power off. The power on can be started after checking 

the correct connection of the line and the correct 

insertion of the drive, so as to prevent the wrong 

connection of the mainboard and drive from being burnt 

down and causing unnecessary losses;

 

 

BTT SKR MINI E3 V1.2 is a motherboard designed 

specifically for the Ender 3 printer. If the user 

wants to use another machine, please refer to the 

corresponding electrical parameters of Ender3 (such 

as hot bed power, heating rod power, etc.). The 

electrical parameters of other machines should never 

exceed the electrical parameters of Ender 3 machines. 

Otherwise our company will not compensate for any 

losses caused.

 

 

The E3 motherboard can support the LCD12864 

screen with the interface CR10_STOCKDISPLAY. 

If  you  encounter  other  problems  while  using,  please 

contact us, we will answer you scrupulous; if you have 

any good comments or suggestions for our products, pls 

feel free to inform us, we will carefully consider your 

comments  or  suggestions,  thank  you  for  choosing 

BIGTREETECH products, thank you! 

Содержание SKR MINI E3 V1.2

Страница 1: ...Shenzhen BIGTREE technology co LTD BIG TREE TECH BIGTREETECH SKR MINI E3 V1 2 User s manual ...

Страница 2: ...hold PCB board wiring is rigorous and beautiful and specializing in heat dissipation optimization Using a dedicated power chip to support 12 24V power input Accept 24V input reduce the hot bed current to 1 4 at the same power effectively solve the hot bed MOS tube heating problem Support 2 8 inch 3 5 inch color touch screen and original Ender3 printer LCD12864 screen Upgrade the firmware by SD car...

Страница 3: ...red light flashing shows the power supply is normal Red light D10 is status indicator light D10 flashes when user update the firmware and closes when the update is complete Green light D6 is hot bed HB status indicator light The hot bed is always bright when heated and extinguished when not heated Green light D4 is the E0 state indicator light of the heating rod D4 is always on when the heating ro...

Страница 4: ...Shenzhen BIGTREE technology co LTD BIG TREE TECH Interface Instruction 1 Motherboard Size Diagram 2 Motherboard Wiring Diagram ...

Страница 5: ...ed directly or can be changed according to your own needs The Firmware Acquisition Method of SKR Motherboard Obtain by Ask customer service or technical personnel Download at our Company Open source website https github com bigtreetech Motherboard firmware update method Choose the file suitable for your model in the downloaded firmware package to copy to SD Card Root directory Note File name canno...

Страница 6: ...orresponding electrical parameters of Ender3 such as hot bed power heating rod power etc The electrical parameters of other machines should never exceed the electrical parameters of Ender 3 machines Otherwise our company will not compensate for any losses caused The E3 motherboard can support the LCD12864 screen with the interface CR10_STOCKDISPLAY If you encounter other problems while using pleas...

Отзывы: