© 2012 Binary
B-320-1CAT-HDIR-W
Installation and Users Manual
pg.13
6. INSTALLATION
Note: Do Not connect power to the B-320-1CAT-HDIR-W until all other connections are made and
the unit is installed.
6.1. B-320-1CAT-HDIR-W Transmitter Installation
1. Run the cabling in the wall to the location for the B-320-1CAT-HDIR-W:
HD Link Cable:
ShieldedCat5e/Cat6
Remote Power (Optional):
(See above)
2. Mount the B-320-1CAT-HDIR-W Transmitter in the desired location.
3. Install the Remote Power supply (Optional). See 5.4 Optional Remote Power (2 Conductor).
4. Connect the HDMI out of a source component using an HDMI cable.
5. Connect the cables from the wall to the B-320-1CAT-HDIR-W transmitter.
6. Connect the 5V DC 2A Power Supply to the Latch-Locking Power Jack
7. Select the desired EDID setting using the EDID Mode Selector dial. See 6.3 EDID Configuration.
Note:
If an EDID was learned into the transmitter, DO NOT move the dial away from 7 as the
EDID will be lost.
8. Install the B-320-1CAT-HDIR-W receiver following the steps outlined below.
6.2. B-320-1CAT-HDIR-W Receiver Installation
1. Run the cabling in the wall from the head end:
HD Link Cable:
Shielded Cat5e/Cat6
Remote Power (Optional):
(See above)
2. Install the B-320-1CAT-HDIR-W transmitter following the steps outlined in section 6.1.
B-320-1CAT-HDIR-W Transmitter Installation.
3. Connect the cables from the wall to the B-320-1CAT-HDIR-W receiver.
4. Install the B-320-1CAT-HDIR-W into the junction box mounted in the wall.
5. Connect an IR Flasher and/or IR receiver being used.
6. Connect an HDMI cable from the B-320-1CAT-HDIR-W to the display.
7. Connect the 5V DC 2A Power Supply to the Latch-Locking Power Jack if remote power is
not being used.
8. Set the Distance Control rotary switch to 7 (Weakest).
9. Plug the local or remote power supply into an AC outlet.
10. Calibrate for distance. See 6.4 Distance Calibration for details.