11
OBSERVED FAULTS, POSSIBLE CAUSES AND REMEDIES
OBSERVED FAULT
CAUSE
REMEDY
• Check mains, it should be:
•
EK 3 A: 230V ~ 50Hz
•
EK 9 A - EK 15 A: 400V 3 ~ 50Hz
• Check proper positioning and functioning of
•
switch
• Winding of motor burnt or interrupted
• Replace motor
• Motor bearings blocked
• Replace bearings
• Wrong setting of safety device
• Check correct setting of heater control (make sure
•
selected temperature is higher than room
•
temperature)
• Defective control device
• Replace control device
• The space heaters stops and the light “c” comes on • Safety thermostat intervenes
• Identify the problem that caused the overheating.
•
In models EK 3 A and EK 9 A, the reset button is
•
placed on the machine cover, in models EK 15 A, it
•
is placed at the back.
• No electrical current
• The fan starts but there is not enough heat
• The fan doesn’t start
GB
DISPOSAL
At the end of its useful life, you have to scrap and dispose of this
product by taking it to a local differentiated waste collection center in
conformity to law.
Before scrapping, check the serial number plate on the machine: if
it has the symbol , it means that disposal is regulated by EU Direc-
tive 2003/96 (Waste Electrical and Electronic Equipment, WAEE).
The user must inquire about the local electrical and electronic
waste collection system and follow its instructions.
Illegal disposal of this product with normal domestic waste can se-
riously harm the environment and health and is subject to administra-
tive penalties.