Introduction (cont.)
Powerfoil
®
X2.0 specifications
Fan size
Motor size,
HP (kW)
Minimum required
supply circuit size
Nominal output
voltage, 3 Φ
1
Maximum full load
current
Max RPM
Airfoil length
Suggested
distance from
ceiling
2
8 ft
(2.4 m)
1.0
(0.75)
20 A @ 200–250 V, 1 Φ
10 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
4.4 A
3.2 A
1.5 A
1.3 A
113
RPM
37.5 in (1 m)
4 ft (1.2 m)
10 ft
(3 m)
1.0
(0.75)
20 A @ 200–250 V, 1 Φ
10 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
4.4 A
3.2 A
1.5 A
1.3 A
113
RPM
49.5 in (1.26 m)
4 ft (1.2 m)
12 ft
(3.6 m)
1.0
(0.75)
20 A @ 200–250 V, 1 Φ
10 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
4.4 A
3.2 A
1.5 A
1.3 A
106
RPM
61.5 in (1.56 m)
5 ft (1.5 m)
14 ft
(4.3 m)
1.5
(1.1)
30 A @ 200–250 V, 1 Φ
20 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
8.7 A
5.0 A
2.5 A
1.9 A
95
RPM
73.5 in (1.87 m)
5 ft (1.5 m)
16 ft
(4.9 m)
1.5
(1.1)
30 A @ 200–250 V, 1 Φ
20 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
8.7 A
5.0 A
2.5 A
1.9 A
95
RPM
85.5 in (2.17 m)
6 ft (1.8 m)
18 ft
(5.5 m)
1.5
(1.1)
30 A @ 200–250 V, 1 Φ
20 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
8.7 A
5.0 A
2.5 A
1.9 A
77
RPM
97.5 in (2.48 m)
6 ft (1.8 m)
20 ft
(6.1 m)
2.0
(1.5)
30 A @ 200–250 V, 1 Φ
20 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
10.7 A
6.2 A
3.0 A
2.3 A
70
RPM
109.5 in (2.78 m)
7 ft (2.1 m)
24 ft
(7.3 m)
2.0
(1.5)
30 A @ 200–250 V, 1 Φ
20 A @ 200–250 V, 3 Φ
10 A @ 400–480 V, 3 Φ
10 A @ 575–600 V, 3 Φ
240 V
240 V
480 V
600 V
10.7 A
6.2 A
3.0 A
2.3 A
55
RPM
133.5 in (3.39 m)
7 ft (2.1 m)
1.
Output voltage will not exceed Input voltage, with the exception of 120 V models. All controllers produce 3 Φ output power, regardless of input phase.
2. The distance of the fan from the ceiling should be measured from the top of the winglets to the ceiling.
CAUTION: Big Ass Fans requires that the Powerfoil X2.0 fan be supplied from one of the following types of transformers:
575–600 V models: 575/330 V Wye secondary (neutral not utilized)
400–480 V models: 480/277 V Wye secondary (neutral not utilized)
200–250 V models: 208/120 V Wye secondary (neutral not utilized)
240/120 V Delta secondary (Wild/High Phase B)
Integration into any other power distribution scheme may result in improper fan operation or premature hardware failure! See
page 26 for more information.
Содержание powerfoil x2.0
Страница 1: ...INSTALLATION GUIDE Powerfoil X2 0 Washdown For help call 1 877 BIG FANS or visit www bigassfans com...
Страница 6: ......
Страница 48: ......
Страница 56: ...Notes...
Страница 58: ......
Страница 66: ......
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ...002972 002972 2425 Merchant St Lexington KY 40511 1 877 BIG FANS WWW BIGASSFANS COM REV J...