background image

Press the vacuum "Manual On/Off" key and the pump

should run.  If not, check that the pump is plugged into the

back of the press and then have a qualified electrician re-

check the electrical hookup.  (If separate ground and neu-

tral lines are not installed, the pump may not operate even

though the display illuminates.)

After turning on the pump, the display should read a mini-

mum of 20" of Hg for: 3648H within 40 seconds, 4468H

within 1 minute and for the 5298H within 2 minutes.  If

there is any difficulty in drawing a proper vacuum, refer to

the Owner’s Adjustment Procedures section of Page 24 of

this manual.

Press the "Heat On" key and the press should begin to heat

up to 180ºF (+/- 2ºF) within 15-20 minutes.  If not, call

Hunt Technical Service at 888-240-6021.

The press is now ready for use.

Adjustment Procedures

Proper leveling of the press and adjustment of the hinges

and latch are necessary to consistently achieve proper

vacuum. Check the following owner adjustment procedures,

in the order listed, if any difficulty arises.

Leveling

If the press is not placed on a sturdy, flat, level surface,

proper operation cannot be guaranteed. Ensure press level-

ness by opening the press and placing a 2’ carpenter’s level

on the frame. Shim the floor stand legs so that the frame of

the press is level (both front-to-back and side-to-side). If not

on a floor stand, adjust the corner feet until the press is level.

Hinge Adjustment

After leveling the press, check the adjustment of the rear

hinges. These might shift during shipment, handling or 

rigorous use and are essential to proper alignment of the 

top to the base. To realign, follow these instructions:

1. Close and set temperature to 180ºF.

2. As your assistant holds open the lid, remove the clips

from the bottom of the gas springs (located around the

bottom socket head only) using the needle nose pliers.

This could possibly be done by hand. Bump first the 

bottom of the gas spring off the ball sockets from both

left and right sides of the machine. Then remove the top

by grasping the gas spring and tilt away from ball stud.

Spring will come off. The gas springs MUST be taken

completely off the machine. 

3. Loosen (do not remove) screws in the slotted holes of the

hinges, located on the back of the machine.

4. Once machine is fully heated, start the vacuum. Give unit

45 seconds to 1 minute to pull full vacuum. If no 

vacuum is achieved, walk around machine and put slight

pressure on lid in various sections until a full vacuum is

achieved.

5. Tighten set screws on hinges and replace gas springs.

If any further questions arise, contact your authorized

Bienfang

®

dealer or the Hunt Technical Service Department

at 1-888-240-6021.

INSTALLATION AND PREPARATION 

(CONTINUED)

5

Содержание Vacuum Press 3648H

Страница 1: ...Instruction Manual Provided By http www MyBinding com http www MyBindingBlog com BIENFANG 3648H 4468H 5298H VACUUM PRESS...

Страница 2: ...Bienfang Vacuum Press 3648H 4468H and 5298H Programmable Combination Vacuum Presses OWNERS MANUAL...

Страница 3: ...468H 3648H Catalog Number 2170 2160 2180 Floor Stand included 2165 2167 Working Area 48 x 96 x 1 44 x 68 x 1 36 x 48 x 1 Outside Dimensions 109 x 65 x 7 77 x 57 x 7 57 x 48 x 1 Net Weight 375 lbs 215...

Страница 4: ...fety and to prevent damage Contact your authorized Hunt dealer or Hunt Technical Service in the event the press needs service for parts not covered in this Owner s Manual IMPORTANT SAFEGUARDS The Bien...

Страница 5: ...se with Neutral on a 20 Amp circuit Actual line voltages between 208 230 VAC are acceptable The press power cord has a NEMA L14 20P twist lock plug which is UL listed for use in this application The 5...

Страница 6: ...that the frame of the press is level both front to back and side to side If not on a floor stand adjust the corner feet until the press is level Hinge Adjustment After leveling the press check the adj...

Страница 7: ...x 30 yds for 3648H 4468H Bienfang No 986 50 x 36 yds for 5298H Release Board a thin smooth board coated with silicone on both sides Lays flat to smooth out posters doesn t wrinkle or crease so it last...

Страница 8: ...urn off automatically because materials could be accidentally left inside the press with out pressure while they are still hot This could cause delaminating or excessive warping of the mounting board...

Страница 9: ...emem bered even after turning the press off To change the settings of an existing program press Program the keypad number and then the appropriate Set key numeric entry and Enter Press Enter a second...

Страница 10: ...key Watch the press temperature rise and when it reaches the bonding tempera ture allow an additional 1 4 minutes depending upon the size and type of material processing time Note the complete cycle...

Страница 11: ...materials or workmanship within the applicable warranty period will be repaired or at our option replaced without charge upon its return postpaid as outlined below The applicable warranty shall be one...

Страница 12: ...Inadequate time Reprocess longer High moisture level Reprocess longer Low uneven pressure See low vacuum Low high temperature Check specifications Checking the Pump and Fittings To check attachment of...

Страница 13: ...25 TS1105025 Breaker 2 Pole Domestic Intn TS1308041 TS1308041 TS1308061 Control Board Assembly Domestic TS2304093 TS2304093 TS2304093 International TS2304093 1 TS2304093 1 TS2304093 1 R bbon Cable Int...

Отзывы: