
34
MAGIC VAPOR RA / MAGIC CAR
ENGLISH
"No water" light is on
The appliance is loading
water into the boiler (the
pump is working)
Wait for the appliance to
complete the loading of the
boiler
The "No water" light turns
on during the use of the
appliance
The boiler is empty, so the
machine is in protection
mode.
Unscrew the cap of the safety
thermostat (4) and press the
button. If the button is "soft"
it means that the thermostat
did not intervene: in this
case check for the correct
functioning of the automatic
recharge system (level probe,
pump, electric board).
Otherwise, if pressing the
button you hear a "click", it
means that the thermostat
has intervened to protect the
heater because the boiler
is empty: in this case it is
necessary to check for the
correct functioning of the
recharging system.
9. AUTOMATIC BOILER RECHARGE SYSTEM
9.1 DIAGRAM
KEY
A
BOILER PROBE +
RED
C
RELOAD HOSE –
BLACK
B
BOILER MASS –
BLACK
D
RELOAD HOSE +
RED
Tank
Electric board for automatic refill
H Probe
Boiler
Содержание BF009CAR
Страница 2: ......
Страница 19: ...19 MAGIC VAPOR RA MAGIC CAR ITALIANO 10 SCHEMA ELETTRICO...
Страница 20: ...20 MAGIC VAPOR RA MAGIC CAR ITALIANO 11 ESPLOSO...
Страница 36: ...36 MAGIC VAPOR RA MAGIC CAR ENGLISH 10 WIRED DIAGRAM...
Страница 37: ...37 MAGIC VAPOR RA MAGIC CAR ENGLISH 11 EXPLODED VIEW...
Страница 38: ...38 MAGIC VAPOR RA MAGIC CAR ENGLISH...