BIG ASS FANS Powerfoil D Скачать руководство пользователя страница 6

5A. ELECTRICAL INSTALLATION (POWERFOIL X3.0)

Complete all steps in the fan Electrical Installation instructions included with the main fan unit in addition to the 
steps below. Do not apply power and test the VFD until all electrical installation steps are complete.

Install Static Tube Cable and Power Supply

Remove the VFD cover to access the VFD (six screws).

6-32 x 1/2" Flange 

Hex Head Screw

Power Supply

F1

F2 or F3

VFD Fusing

Brown

Blue

Green

PE/GND

VFD Plate

6-32 Serrated 

Flange Hex Nut

Note: Fire relay wiring should also be routed through provided grommet. 

Connect Power Supply

Reinstall the VFD cover when fi nished with all electrical connections.

Grommet

Содержание Powerfoil D

Страница 1: ...r attaching the Airfoil Restraint System straps to the fan hub Spare screws are included READ AND SAVE THESE INSTRUCTIONS TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOL...

Страница 2: ...d Nut 7 8 22 mm 7 8 22 mm FANS THAT ALREADY HAVE A STATIC TUBE If your fan already has a field installed removable static tube uninstall the static tube bracket and clamp Replace with the static tube...

Страница 3: ...OIL X3 0 ONLY If you received two couplers for your Powerfoil X3 0 fan install the SHORTER WHITE coupler if your fan already has a factory installed non removable static tube Use the TALLER BLACK coup...

Страница 4: ...4A HUB CONNECTIONS BRACKET AND CABLE POWERFOIL X3 0 5 16 12 x 1 2 Flange Hex Head Cap Screw Make sure the long screw on the bracket is inside the slot on the coupler 20 ft lb 27 1 N m...

Страница 5: ...4B HUB CONNECTIONS BRACKET AND CABLE POWERFOIL D 10 16 x 1 2 Flange Hex Head Cap Screw Make sure the long screw on the bracket is inside the slot on the coupler 4 ft lb 5 4 N m...

Страница 6: ...l installation steps are complete Install Static Tube Cable and Power Supply Remove the VFD cover to access the VFD six screws 6 32 x 1 2 Flange Hex Head Screw Power Supply F1 F2 or F3 VFD Fusing Brow...

Страница 7: ...stall Quick Connect Tabs on Power Wiring Terminal Block Remove the VFD housing cover to access the VFD six screws 5 16 8 mm socket Power Wires L1 L2 N L3 Terminals Black or Brown Red or Black White or...

Страница 8: ...ord grip reaches the top of the VFD housing Install the cord grip and nut in the back left hole on top of the housing The VFD s RJ45 connector may need to be removed to tighten the cord grip nut Ensur...

Страница 9: ...ed to be loosened to pull out additional slack Ensure all wiring is tucked inside the rectangular opening in the power supply mounting plate to avoid damage when reinstalling the VFD housing cover 1 2...

Страница 10: ...ring Harness End of Airfoil with Two Bolt Holes Female Wiring Harness Attach Winglets Orient ion generator brushes upward during assembly to prevent damage Airfoil Restraint System straps included onl...

Страница 11: ...il Restraint System straps and hardware included only with 20 24 ft 6 1 7 3 m fans or if ordered 7 ft lb 9 5 N m Hand Tighten 5 32 4 mm Correct Strap Orientation Install Airfoils Cables and Straps Mak...

Страница 12: ...stallation details 7 AIRFOIL INSTALLATION CONT Secure Airfoils Do not fully tighten the bolts until all retainers are attached Tighten the outer bolts first Powerfoil X3 0 shown Installation is the sa...

Страница 13: ...s Los tornillos son para fijar las correas de dicho sistema al centro del ventilador Se incluyen tornillos de repuesto LEA Y GUARDE ESTAS INSTRUCCIONES PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE EL CTR...

Страница 14: ...otor 7 8 22 mm 7 8 22 mm VENTILADORES QUE YA TIENEN UN TUBO EST TICO Si su ventilador ya tiene un tubo est tico instalado en el campo desmontable desinstale el tubo est tico el soporte y la abrazadera...

Страница 15: ...i recibi dos acoples para su ventilador Powerfoil X3 0 instale el acoplador M S CORTO DE COLOR BLANCO si su ventilador ya tiene un tubo est tico instalado de f brica no extra ble Utilice el acoplador...

Страница 16: ...4A SOPORTE Y CABLE DE CONEXIONES DEL CUBO POWERFOIL X3 0 Tornillo hexagonal flange de 5 16 12 x 1 2 Verifique que el tornillo largo del soporte est dentro de la ranura del acoplador 20 ft lb 27 1 N m...

Страница 17: ...4B SOPORTE Y CABLE DE CONEXIONES DEL CUBO POWERFOIL D Tornillo hexagonal flange de 10 16 x 1 2 Verifique que el tornillo largo del soporte est dentro de la ranura del acoplador 4 ft lb 5 4 N m...

Страница 18: ...n completos Instale el cable del tubo est tico y la fuente de alimentaci n Quite la cubierta del VFD para acceder al VFD seis tornillos Tornillo hexagonal flange de 6 32 x 1 2 Fuente de alimentaci n...

Страница 19: ...xi n r pida en el bloque de terminales de cableado de alimentaci n Retire la cubierta de la carcasa de VFD para acceder al VFD seis tornillos enchufe 5 16 8 mm Cables de alimentaci n L1 L2 N L3 Termin...

Страница 20: ...el agarre del cord n y la tuerca en el orificio posterior izquierdo de la parte superior de la carcasa Es posible que sea necesario retirar el conector RJ45 del VFD para apretar la tuerca de sujeci n...

Страница 21: ...se afloje m s Revise que todo el cableado est dentro de la abertura rectangular de la placa de montaje de la fuente de alimentaci n para evitar da os al reinstalar la cubierta de la carcasa del VFD A...

Страница 22: ...pas aerodin micas con dos orificios de perno Arn s de cableado hembra Coloque las aletas Oriente el generador de iones hacia arriba durante el montaje para evitar da os Las correas del sistema de rete...

Страница 23: ...odin micas y los accesorios est n incluidos con los ventiladores de 6 1 7 3 m 20 24 pies o si se solicitan en un pedido 7 ft lb 9 5 N m Ajuste con la mano 5 32 4 mm Orientaci n correcta de la correa I...

Страница 24: ...in mica No apriete completamente los pernos hasta que todos los retenedores est n colocados Apriete primero los pernos exteriores Se muestra el Powerfoil X3 0 La instalaci n es la misma para el Powerf...