8. Confirm Orientation
After securing the main fan unit to the lower yoke, allow the fan to hang
so that the extension tube is plumb to the ground. When it is properly
positioned, fully tighten all mounting hardware to 40 ft·lb (54.2 N·m).
9. Install Guy Wires
ATTENTION
Guy wires are intended to constrain the fan’s lateral movement and are only included with fans that have
extension tubes 4 ft (1.2 m) or longer. Depending on the conditions at the installation site, guy wires may
be needed for fans with shorter tubes to prevent lateral movement. If guy wires are needed and were not
included with your fan, contact Customer Service.
A. Attach locking carabiners to main fan unit
Attach the (4) locking carabiners to the guy wire brackets on the main fan unit. Securely tighten the carabiners.