4
TESTING ON KNOWN VOLTAGE
Testing with the Hand Held power supply on non-wired voltage
detectors only.
1.
Turn the meter in question on and follow the instruction for
preparing the unit for use. The power supply can test the appropriate
meters in any position listed on the chart on page 5.
2.
With the power supply in hand, depress and hold the power button.
If the light on the unit turns green, the battery voltage is good and
you can proceed to the next step. If the light is red, follow the
procedure on page 3 then repeat this step.
3.
While holding the power button down and holding the meter being
tested in hand, make contact with the metal disk on the end of the
power supply with the tip of the meter. The expected results are
shown on page 5.
NOTE: Depending on how the meter is held, the results could vary. The
results on page 5 are under normal conditions, holding the body of the
housing and not touching the probe or the quick change tool adapter. if
you are not sure of the results, please contact technical support for
assistance.
4.
Once test is complete, release the push button and return the power
supply to its normal storage location. The meter is now ready for use.
Содержание VD1000
Страница 1: ...1 Hand Held Power Supply Instruction Manual...
Страница 8: ...8...