CA 1: 2.5L MS
ENG INSTRUCTIONS FOR USE
Other languages available onwww.bienair.com/ifu
REF
2100337-0001/2019.
11
Страница 1: ...CA 1 2 5L MS ENG INSTRUCTIONS FOR USE Other languages available on www bienair com ifu REF 2100337 0001 2019 11...
Страница 2: ...REF 2100337 0001 2019 11 CA 1 2 5L MS Bien Air Dental SA Set supplied REF CA 1 2 5L MS 1601055 001 Optional accessories REF 1600617 006 1600036 006 1600064 006 1000001 010...
Страница 3: ...ons for maintenance 9 6 1 2 Suitable maintenance products 9 6 2 Cleaning 10 6 3 Cleaning disinfection 12 6 3 1 Manual cleaning disinfection 12 6 3 2 Automatic cleaning disinfection 12 6 4 Lubrication...
Страница 4: ...d electronic equip ment Refer to the accompanying documents Recyclable materials 4 way fitting Use rubber gloves Electric powered 4 way fitting 4VLM After initial mechanical resistance tighten fully i...
Страница 5: ...elating to medical devices This medical device complies with the legislation in force 2 3 Intended use Product intended for professional use only Use in general dentistry and in dental surgery CAUTION...
Страница 6: ...n medical devices that are contaminated or potentially con taminated must comply with universal precautions in particular the wearing of personal protective equipment gloves goggles etc Pointed and sh...
Страница 7: ...2 stand ards 7 135 C 135 C 1 2 3 4 5 FIG 1 CA 1 2 5L MS 4 2 Technical data Contra angle 1 2 5 Standard coupling As per ISO standard 3964 2016 and Short Drive speed 40 000 rpm max Speed of rotation 100...
Страница 8: ...le the in strument is in operation is mandatory failure to comply with this re commendation may result in overheating and burns or product fail ure Set the water quantity for the cooling spray to at l...
Страница 9: ...those recommended by Bien Air Dental SA Using other products or parts may cause faults during operation and or void the warranty Chuck mechanism Carry out cleaning disinfection ster ilisation without...
Страница 10: ...rest of the instrument with a cloth CAUTION Do not immerse in an ultrasonic cleaner Internal cleaning with aquacare 1 Shake the Aquacare before use 2 Use the Aquacare attachment see FIG 5 step 1 3 Kee...
Страница 11: ...e Spraynet attachment see FIG 6 step 1 3 Keep the tip of the instrument point ing down and protect with an absorbent cloth press the Spraynet button down for 1 second see FIG 6 step 2 4 Clean the exte...
Страница 12: ...damage to or blockage of the in ternal components then dry the exterior surfaces with paper towels 6 3 2 Automatic cleaning disinfection CAUTION Only for device engraved with Washer disinfector Carry...
Страница 13: ...items can move around and which comply with the standards in force e g EN 868 5 Ster ilise using steam on a class B cycle as per EN 13060 ISO 17665 1 Note All Bien Air Dental SA in struments are ster...
Страница 14: ...recovery of this type of equipment 8 General information 8 1 Terms of guarantee Bien Air Dental SA grants the user a warranty covering any operating fault or material or manufacturing defect The warra...
Страница 15: ...ing information must be clearly indicated purchase date product reference and serial num ber 8 2 References Translated from original French Instructions for use 8 2 1 Set supplied see cover REF Legend...
Страница 16: ...16...
Страница 17: ...17 NOTES...
Страница 18: ...18 NOTES...
Страница 19: ...19 NOTES...
Страница 20: ...A L nggasse 60 Case postale 2500 Bienne 6 Switzerland Tel 41 0 32 344 64 64 Fax 41 0 32 344 64 91 dental bienair com Other adresses available at www bienair com REF 2100337 0001 2019 11 CA 1 2 5L MS B...