BigBattery 48V KONG Скачать руководство пользователя страница 6

Discharge Overcurrent

Protection Range

Scenario 2 (Short Circuit):

Discharge Overcurrent

Protection Delay Range

600 - 1800

Milliseconds

Discharge Overcurrent

Protection Recovery

Condition

Reconnection delayed 120

seconds

Balance

Function

Minimum Cell Voltage to

Activate Cell Balancing

3.35

Volts (DC)

Voltage Difference to

Activate Cell Balancing

10

Millivolts

(DC)

Balancing Mode

Balance when charging

Balancing Current Range

100 - 260

Milliamps

Temperature

Protection

High Temperature

Protection Value when

Charging

65

(149)

°C

(°F)

High Temperature

Protection Release Value

when Charging

55

(131)

°C

(°F)

Low Temperature

Protection Value when

Charging

-2

(28.4)

°C

(°F)

Low Temperature

Protection Release Value

when Charging

3

(37.4)

°C

(°F)

High Temperature

Protection Value when

Discharging

75

(167)

°C

(°F)

High Temperature

Protection Release Value

when Discharging

65

(149)

°C

(°F)

Low Temperature

Protection Value when

Discharging

-20

(-4)

°C

(°F)

Low Temperature

Protection Release Value

when Discharging

-10

(14)

°C

(°F)

Resistance

Resistance in the

Discharge Circuit Range

5 - 10

Milliohms

Self-Power

Consumption

Operating Mode Range

(relay closed)

35 - 50

Microamps

Sleep Mode

0.5

Microamps

Sleep Conditions

No current, communication, or

prolonged protection states

Time to Sleep Mode

18 hours

5

Need Further Assistance?

Email us @

[email protected]

(OR) Call us @ # (818) 280-3091.

Содержание 48V KONG

Страница 1: ...w...

Страница 2: ...Specs 4 4 Warnings Precautions 6 5 Parts Components 7 5 1 Installation Safety Guidelines 7 5 2 Parts Components 7 5 3 Battery Installation 8 6 Battery Interface 9 6 1 Overview 9 6 2 BMS Codes 10 7 Re...

Страница 3: ...a larger power system Multiple layers of safety and battery protection High quality durable steel construction Utilizes standardized 175 amp connector for battery power source LED Smart Display BigBa...

Страница 4: ...att hours Kilowatt hours Operating Voltage Range 43 58 8 Volts DC Charging Voltage Range 55 6 58 0 Volts DC Max Charging Voltage 58 8 Volts DC WARNING Do NOT exceed max charging voltage Charging Curre...

Страница 5: ...Time 2000 Milliseconds Overcharge Protection Recovery Voltage 3 45 Volts DC Discharge Voltage Protection Low Voltage Protection Limit Range 2 5 2 7 Volts DC Low Voltage Protection Delay Time 2000 Mil...

Страница 6: ...e when Charging 55 131 C F Low Temperature Protection Value when Charging 2 28 4 C F Low Temperature Protection Release Value when Charging 3 37 4 C F High Temperature Protection Value when Dischargin...

Страница 7: ...es or any other heat source at a minimum distance of two feet away from the batteries Disconnect batteries immediately if during operation or charging they emit an unusual smell develop heat or behave...

Страница 8: ...ondition Use a screwdriver with a rubber coated handle When your battery has been charging and has come to maximum charge up to 58 8V max your battery may experience a slight voltage drop either immed...

Страница 9: ...onnector side of your 175 amp Ring Terminal connector cable to the receiving connector located on the battery unit Step 4 Place the battery in the space where you will store it and operate it Step 5 L...

Страница 10: ...6 Battery Interface 6 1 Overview 9 Need Further Assistance Email us Support BigBattery com OR Call us 818 280 3091...

Страница 11: ...Under temperature protection while charging DOCP Temperature Protection Over temperature protection while discharging DUTP Temperature Protection Under temperature protection while discharging COTP Cu...

Страница 12: ...arrantied component inspections initiated after the first 30 days of ownership Please note some battery returns may require special documentation and packaging and these instances will encounter extra...

Отзывы: