FAULTS

CAUSES

REMEDIES

• Check power specifications

• Check power connections

• Check fuse integrity

• Main switch in wrong position

• Select correct position

• Check thermostat position

• Check thermostat operation

• Safety device (control unit, safety thermostat, etc.)

 not reset after a repair

• Press button (9) on the control panel

• The duct gives too much back pressure and

airpressure switch PA1 blocks the heater

• Reduce back pressure by straightening the duct

 or by reducing duct length

• Make sure the gas supply hose has been bled

• Check gas supply pressure

• Make sure the suction and feed grilles are

 not blocked

• Make sure the fan is turning properly

• Check the electric motor and capacitor and,

 if these are faulty, replace

• The flame sensor is not operating correctly

• Remove the flame sensor and clean

• Makes sure the suction and feed grilles

are not blocked

• Make sure the environment is well ventilated

• Make sure the warm air can exit freely

• Make sure the flow and pressure of the gas

 are not too high

• Control unit trips due to irregular operation

 of burner

• Contact After-Sales Service

• Faulty gas pressure switch

• Check the pressure switch and, if necessary,

replace

• Faulty pressure-switch PA

• Check the pressure-switch and, if necessary, 

 replace

• Faulty electronic control unit

• Check the unit and, if necessary, replace

• Faulty thermostat

• Check the thermostat and, if necessary, replace

• Foreign bodies on fan blades

• Remove foreign bodies

• Little air circulation

• Eliminate and obstacles to proper air flow

• Fan noise or vibrations

• Gas pressure switch trips due to interruption of

gas flow (gas pressure switch electric contact

 does not close during operation)

• The safety thermostat trips due to overheating of 

 the combustion chamber (the thermostat electrical 

contact does not close during operation)

• The generator fails to start

• No power supply

• Faulty operation of room thermostat

• Pressure switch PA intervention for fan malfuction

• The generator stops and the indicator light (9)

 comes on

6

Содержание GA/N 250C

Страница 1: ...HE EA AT TE ER R G GE EN NE ER RA AT TE EU UR R D D A AI IR R C CH HA AU UD D A AU U G GA AS S N NA AT TU UR RE EL L L L P P G G GA N GA N I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L M MA AN...

Страница 2: ...C Water spray nozzle shall not discharge within 6 feet of the heater D The heater is not reconnected to electrical supply until thoroughly dried Improper cleaning of the heater can cause severe perso...

Страница 3: ...NIQUE AVEC LAMPE 9 HEATING SWITCH INTERRUPTEUR CHAUFFAGE 10 ROOM THERMOSTAT PLUG PRISE THERMOSTAT D AMBIANCE 11 CONTROL LAMP LAMPE TEMOIN D ALIMENTATION 12 CABLE FASTENER FOR POWER CORD PRESSE ETOUPE...

Страница 4: ...ater is not ductable and shall not be connected to any ductwork for air distribution The room or building which is being heated must be sufficiently ventilated so that the heater has enough air to fun...

Страница 5: ...ssure regulator c if necessary to obtain the correct burner pressure value indicated in Tab I O OP PE ER RA AT TI IN NG G I IN NS ST TR RU UC CT TI IO ON NS S HEATING MODE Turning ON Make sure switch...

Страница 6: ...ot blocked Make sure the environment is well ventilated Make sure the warm air can exit freely Make sure the flow and pressure of the gas are not too high Control unit trips due to irregular operation...

Страница 7: ...T THEMOSTAT PA PRESSURE SWITCH 20 Pa RE2 DELAY STARTING RELAY opt TA ROOM THERMOSTAT PLUG IT TRANSFORMER H T CO CAPACITOR RV HEATING SWITCH RE MOTOR RELAY ST CONTROL LAMP EV GAS TRAIN MV COOLING MOTOR...

Страница 8: ...valve cfm 2 766 4 120 Phase 1 1 Voltage V 120 120 Frequency Hz 60 60 W 500 940 A 5 0 8 7 in N 16 holes x 0 079 N 16 holes x 0 102 3 4 NPT 3 4 NPT Noise level at 1 m dBA 77 74 Dimensions L x W x H in 4...

Отзывы: