32
15
Temperature probe
15.1
Function
The Temperature probe has the function of converting
the temperature of the water in the hydraulic circuit
where it is installed into an electrical signal (resistance).
The relation between temperature and electrical resis-
tance is stated in Fig. 60.
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
9000
9500
10000
10500
11000
11500
12000
12500
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
W
° C
Fig. 60
On the boiler there are two Temperature probes. One
on the output of the primary heat exchanger (c.h. Tem-
perature probe)
A
in Fig. 61 and Fig. 62; one on its
input, before the pump (d.h.w. Temperature probe)
B
in
Fig. 61 and Fig. 63.
A
c.h.
flow
c.h.
return
d.h.w.
inlet
d.h.w.
outlet
B
Fig. 61
15.2
Checks
n
Temperature---resistance relationship
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
Disconnect the cable from the Temperature probe.
Measure the temperature of the brass group where the
Temperature probe is located and check the electrical
resistance according to the graph in Fig. 60.
15.3
Removal
Warning: isolate the boiler from the mains
electricity supply before removing any
covering or component.
Refer to Fig. 62 for the c.h. Temperature probe
and to Fig. 63 for the d.h.w. Temperature probe.
1
To remove the Temperature probes remove the
front and right hand side panels of the case.
2
Empty the primary circuit of the boiler.
3
Remove the electric connector of the Tempera-
ture probe and unscrew it.
4
Reassemble the Temperature probe carrying out
the removal operations in reverse order.
A
Fig. 62
B
Fig. 63
Содержание M90E.24S
Страница 2: ......
Страница 12: ...Diagrams 10 ...
Страница 41: ...Safety thermostat 39 ...
Страница 43: ...Short spare parts list 41 1 2 6 4 5 7 3 8 15 18 12 13 20 21 22 23 25 26 14 16 24 17 19 9 10 11 9 ...
Страница 44: ... 1796209165 17962 0916 5 1704 44A4 UK ...