• Scroll through the various parameters us-
ing 12 or 13 until the LCD display shows
the code
P03
, indicating entry into “pa-
rameter P03” (Figure 5.49).
Figure 5.49
bar
RESET
•
Press 16 (Figure 5.47) to show the value
of parameter P03 on the LCD display (Fig-
ure 5.50).
Figure 5.50
bar
RESET
• By using buttons 15 or 16 it is possible to
modify the value of parameter 03 from
0
to
99
seconds.
•
Press 12 or 13 (Figure 5.47) to confirm the
value entered and return to the list of pa-
rameters (Figure 5.49).
•
Press the 17 button (Figure 5.47) to exit
“programming mode”.
5.18 Selecting re-ignition frequency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set to 1 minute (re-ignition
frequency).
This time can be programmed from a min-
imum of 0 to a maximum of 255 minutes.
•
Enter “programming mode” by holding
down buttons 17 and 18 for 5 seconds
at the same time (Figure 5.51). The code
P00
appears on the display, indicating en-
try into “parameter P00” (Figure 5.52).
Figure 5.51
12
13
15
16
17
18
Figure 5.52
bar
RESET
• Scroll through the various parameters us-
ing 12 or 13 until the LCD display shows
the code
P05
, indicating entry into “pa-