8. Install safety cable

WARNING: The safety cable is a crucial part of the fan and must be installed correctly. If you have any 
questions, call Customer Service.
CAUTION: Ensure there is enough slack in the safety cable to accommodate for the oscillating motion! 

Safety 

Cable

Gripple®

Column Mount 

Route one end of the safety cable through a Gripple

®

and then loop the cable around the column and 
back through the Gripple as shown. Route the cable 
through the second Gripple, around the fan yoke, and 
then back through the second Gripple as shown.

Note: Ensure the safety cable is secured to the 
column above the Column Mount brackets. Ensure 
the cable is secured to the fan yoke in the location 
shown below. If the cable is secured too high on the 
fan yoke, it may slide down the yoke during operation.

Pull the loose ends of the cable through the Gripples 
until the cable is drawn tightly around the column 
and fan yoke. Test the fan to ensure there will be 
enough slack in the safety cable to accommodate for 
the oscillating motion. Secure the loose ends of the 
cable with the two (2) wire rope clips and torque to  

4.5 ft·lb (6.1 N·m)

.

Yoke Mount 

Wrap the safety cable around the mounting structure, 
and then secure it with the shackle as shown below. 
Test the fan to ensure there will be enough slack in 
the safety cable to accommodate for the oscillating 
motion.

Shackle

Safety 

Cable

Wire 

Rope Clip

Содержание Yellow Jacket

Страница 1: ...INSTALLATION GUIDE Yellow Jacket Oscillator For help call 1 877 BIG FANS or visit www bigassfans com...

Страница 2: ...fan and control components Failure to follow all relevant codes and ordinances including but not limited to the National Electrical Code United States applicable national and local electrical codes an...

Страница 3: ...y installed WARNING Risk of fire electric shock or injury to persons during cleaning and user maintenance Disconnect the fan from the power supply before servicing CAUTION Do not bend the blades when...

Страница 4: ...illation optional 4 6 Remove Original Speed Control Cover 4 7 Install New Speed Control Cover and Complete Wiring 4 Wiring the Oscillator Wiring Diagram 5 Column Yoke Mount Parts and Hardware 6 Instal...

Страница 5: ...re required for installation contact Customer Service Note The illustrations below are not to scale Installation If you are installing the oscillator on a previously assembled fan with a portable base...

Страница 6: ...le and second pedestal After securing the wheels and first pedestal to the portable base attach the handle and second pedestal with the Pedestal Hardware Ensure the handle is on the same side as the w...

Страница 7: ...uld attach Ensure the oscillator motor is oriented Proceed to step 4 Lower Oscillator Hardware a 4 3 8 16 x 3 4 Hex Head Cap Screw b 4 3 8 Washer 4 Install fan yoke Secure the fan yoke to the oscillat...

Страница 8: ...Adjust angle of oscillation optional The oscillator arm is preset to oscillate a full 60 degrees however the angle of oscillation can be adjusted and set to 45 60 or 90 The innermost hole is 90 the mi...

Страница 9: ...s installation manual and with any additional requirements set forth by the National Electric Code NEC ANSI NFPA 70 2011 and all local codes Code compliance is ultimately YOUR responsibility 100k VIOL...

Страница 10: ...e complete Yellow Jacket Installation Guide for all other aspects of fan installation operation and safety information WARNING Do not prevent the oscillator from rotating when in operation WARNING The...

Страница 11: ...the speed knob from the original cover and set it aside Disconnect all wiring except the yellow purple and gray leads to the motor if present Remove the power cord and original cord grip connector fr...

Страница 12: ...ERVED 8 4 Install fan yoke Secure the fan yoke to the oscillator bracket Refer to the appropriate illustration for the mounting method used Lower Oscillator Hardware a 4 3 8 16 x 1 Hex Head Cap Screw...

Страница 13: ...the fan orientation and angle is set before routing the cord 4 Install the cord grip connector and power cord previously removed from original speed control in the open 1 2 connector hole on the junc...

Страница 14: ...d secure the speed control and oscillator switch cables to the new cord grip connectors on the remote speed control box 5 Verify the cord will have enough slack to accommodate oscillating motion Note...

Страница 15: ...cable is secured to the column above the Column Mount brackets Ensure the cable is secured to the fan yoke in the location shown below If the cable is secured too high on the fan yoke it may slide dow...

Страница 16: ...be in accordance with the requirements specified in this installation manual and with any additional requirements set forth by the National Electric Code NEC ANSI NFPA 70 2011 and all local codes Code...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...002582 Rev M 01 21 2020 2251 Innovation Drive Lexington KY 40511 1 877 BIG FANS WWW BIGASSFANS COM...

Отзывы: