Part No. 382513
382513_B_HI
6
Operation
Initial Set-Up Assembly
Refer to Figure A in the Packing Checklist section to identify parts in Initial Set-Up Assembly.
1.
UNFOLD
the upper handle (A, Figure A) and slide handle lock loops (B, Figure A) into place to secure the
upper handle to the lower.
2.
ATTACH
the tine lift cable (C, Figure A) to the tine lever (D, Figure A) in the center of the handle by inserting
the pin into it. Then attach the bail cable (E, Figure A) to the bail (F, Figure A). Check to make sure the cables
are functioning properly before operation and not binding.
3.
CHECK
engine oil level and fill to proper level. Also check oil in gear reduction reservoir and fill if necessary.
See engine owner’s manual for type and amount of oil to use.
4.
CONNECT
spark plug wire. Set the engine stop switch (G, Figure A) to the ON position.
STARTING THE ENGINE
See engine manufacturer’s instructions for type and amount of oil and gasoline used. Engine must be level
when checking and filling oil and gasoline.
ENGINE SPEED: Controlled by lever on the engine. Under normal conditions, operate at the minimum
throttle speed to accomplish your task.
ON/OFF: Set the on/off switch to ON
FUEL VALVE: Move fuel valve to “ON” position. (Honda: Located below the air cleaner on the engine.)
CHOKE: Engage the choke when starting a cold engine. (Honda: Located below the air cleaner on the
engine.)
THROTTLE: Move the throttle control lever on the engine to fast position. Pull starting rope to start engine.
If your unit fails to start, check trouble shooting section in operator’s manual and also see engine
manual.
Note: Honda engines are equipped with a low oil sensor to prevent engine damage. When it sens
-
es a low oil condition (i.e. unit is operating or sitting on a steep slope) the engine shuts down. The low oil
condition must be corrected before the engine can be restarted. See the engine owner’s manual for more
information.
AERATING OPERATION
Note: Never park this unit on a slope of any kind. Always keep tines in the up position when parking the unit.
TINES RAISING/LOWERING: The tines are raised or lowered into the ground by operating the tine en
-
gagement lever on the upper handle. Tine penetration is very dependent on surface preparation. READ the
entire operation section before aerating.
ENGAGE TINES: With the aerator in the work area, lower the tines by releasing the center lever on the
handle. When the lever is in the forward position, pull up on the bail to engage the tines.
AERATE: Push the machine with the tines engaged. NOTE: In cold temperatures engage the tines in the
up position for two minutes to warm the cam grease. For maximum tine penetration apply downward pres
-
sure on the handle.