Bien-Air Dental CA 10:1 Скачать руководство пользователя страница 1

CA NOVA 1:1L
CA 1:1 L EVO15
CA 1:1

HP 1:1

CA NOVA 1:5L
CA 1:5 L EVO15
CA 1:5
CA 10:1

ENG INSTRUCTIONS FOR USE.

Other languages available on www.bienair.com/ifu

Rx Only

REF 2100294-0003/2020.03

Содержание CA 10:1

Страница 1: ...CA NOVA 1 1L CA 1 1 L EVO15 CA 1 1 HP 1 1 CA NOVA 1 5L CA 1 5 L EVO15 CA 1 5 CA 10 1 ENG INSTRUCTIONS FOR USE Other languages available on www bienair com ifu Rx Only REF 2100294 0003 2020 03...

Страница 2: ...CA 1 5 1600325 001 CA 1 5 L MS 1600690 001 Set supplied REF CA 1 1 CA NOVA 1 1L 1601137 001 CA NOVA 1 1L MS 1601136 001 CA 1 1 L EVO15 1600939 001 CA 1 1 L EVO15 MS 1600938 001 CA 1 1 L 1600384 001 C...

Страница 3: ...6 1 2 Suitable maintenance products 13 6 2 Cleaning 14 6 3 Disinfection 15 6 3 1 Manual cleaning disinfection 15 6 3 2 Automatic disinfection 15 6 4 Lubrication 17 6 4 1 Verifying cleanliness 17 6 4 2...

Страница 4: ...ht or moderate injury or damage to the device if the safety instructions are not cor rectly followed Recyclable materials Use rubber gloves After initial mechanical resistance tighten fully in the dir...

Страница 5: ...1 Dental straight hand pieces HP locking ring with 1 separated spray without light direct ratio 1 1 See the table below for a summary of your handpiece type Contra angle Light Sprays Ratio With light...

Страница 6: ...nd CA 10 1 for prophylaxis res toration and endodontics procedures l NOVA 1 5L EVO15 1 5 CA 1 5 and HP 1 1 for restoration pro cedures WARNING Any use other than that for which this device is intended...

Страница 7: ...particular the wearing of personal protective equipment gloves goggles etc Pointed and sharp instruments should be handled with great care CAUTION Any excess maintenance product lub ricant cleaning an...

Страница 8: ...4 Description 4 1 Overview FIG 1 1 Centering for the micromotor 2 Light output 3 Bur not supplied 4 Transmission ratio marking clip 5 Push button 8 FIG 1...

Страница 9: ...ured at the motor nose 8 10 Nl min Cooling air pressure 250 490 kPa Spray water flow at 200 kPa Min 60 ml min Spray air flow at 200 kPa Min 2 Nl min Recommended spray water pressure for an optimal coo...

Страница 10: ...1 for the CA 1 5 range max working dia meter 2 mm FIG 3 Shaft diameter 2 35 mm type 2 as per ISO 1797 1 max length 44 5 mm code 4 as per ISO 6360 1 for the HP 1 1 max working diameter 3 mm WARNING Fo...

Страница 11: ...e chuck system until its orientation is indexed according to the tightening 3 Check that the bur rotates freely and that it is locked by gently pushing and pulling the bur HP 1 1 FIG 5 1 Rotate the sl...

Страница 12: ...e bur is in place and rotates freely If it is blocked con tact your usual supplier or Bien Air Dental SA for repair WARNING Always ensure that the coolant supply is sufficient and adequate Failure to...

Страница 13: ...se saline to keep the device moist until it can be cleaned l Clean using manual cleaning or automated washer disinfector only do not use ultrasonic cleaner Only instruments marked with the logo can be...

Страница 14: ...Remove dirt deposits FIG 6 FIG 7 1 Clean the exterior and interior of the device under tap water at 15 C 38 C 59 F 100 F if local tap water has pH within the range 6 5 8 5 and chloride content below 1...

Страница 15: ...the device with running tap water 15 C 38 C if local tap wa ter has pH within the range 6 5 8 5 and chloride content is below 100 mg l If local tap water does not meet the requirements use de minerali...

Страница 16: ...0 C 95 C 194 F 203 F 5 10 minutes Drying 18 22 minutes CAUTION Never cool devices by rinsing them CAUTION If an automatic washer is used at the place of the washer thermo disinfector re spect the prev...

Страница 17: ...with a sterile non woven compress 6 5 Sterilisation CAUTION The quality of the sterilisation is highly dependent on how clean the in strument is Only perfectly clean instruments should be sterilised...

Страница 18: ...ronment The temperature must not exceed 55 C 131 F If the device will not be used for 7 days or more after the sterilisation extract the device from the sterilisation pouch and store it in the origina...

Страница 19: ...tic influences l Faulty air water or electrical con nections CAUTION The warranty becomes null and void if damage and its consequences result from incorrect servicing or modification by third parties...

Страница 20: ...O SERIES SET 1700795 REF Legend Ratio 1600052 001 PM 1 1 EXT SPRAY MICRO SERIES 1601138 001 CA NOVA 1 5L MS 1600691 001 CA 1 1 L MICRO SERIES SET 1700796 REF Legend Ratio 1600052 001 PM 1 1 EXT SPRAY...

Страница 21: ...60 Case postale 2500 Bienne 6 Switzerland Tel 41 0 32 344 64 64 Fax 41 0 32 344 64 91 dental bienair com Other adresses available at www bienair com REF 2100294 0003 2020 03 CA 1 1 CA 1 5 CA 10 1 EVO1...