 115V 230 V 208 V 240V...

Страница 54: ...______________________________________________________________ c ____________________________________________________________________________ 3 2 Safety measures required for handling the list under 3...

Страница 55: ...all damages that are a consequence of incomplete or incorrect information provided by us and that we will indemnify and hold harmless BINDER Inc from eventual damage claims by third parties Name _____...

Отзывы: