background image

 

unvented

 

hot

 

water

 

cylinders

  

installation

 

and

 

maintenance

 

instructions

 

Page

 

8

 

/

 

20

 

SAFETY

 

VALVE

 

CHECKS

  

Any

 

sign

 

of

 

water

 

coming

 

from

 

either

 

the

 

expansion

 

relief

 

valve

 

or

 

the

 

temperature/pressure

 

relief

 

valve

 

during

 

heat

up

 

indicates

 

a

 

problem.

 

Next

 

hold

 

both

 

of

 

these

 

safety

 

valves

 

fully

 

open,

 

allowing

 

as

 

much

 

water

 

as

 

possible

 

to

 

flow

 

through

 

the

 

tundish.

 

Check

 

that

 

your

 

discharge

 

pipework

 

is

 

free

 

from

 

debris

 

and

 

is

 

carrying

 

the

 

water

 

away

 

to

 

waste

 

efficiently.

 

Release

 

the

 

valves

 

and

 

check

 

that

 

they

 

reseat

 

properly.

  

 
 

SERVICING

  

GENERAL

 

Servicing

 

should

 

only

 

be

 

carried

 

out

 

by

 

competent

 

installers

 

and

 

any

 

spare

 

parts

 

used

 

must

 

be

 

purchased

 

from

 

BIASI

 

Cylinders.

 

NEVER

 

bypass

 

any

 

safety

 

devices

 

or

 

operate

 

the

 

unit

 

without

 

them

 

being

 

fully

 

operational.

 

  

DRAINING

 

Switch

 

the

 

electrical

 

power

 

off

 

(important

 

to

 

avoid

 

damage

 

to

 

element).

 

Isolate

 

boiler

 

from

 

the

 

unit.

 

Turn

 

off

 

the

 

cold

 

water

 

supply

 

valve.

 

Open

 

hot

 

water

 

tap.

 

Open

 

the

 

drain

 

valve.

 

The

 

unit

 

will

 

drain.

 

WARNING:

 

WATER

 

DRAINED

 

OFF

 

MAY

 

BE

 

VERY

 

HOT!

 

 

 

ANNUAL

 

MAINTENANCE

 

The

 

water

 

heaters

 

require

 

annual

 

servicing

 

in

 

order

 

to

 

ensure

 

safe

 

working

 

and

 

optimum

 

performance.

 

It

 

is

 

essential

 

that

 

the

 

following

 

checks

 

are

 

performed

 

by

 

a

 

competent

 

installer

 

on

 

an

 

annual

 

basis.

 

This

 

is

 

commonly

 

done

 

at

 

the

 

same

 

time

 

as

 

the

 

annual

 

boiler

 

service.

  

1)

 

Twist

 

the

 

cap

 

of

 

the

 

expansion

 

relief

 

valve

 

on

 

the

 

inlet

 

control

 

set

 

and

 

allow

 

water

 

to

 

flow

 

for

 

5

 

seconds.

 

Release

 

and

 

make

 

sure

 

it

 

resets

 

correctly.

 

Repeat

 

with

 

the

 

pressure

 

/

 

temperature

 

relief

 

valve.

 

In

 

both

 

cases

 

check

 

that

 

the

 

discharge

 

pipework

 

is

 

carrying

 

the

 

water

 

away

 

adequately.

 

If

 

not,

 

check

 

for

 

blockages

 

etc.

 

and

 

clear.

  

WARNING:

 

THE

 

WATER

 

DISCHARGED

 

MAY

 

BE

 

VERY

 

HOT!

  

2)

 

Check

 

that

 

any

 

immersion

 

heaters

 

fi

tted

 

are

 

working

 

correctly

 

and

 

that

 

they

 

are

 

controlling

 

the

 

water

 

at

 

a

 

temperature

 

between

 

55°C

 

and

 

65°C.

  

3)

 

Check

 

the

 

pressure

 

in

 

the

 

expansion

 

vessel

 

is

 

charged

 

to

 

3

 

bar.

 

Turn

 

off

 

the

 

water

 

supply

 

to

 

the

 

unit

 

and

 

open

 

a

 

hot

 

tap

 

fi

rst.

 

The

 

air

 

valve

 

on

 

expansion

 

vessel

 

is

 

a

 

Schrader

 

(car

 

tyre)

 

type.

 

Air

 

or

 

CO2

 

may

 

be

 

used

 

to

 

charge

 

the

 

expansion

 

vessel.

  

4)

 

Unscrew

 

the

 

head

 

on

 

the

 

inlet

 

control

 

set

 

and

 

clean

 

the

 

mesh

 

filter

 

within.

  

5)

 

The

 

Benchmark

 

Log

 

Book

 

supplied

 

with

 

this

 

unit

 

should

 

be

 

updated

 

at

 

each

 

service.

  

 

YOUR

 

GUARANTEE

 

MAY

 

BE

 

VOID

 

WITHOUT

 

PROOF

 

OF

 

ANNUAL

 

SERVICING

 

 
 

SPARE

 

PARTS

  

A

 

full

 

range

 

of

 

spare

 

parts

 

is

 

available.

  

 

 

 

Содержание 125DI

Страница 1: ...vented cylinders are a controlled service as defined in the latest edition of the building regulations and should only be fitted by a competent person The relevant regulations are England and Wales Bu...

Страница 2: ...pressure drop which gives fantastic performance in all areas with great improvements in areas with poor water pressure KIWA approved for compliance with the Water Supply Water Fittings Regulations 199...

Страница 3: ...old services simultaneously The water heater itself operates at a pressure of 3 bar controlled by the inlet control set and is capable of delivering over 50 litres per minute The high quality inlet co...

Страница 4: ...cket provided and connect to the inlet control set with the flexible hose provided Ensure that the top of the vessel is accessible for servicing PRIMARY COIL CONNECTIONS Connect the primary connection...

Страница 5: ...fety device unless its total equivalent hydraulic resistance exceeds that of a straight pipe 9m long i e discharge pipes between 9m and 18m equivalent resistance length should be at least two sizes la...

Страница 6: ...scharge takes place WORKED EXAMPLE The example below is for G1 2 temperature relief valve with a discharge pipe D2 having 4 No elbows and length of 7m from the tundish to the point of discharge From T...

Страница 7: ...erilisation liquid switch on the power to the immersion heaters and allow the unit to start to heat The immersion heater is supplied preset at 55 C Turning fully to sets to approx 65 C INDIRECT UNITS...

Страница 8: ...n order to ensure safe working and optimum performance It is essential that the following checks are performed by a competent installer on an annual basis This is commonly done at the same time as the...

Страница 9: ...cloudy water Oxygenated water Water from any pressurized system will release oxygen bubbles when flowing The bubbles will settle out No hot water flow Cold main off Check and open stopcock Stainer bl...

Страница 10: ...t part fails within the guarantee period we will send you a new one without any upfront charge Credit card details may be taken to prevent fraud We ask you to post the faulty part back to us within on...

Страница 11: ...1 241 250 1825 1592 1167 287 272 1427 49 299 300 2105 1872 1242 287 272 1667 56 356 INDIRECT Top view CAPACITY L A mm B mm C mm D mm E mm F mm G mm H mm I mm WEIGHT Empty kg WEIGHT Full kg 125 1045 81...

Страница 12: ...e see pages 13 and 14 SOLAR UNVENTED INDIRECT TWIN COIL CYLINDER With either format it is essential the overall installation meets all current legislation including in particular the high limit isolat...

Страница 13: ...tions Page 13 20 TYPICAL SCHEMATIC WIRING DIAGRAM SOLAR HIGH LIMIT CONTROL These schematic wiring diagrams depict an IMIT high limit control stat and the connections are numbered accordingly Where an...

Страница 14: ...67 350 272 290 525 760 1427 1574 57 303 300 2105 1872 1242 350 272 290 525 760 1667 1854 64 360 SOLAR INDIRECT Top view CAPACITY L A mm B mm C mm D mm E mm F mm G mm H mm I mm J mm K mm L mm WEIGHT Em...

Страница 15: ...ity of water can be heated to an acceptable temperature by the householders traditional heat source of gas oil or electricity The Domestic Heating Compliance Guide document L1A and L1B provides excell...

Страница 16: ...e Depletion Potential of Zero and a Global Warming CASEWORK Electrostatically painted steel ANODE None fitted none required EXPANSION VESSEL CONTROL SETTINGS Pressure Reducing Valve 3 Bar Expansion Re...

Страница 17: ...MA ANUFACTURE instal ED by ww unven lation and m ww videira pt nted hot wa maintenance ater cylinders e instructions s s Page 1 17 20...

Страница 18: ...instal unven lation and m nted hot wa maintenance ater cylinders e instructions s s Page 1 18 20...

Страница 19: ...unvented hot water cylinders installation and maintenance instructions Page 19 20 NOTES...

Страница 20: ...Biasi UK Ltd Commercial Road Leamore Enterprise Park Walsall WS2 7NQ Telephone number 01922 714600 Fax number 01922 714626 Company website www biasi co uk...

Отзывы: